Loading…

Impact of a Combined Continuous Glucose Monitoring–Digital Health Solution on Glucose Metrics and Self-Management Behavior for Adults With Type 2 Diabetes: Real-World, Observational Study

Background:The BlueStar (Welldoc) digital health solution for people with diabetes incorporates data from multiple devices and generates coaching messages using artificial intelligence. The BlueStar app syncs glucose data from the G6 (Dexcom) real-time continuous glucose monitoring (RT-CGM) system,...

Full description

Saved in:
Bibliographic Details
Published in:JMIR diabetes 2023-09, Vol.8, p.e47638-e47638
Main Authors: Kumbara, Abhimanyu B, Iyer, Anand K, Green, Courtney R, Jepson, Lauren H, Leone, Keri, Layne, Jennifer E, Shomali, Mansur
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Background:The BlueStar (Welldoc) digital health solution for people with diabetes incorporates data from multiple devices and generates coaching messages using artificial intelligence. The BlueStar app syncs glucose data from the G6 (Dexcom) real-time continuous glucose monitoring (RT-CGM) system, which provides a glucose measurement every 5 minutes.Objective:The objective of this real-world study of people with type 2 diabetes (T2D) using the digital health solution and RT-CGM was to evaluate change in glycemic control and engagement with the program over 3 months.Methods:Participants were current or former enrollees in an employer-sponsored health plan, were aged 18 years or older, had a T2D diagnosis, and were not using prandial insulin. Outcomes included CGM-based glycemic metrics and engagement with the BlueStar app, including logging medications taken, exercise, food details, blood pressure, weight, and hours of sleep.Results:Participants in the program that met our analysis criteria (n=52) were aged a mean of 53 (SD 9) years; 37% (19/52) were female and approximately 50% (25/52) were taking diabetes medications. The RT-CGM system was worn 90% (SD 8%) of the time over 3 months. Among individuals with suboptimal glycemic control at baseline, defined as mean glucose >180 mg/dL, clinically meaningful improvements in glycemic control were observed, including reductions in a glucose management indicator (–0.8 percentage points), time above range 181-250 mg/dL (–4.4 percentage points) and time above range >250 mg/dL (–14 percentage points; all P
ISSN:2371-4379