Loading…

Hyperintensity of Cerebrospinal Fluid on T2-Weighted Fluid-Attenuated Inversion Recovery Magnetic Resonance Imaging Caused by High Inspired Oxygen Fraction

In veterinary medicine, patients undergo magnetic resonance imaging (MRI) under general anesthesia to enable acquisition of artifact-free images. The fraction of inspired oxygen (FiO ) ranges between 30 and 95%. In humans, a high FiO is associated with incomplete signal suppression of peripheral cer...

Full description

Saved in:
Bibliographic Details
Published in:Frontiers in veterinary science 2017-12, Vol.4, p.219-219
Main Authors: Moioli, Melania, Levionnois, Olivier, Stein, Veronika M, Schüpbach, Gertraud, Schmidhalter, Marta, Schweizer-Gorgas, Daniela
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c528t-ec7a30e742c35f34c560e08ae8dfdca3c0d87dfe53c6128e75cd8654737db4863
cites cdi_FETCH-LOGICAL-c528t-ec7a30e742c35f34c560e08ae8dfdca3c0d87dfe53c6128e75cd8654737db4863
container_end_page 219
container_issue
container_start_page 219
container_title Frontiers in veterinary science
container_volume 4
creator Moioli, Melania
Levionnois, Olivier
Stein, Veronika M
Schüpbach, Gertraud
Schmidhalter, Marta
Schweizer-Gorgas, Daniela
description In veterinary medicine, patients undergo magnetic resonance imaging (MRI) under general anesthesia to enable acquisition of artifact-free images. The fraction of inspired oxygen (FiO ) ranges between 30 and 95%. In humans, a high FiO is associated with incomplete signal suppression of peripheral cerebrospinal fluid (CSF) spaces on T2-weighted fluid-attenuated inversion recovery (T2w-FLAIR) sequences. The influence of FiO on T2w-FLAIR images remains unreported in small animals. The aim of this prospective study was to investigate whether a high FiO is associated with hyperintensity in peripheral CSF spaces on T2w-FLAIR images in dogs and cats. Client-owned patients undergoing brain MRI were prospectively enrolled. Animals with brain parenchymal abnormalities and/or meningeal contrast enhancement on MRI images and/or abnormal CSF analysis were excluded. Consequently, twelve patients were enrolled. Anesthesia was maintained by isoflurane 0.5-1 minimal alveolar concentration in 30% oxygen. After acquisition of transverse and dorsal T2w-FLAIR images, the FiO was increased to 95%. The T2w-FLAIR sequences were then repeated after 40 min. Arterial blood gas analysis was performed in six patients at the same time as T2w-FLAIR sequence acquisition. Plot profiles of the signal intensity (SI) from CSF spaces of three cerebral sulci and adjacent gray and white matter were generated. SI ratios of CSF space and white matter were compared between the T2w-FLAIR images with 30 and 95% FiO . An observer blinded to the FiO , subjectively evaluated the SI of peripheral CSF spaces on T2w-FLAIR images as high or low. There was significant difference in the partial pressure of oxygen between the two arterial samples (  
doi_str_mv 10.3389/fvets.2017.00219
format article
fullrecord <record><control><sourceid>proquest_doaj_</sourceid><recordid>TN_cdi_doaj_primary_oai_doaj_org_article_8940943d6fbb43df8616e8814aa68571</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><doaj_id>oai_doaj_org_article_8940943d6fbb43df8616e8814aa68571</doaj_id><sourcerecordid>1989572794</sourcerecordid><originalsourceid>FETCH-LOGICAL-c528t-ec7a30e742c35f34c560e08ae8dfdca3c0d87dfe53c6128e75cd8654737db4863</originalsourceid><addsrcrecordid>eNpVkktr3DAUhU1pacI0-66Kl914qoetx6YQhk5nICVQUroUsnTtKHikqWQP8W_pn61mJg3J6oqje76rxymKjxgtKRXyS3eAMS0JwnyJEMHyTXFJiOQV5ky-fbG-KK5SekAI4abmVKD3xQWRlDDZ0Mvi72beQ3R-BJ_cOJehK1cQoY0h7Z3XQ7keJmfL4Ms7Uv0G19-PYM9idT1m16SPwtYfICaX236CCXk9lz9072F0JispeO0NlNud7p3vy5WeUja1c7nJwGzOs2IWbh_nHny5jtqMmfWheNfpIcHVU10Uv9bf7lab6ub2-3Z1fVOZhoixAsM1RcBrYmjT0do0DAESGoTtrNHUICu47aChhmEigDfGCnZ8C27bWjC6KLZnrg36Qe2j2-k4q6CdOgkh9krHfJMBlJA1kjW1rGvbXDrBMAMhcK01Ew3HmfX1zNpP7Q6sAT9GPbyCvt7x7l714aAaXmOGRAZ8fgLE8GeCNKqdSwaGQXsIU1JYCtlwwvMpFgU6t5r8WylC9zwGI3WMiDpFRB0jok4RyZZPL4_3bPgfCPoP8JG75g</addsrcrecordid><sourcetype>Open Website</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1989572794</pqid></control><display><type>article</type><title>Hyperintensity of Cerebrospinal Fluid on T2-Weighted Fluid-Attenuated Inversion Recovery Magnetic Resonance Imaging Caused by High Inspired Oxygen Fraction</title><source>PubMed Central</source><creator>Moioli, Melania ; Levionnois, Olivier ; Stein, Veronika M ; Schüpbach, Gertraud ; Schmidhalter, Marta ; Schweizer-Gorgas, Daniela</creator><creatorcontrib>Moioli, Melania ; Levionnois, Olivier ; Stein, Veronika M ; Schüpbach, Gertraud ; Schmidhalter, Marta ; Schweizer-Gorgas, Daniela</creatorcontrib><description>In veterinary medicine, patients undergo magnetic resonance imaging (MRI) under general anesthesia to enable acquisition of artifact-free images. The fraction of inspired oxygen (FiO ) ranges between 30 and 95%. In humans, a high FiO is associated with incomplete signal suppression of peripheral cerebrospinal fluid (CSF) spaces on T2-weighted fluid-attenuated inversion recovery (T2w-FLAIR) sequences. The influence of FiO on T2w-FLAIR images remains unreported in small animals. The aim of this prospective study was to investigate whether a high FiO is associated with hyperintensity in peripheral CSF spaces on T2w-FLAIR images in dogs and cats. Client-owned patients undergoing brain MRI were prospectively enrolled. Animals with brain parenchymal abnormalities and/or meningeal contrast enhancement on MRI images and/or abnormal CSF analysis were excluded. Consequently, twelve patients were enrolled. Anesthesia was maintained by isoflurane 0.5-1 minimal alveolar concentration in 30% oxygen. After acquisition of transverse and dorsal T2w-FLAIR images, the FiO was increased to 95%. The T2w-FLAIR sequences were then repeated after 40 min. Arterial blood gas analysis was performed in six patients at the same time as T2w-FLAIR sequence acquisition. Plot profiles of the signal intensity (SI) from CSF spaces of three cerebral sulci and adjacent gray and white matter were generated. SI ratios of CSF space and white matter were compared between the T2w-FLAIR images with 30 and 95% FiO . An observer blinded to the FiO , subjectively evaluated the SI of peripheral CSF spaces on T2w-FLAIR images as high or low. There was significant difference in the partial pressure of oxygen between the two arterial samples (  &lt; 0.001). The SI ratios obtained from the T2w-FLAIR images with 95% FiO were significantly higher compared with those obtained from the T2w-FLAIR images with 30% FiO (  &lt; 0.05). The peripheral CSF spaces were subjectively considered hyperintense in 11 of 12 cases on T2w-FLAIR images with 95% FiO (  &lt; 0.005). A clear difference in SI, dependent on the FiO was seen in the peripheral CSF spaces on T2w-FLAIR images. In conclusion, the influence of FiO must be considered when differentiating pathological and normal CSF spaces on T2w-FLAIR images in dogs and cats.</description><identifier>ISSN: 2297-1769</identifier><identifier>EISSN: 2297-1769</identifier><identifier>DOI: 10.3389/fvets.2017.00219</identifier><identifier>PMID: 29326953</identifier><language>eng</language><publisher>Switzerland: Frontiers Media S.A</publisher><subject>brain ; cerebrospinal fluid ; dog ; magnetic resonance imaging ; oxygen ; T2-weighted fluid-attenuated inversion recovery ; Veterinary Science</subject><ispartof>Frontiers in veterinary science, 2017-12, Vol.4, p.219-219</ispartof><rights>Copyright © 2017 Moioli, Levionnois, Stein, Schüpbach, Schmidhalter and Schweizer-Gorgas. 2017 Moioli, Levionnois, Stein, Schüpbach, Schmidhalter and Schweizer-Gorgas</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c528t-ec7a30e742c35f34c560e08ae8dfdca3c0d87dfe53c6128e75cd8654737db4863</citedby><cites>FETCH-LOGICAL-c528t-ec7a30e742c35f34c560e08ae8dfdca3c0d87dfe53c6128e75cd8654737db4863</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC5741608/pdf/$$EPDF$$P50$$Gpubmedcentral$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC5741608/$$EHTML$$P50$$Gpubmedcentral$$Hfree_for_read</linktohtml><link.rule.ids>230,314,727,780,784,885,27924,27925,53791,53793</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/29326953$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Moioli, Melania</creatorcontrib><creatorcontrib>Levionnois, Olivier</creatorcontrib><creatorcontrib>Stein, Veronika M</creatorcontrib><creatorcontrib>Schüpbach, Gertraud</creatorcontrib><creatorcontrib>Schmidhalter, Marta</creatorcontrib><creatorcontrib>Schweizer-Gorgas, Daniela</creatorcontrib><title>Hyperintensity of Cerebrospinal Fluid on T2-Weighted Fluid-Attenuated Inversion Recovery Magnetic Resonance Imaging Caused by High Inspired Oxygen Fraction</title><title>Frontiers in veterinary science</title><addtitle>Front Vet Sci</addtitle><description>In veterinary medicine, patients undergo magnetic resonance imaging (MRI) under general anesthesia to enable acquisition of artifact-free images. The fraction of inspired oxygen (FiO ) ranges between 30 and 95%. In humans, a high FiO is associated with incomplete signal suppression of peripheral cerebrospinal fluid (CSF) spaces on T2-weighted fluid-attenuated inversion recovery (T2w-FLAIR) sequences. The influence of FiO on T2w-FLAIR images remains unreported in small animals. The aim of this prospective study was to investigate whether a high FiO is associated with hyperintensity in peripheral CSF spaces on T2w-FLAIR images in dogs and cats. Client-owned patients undergoing brain MRI were prospectively enrolled. Animals with brain parenchymal abnormalities and/or meningeal contrast enhancement on MRI images and/or abnormal CSF analysis were excluded. Consequently, twelve patients were enrolled. Anesthesia was maintained by isoflurane 0.5-1 minimal alveolar concentration in 30% oxygen. After acquisition of transverse and dorsal T2w-FLAIR images, the FiO was increased to 95%. The T2w-FLAIR sequences were then repeated after 40 min. Arterial blood gas analysis was performed in six patients at the same time as T2w-FLAIR sequence acquisition. Plot profiles of the signal intensity (SI) from CSF spaces of three cerebral sulci and adjacent gray and white matter were generated. SI ratios of CSF space and white matter were compared between the T2w-FLAIR images with 30 and 95% FiO . An observer blinded to the FiO , subjectively evaluated the SI of peripheral CSF spaces on T2w-FLAIR images as high or low. There was significant difference in the partial pressure of oxygen between the two arterial samples (  &lt; 0.001). The SI ratios obtained from the T2w-FLAIR images with 95% FiO were significantly higher compared with those obtained from the T2w-FLAIR images with 30% FiO (  &lt; 0.05). The peripheral CSF spaces were subjectively considered hyperintense in 11 of 12 cases on T2w-FLAIR images with 95% FiO (  &lt; 0.005). A clear difference in SI, dependent on the FiO was seen in the peripheral CSF spaces on T2w-FLAIR images. In conclusion, the influence of FiO must be considered when differentiating pathological and normal CSF spaces on T2w-FLAIR images in dogs and cats.</description><subject>brain</subject><subject>cerebrospinal fluid</subject><subject>dog</subject><subject>magnetic resonance imaging</subject><subject>oxygen</subject><subject>T2-weighted fluid-attenuated inversion recovery</subject><subject>Veterinary Science</subject><issn>2297-1769</issn><issn>2297-1769</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2017</creationdate><recordtype>article</recordtype><sourceid>DOA</sourceid><recordid>eNpVkktr3DAUhU1pacI0-66Kl914qoetx6YQhk5nICVQUroUsnTtKHikqWQP8W_pn61mJg3J6oqje76rxymKjxgtKRXyS3eAMS0JwnyJEMHyTXFJiOQV5ky-fbG-KK5SekAI4abmVKD3xQWRlDDZ0Mvi72beQ3R-BJ_cOJehK1cQoY0h7Z3XQ7keJmfL4Ms7Uv0G19-PYM9idT1m16SPwtYfICaX236CCXk9lz9072F0JispeO0NlNud7p3vy5WeUja1c7nJwGzOs2IWbh_nHny5jtqMmfWheNfpIcHVU10Uv9bf7lab6ub2-3Z1fVOZhoixAsM1RcBrYmjT0do0DAESGoTtrNHUICu47aChhmEigDfGCnZ8C27bWjC6KLZnrg36Qe2j2-k4q6CdOgkh9krHfJMBlJA1kjW1rGvbXDrBMAMhcK01Ew3HmfX1zNpP7Q6sAT9GPbyCvt7x7l714aAaXmOGRAZ8fgLE8GeCNKqdSwaGQXsIU1JYCtlwwvMpFgU6t5r8WylC9zwGI3WMiDpFRB0jok4RyZZPL4_3bPgfCPoP8JG75g</recordid><startdate>20171218</startdate><enddate>20171218</enddate><creator>Moioli, Melania</creator><creator>Levionnois, Olivier</creator><creator>Stein, Veronika M</creator><creator>Schüpbach, Gertraud</creator><creator>Schmidhalter, Marta</creator><creator>Schweizer-Gorgas, Daniela</creator><general>Frontiers Media S.A</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>5PM</scope><scope>DOA</scope></search><sort><creationdate>20171218</creationdate><title>Hyperintensity of Cerebrospinal Fluid on T2-Weighted Fluid-Attenuated Inversion Recovery Magnetic Resonance Imaging Caused by High Inspired Oxygen Fraction</title><author>Moioli, Melania ; Levionnois, Olivier ; Stein, Veronika M ; Schüpbach, Gertraud ; Schmidhalter, Marta ; Schweizer-Gorgas, Daniela</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c528t-ec7a30e742c35f34c560e08ae8dfdca3c0d87dfe53c6128e75cd8654737db4863</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2017</creationdate><topic>brain</topic><topic>cerebrospinal fluid</topic><topic>dog</topic><topic>magnetic resonance imaging</topic><topic>oxygen</topic><topic>T2-weighted fluid-attenuated inversion recovery</topic><topic>Veterinary Science</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Moioli, Melania</creatorcontrib><creatorcontrib>Levionnois, Olivier</creatorcontrib><creatorcontrib>Stein, Veronika M</creatorcontrib><creatorcontrib>Schüpbach, Gertraud</creatorcontrib><creatorcontrib>Schmidhalter, Marta</creatorcontrib><creatorcontrib>Schweizer-Gorgas, Daniela</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><collection>DOAJ Directory of Open Access Journals</collection><jtitle>Frontiers in veterinary science</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Moioli, Melania</au><au>Levionnois, Olivier</au><au>Stein, Veronika M</au><au>Schüpbach, Gertraud</au><au>Schmidhalter, Marta</au><au>Schweizer-Gorgas, Daniela</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Hyperintensity of Cerebrospinal Fluid on T2-Weighted Fluid-Attenuated Inversion Recovery Magnetic Resonance Imaging Caused by High Inspired Oxygen Fraction</atitle><jtitle>Frontiers in veterinary science</jtitle><addtitle>Front Vet Sci</addtitle><date>2017-12-18</date><risdate>2017</risdate><volume>4</volume><spage>219</spage><epage>219</epage><pages>219-219</pages><issn>2297-1769</issn><eissn>2297-1769</eissn><abstract>In veterinary medicine, patients undergo magnetic resonance imaging (MRI) under general anesthesia to enable acquisition of artifact-free images. The fraction of inspired oxygen (FiO ) ranges between 30 and 95%. In humans, a high FiO is associated with incomplete signal suppression of peripheral cerebrospinal fluid (CSF) spaces on T2-weighted fluid-attenuated inversion recovery (T2w-FLAIR) sequences. The influence of FiO on T2w-FLAIR images remains unreported in small animals. The aim of this prospective study was to investigate whether a high FiO is associated with hyperintensity in peripheral CSF spaces on T2w-FLAIR images in dogs and cats. Client-owned patients undergoing brain MRI were prospectively enrolled. Animals with brain parenchymal abnormalities and/or meningeal contrast enhancement on MRI images and/or abnormal CSF analysis were excluded. Consequently, twelve patients were enrolled. Anesthesia was maintained by isoflurane 0.5-1 minimal alveolar concentration in 30% oxygen. After acquisition of transverse and dorsal T2w-FLAIR images, the FiO was increased to 95%. The T2w-FLAIR sequences were then repeated after 40 min. Arterial blood gas analysis was performed in six patients at the same time as T2w-FLAIR sequence acquisition. Plot profiles of the signal intensity (SI) from CSF spaces of three cerebral sulci and adjacent gray and white matter were generated. SI ratios of CSF space and white matter were compared between the T2w-FLAIR images with 30 and 95% FiO . An observer blinded to the FiO , subjectively evaluated the SI of peripheral CSF spaces on T2w-FLAIR images as high or low. There was significant difference in the partial pressure of oxygen between the two arterial samples (  &lt; 0.001). The SI ratios obtained from the T2w-FLAIR images with 95% FiO were significantly higher compared with those obtained from the T2w-FLAIR images with 30% FiO (  &lt; 0.05). The peripheral CSF spaces were subjectively considered hyperintense in 11 of 12 cases on T2w-FLAIR images with 95% FiO (  &lt; 0.005). A clear difference in SI, dependent on the FiO was seen in the peripheral CSF spaces on T2w-FLAIR images. In conclusion, the influence of FiO must be considered when differentiating pathological and normal CSF spaces on T2w-FLAIR images in dogs and cats.</abstract><cop>Switzerland</cop><pub>Frontiers Media S.A</pub><pmid>29326953</pmid><doi>10.3389/fvets.2017.00219</doi><tpages>1</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 2297-1769
ispartof Frontiers in veterinary science, 2017-12, Vol.4, p.219-219
issn 2297-1769
2297-1769
language eng
recordid cdi_doaj_primary_oai_doaj_org_article_8940943d6fbb43df8616e8814aa68571
source PubMed Central
subjects brain
cerebrospinal fluid
dog
magnetic resonance imaging
oxygen
T2-weighted fluid-attenuated inversion recovery
Veterinary Science
title Hyperintensity of Cerebrospinal Fluid on T2-Weighted Fluid-Attenuated Inversion Recovery Magnetic Resonance Imaging Caused by High Inspired Oxygen Fraction
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-03T09%3A21%3A48IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_doaj_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Hyperintensity%20of%20Cerebrospinal%20Fluid%20on%20T2-Weighted%20Fluid-Attenuated%20Inversion%20Recovery%20Magnetic%20Resonance%20Imaging%20Caused%20by%20High%20Inspired%20Oxygen%20Fraction&rft.jtitle=Frontiers%20in%20veterinary%20science&rft.au=Moioli,%20Melania&rft.date=2017-12-18&rft.volume=4&rft.spage=219&rft.epage=219&rft.pages=219-219&rft.issn=2297-1769&rft.eissn=2297-1769&rft_id=info:doi/10.3389/fvets.2017.00219&rft_dat=%3Cproquest_doaj_%3E1989572794%3C/proquest_doaj_%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c528t-ec7a30e742c35f34c560e08ae8dfdca3c0d87dfe53c6128e75cd8654737db4863%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=1989572794&rft_id=info:pmid/29326953&rfr_iscdi=true