Slurry nebulization ICP-OES for the determination of Cu, Fe, Mg, Mn and Zn in bovine liver

A method that involves analysis of bovine liver by slurry nebulization and ICP-OES has been developed. This method permits rapid and accurate determination of Cu, Fe, Mg, Mn and Zn in bovine liver. Aliquots of freeze-dried and powdered bovine liver sample were dispersed in 2.0 M HNO3 and sonicated t...

Full description

Saved in:
Bibliographic Details
Published in:Bulletin of the Chemical Society of Ethiopia 2008-12, Vol.22 (3), p.313-321
Main Authors: Ntebogeng S. Mokgalaka, Taddese Wondimu, Robert I. McCrindle
Format: Article
Language:English
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites
container_end_page 321
container_issue 3
container_start_page 313
container_title Bulletin of the Chemical Society of Ethiopia
container_volume 22
creator Ntebogeng S. Mokgalaka
Taddese Wondimu
Robert I. McCrindle
description A method that involves analysis of bovine liver by slurry nebulization and ICP-OES has been developed. This method permits rapid and accurate determination of Cu, Fe, Mg, Mn and Zn in bovine liver. Aliquots of freeze-dried and powdered bovine liver sample were dispersed in 2.0 M HNO3 and sonicated to homogenize the resulting slurries. Bovine liver samples were also microwave digested or subjected to aqueous extraction for comparison of analytical results. Concentrations of Cu, Fe, Mg, Mn and Zn in aqueous slurries, the digests, and aqueous extracts were determined by the ICP-OES using external calibration curves. A student’s t-test showed that the results obtained using the slurry method were in good agreement at 95 % confidence level (CL) with those of microwave digestion or aqueous extraction techniques, except for Fe. To check the accuracy and precision of the slurry method, a bovine liver CRM was analyzed and good agreement was achieved with the certified values at 95 % CL. The results demonstrate inefficiency of aqueous extraction technique for complete removal of Fe in bovine liver sample.
format article
fullrecord <record><control><sourceid>doaj</sourceid><recordid>TN_cdi_doaj_primary_oai_doaj_org_article_8a69821b6c7a410780b76887b4c6ca2d</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><doaj_id>oai_doaj_org_article_8a69821b6c7a410780b76887b4c6ca2d</doaj_id><sourcerecordid>oai_doaj_org_article_8a69821b6c7a410780b76887b4c6ca2d</sourcerecordid><originalsourceid>FETCH-LOGICAL-d221t-a16053e66eecd5b24651a7f2afbe40ef249ffc1e6d05749b86af8f3741deca663</originalsourceid><addsrcrecordid>eNotjNFKwzAYhYsoOKfvkAdYIUnTJL2UsulgY8IUZDflT_JnZnSJZN1gPr3DeXE4H-eDc1OMmOKy1JR93l6YMlZWDRf3xcPhsKOU00rVo2Kz7o85n0lEc-zDDwwhRTJv38rVdE18ymT4QuJwwLwP8WqTJ-1xQmY4IcvtJZFAdGQTSYjEpFOISPpwwvxY3HnoD_j03-PiYzZ9b1_Lxepl3j4vSsc5G0pgktYVSoloXW24kDUD5Tl4g4Ki56Lx3jKUjtZKNEZL8NpXSjCHFqSsxsX8-usS7LrvHPaQz12C0P0NKW87yEOwPXYaZKM5M9IqEIwqTY2SWisjrLTAXfULQQRa2A</addsrcrecordid><sourcetype>Open Website</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Slurry nebulization ICP-OES for the determination of Cu, Fe, Mg, Mn and Zn in bovine liver</title><source>Free Full-Text Journals in Chemistry</source><creator>Ntebogeng S. Mokgalaka ; Taddese Wondimu ; Robert I. McCrindle</creator><creatorcontrib>Ntebogeng S. Mokgalaka ; Taddese Wondimu ; Robert I. McCrindle</creatorcontrib><description>A method that involves analysis of bovine liver by slurry nebulization and ICP-OES has been developed. This method permits rapid and accurate determination of Cu, Fe, Mg, Mn and Zn in bovine liver. Aliquots of freeze-dried and powdered bovine liver sample were dispersed in 2.0 M HNO3 and sonicated to homogenize the resulting slurries. Bovine liver samples were also microwave digested or subjected to aqueous extraction for comparison of analytical results. Concentrations of Cu, Fe, Mg, Mn and Zn in aqueous slurries, the digests, and aqueous extracts were determined by the ICP-OES using external calibration curves. A student’s t-test showed that the results obtained using the slurry method were in good agreement at 95 % confidence level (CL) with those of microwave digestion or aqueous extraction techniques, except for Fe. To check the accuracy and precision of the slurry method, a bovine liver CRM was analyzed and good agreement was achieved with the certified values at 95 % CL. The results demonstrate inefficiency of aqueous extraction technique for complete removal of Fe in bovine liver sample.</description><identifier>ISSN: 1011-3924</identifier><identifier>EISSN: 1726-801X</identifier><language>eng</language><publisher>Chemical Society of Ethiopia</publisher><subject>Bovine liver ; ICP-OES ; Slurry nebulization</subject><ispartof>Bulletin of the Chemical Society of Ethiopia, 2008-12, Vol.22 (3), p.313-321</ispartof><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784</link.rule.ids></links><search><creatorcontrib>Ntebogeng S. Mokgalaka</creatorcontrib><creatorcontrib>Taddese Wondimu</creatorcontrib><creatorcontrib>Robert I. McCrindle</creatorcontrib><title>Slurry nebulization ICP-OES for the determination of Cu, Fe, Mg, Mn and Zn in bovine liver</title><title>Bulletin of the Chemical Society of Ethiopia</title><description>A method that involves analysis of bovine liver by slurry nebulization and ICP-OES has been developed. This method permits rapid and accurate determination of Cu, Fe, Mg, Mn and Zn in bovine liver. Aliquots of freeze-dried and powdered bovine liver sample were dispersed in 2.0 M HNO3 and sonicated to homogenize the resulting slurries. Bovine liver samples were also microwave digested or subjected to aqueous extraction for comparison of analytical results. Concentrations of Cu, Fe, Mg, Mn and Zn in aqueous slurries, the digests, and aqueous extracts were determined by the ICP-OES using external calibration curves. A student’s t-test showed that the results obtained using the slurry method were in good agreement at 95 % confidence level (CL) with those of microwave digestion or aqueous extraction techniques, except for Fe. To check the accuracy and precision of the slurry method, a bovine liver CRM was analyzed and good agreement was achieved with the certified values at 95 % CL. The results demonstrate inefficiency of aqueous extraction technique for complete removal of Fe in bovine liver sample.</description><subject>Bovine liver</subject><subject>ICP-OES</subject><subject>Slurry nebulization</subject><issn>1011-3924</issn><issn>1726-801X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2008</creationdate><recordtype>article</recordtype><sourceid>DOA</sourceid><recordid>eNotjNFKwzAYhYsoOKfvkAdYIUnTJL2UsulgY8IUZDflT_JnZnSJZN1gPr3DeXE4H-eDc1OMmOKy1JR93l6YMlZWDRf3xcPhsKOU00rVo2Kz7o85n0lEc-zDDwwhRTJv38rVdE18ymT4QuJwwLwP8WqTJ-1xQmY4IcvtJZFAdGQTSYjEpFOISPpwwvxY3HnoD_j03-PiYzZ9b1_Lxepl3j4vSsc5G0pgktYVSoloXW24kDUD5Tl4g4Ki56Lx3jKUjtZKNEZL8NpXSjCHFqSsxsX8-usS7LrvHPaQz12C0P0NKW87yEOwPXYaZKM5M9IqEIwqTY2SWisjrLTAXfULQQRa2A</recordid><startdate>20081201</startdate><enddate>20081201</enddate><creator>Ntebogeng S. Mokgalaka</creator><creator>Taddese Wondimu</creator><creator>Robert I. McCrindle</creator><general>Chemical Society of Ethiopia</general><scope>DOA</scope></search><sort><creationdate>20081201</creationdate><title>Slurry nebulization ICP-OES for the determination of Cu, Fe, Mg, Mn and Zn in bovine liver</title><author>Ntebogeng S. Mokgalaka ; Taddese Wondimu ; Robert I. McCrindle</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-d221t-a16053e66eecd5b24651a7f2afbe40ef249ffc1e6d05749b86af8f3741deca663</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2008</creationdate><topic>Bovine liver</topic><topic>ICP-OES</topic><topic>Slurry nebulization</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Ntebogeng S. Mokgalaka</creatorcontrib><creatorcontrib>Taddese Wondimu</creatorcontrib><creatorcontrib>Robert I. McCrindle</creatorcontrib><collection>DOAJ Directory of Open Access Journals</collection><jtitle>Bulletin of the Chemical Society of Ethiopia</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Ntebogeng S. Mokgalaka</au><au>Taddese Wondimu</au><au>Robert I. McCrindle</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Slurry nebulization ICP-OES for the determination of Cu, Fe, Mg, Mn and Zn in bovine liver</atitle><jtitle>Bulletin of the Chemical Society of Ethiopia</jtitle><date>2008-12-01</date><risdate>2008</risdate><volume>22</volume><issue>3</issue><spage>313</spage><epage>321</epage><pages>313-321</pages><issn>1011-3924</issn><eissn>1726-801X</eissn><abstract>A method that involves analysis of bovine liver by slurry nebulization and ICP-OES has been developed. This method permits rapid and accurate determination of Cu, Fe, Mg, Mn and Zn in bovine liver. Aliquots of freeze-dried and powdered bovine liver sample were dispersed in 2.0 M HNO3 and sonicated to homogenize the resulting slurries. Bovine liver samples were also microwave digested or subjected to aqueous extraction for comparison of analytical results. Concentrations of Cu, Fe, Mg, Mn and Zn in aqueous slurries, the digests, and aqueous extracts were determined by the ICP-OES using external calibration curves. A student’s t-test showed that the results obtained using the slurry method were in good agreement at 95 % confidence level (CL) with those of microwave digestion or aqueous extraction techniques, except for Fe. To check the accuracy and precision of the slurry method, a bovine liver CRM was analyzed and good agreement was achieved with the certified values at 95 % CL. The results demonstrate inefficiency of aqueous extraction technique for complete removal of Fe in bovine liver sample.</abstract><pub>Chemical Society of Ethiopia</pub><tpages>9</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1011-3924
ispartof Bulletin of the Chemical Society of Ethiopia, 2008-12, Vol.22 (3), p.313-321
issn 1011-3924
1726-801X
language eng
recordid cdi_doaj_primary_oai_doaj_org_article_8a69821b6c7a410780b76887b4c6ca2d
source Free Full-Text Journals in Chemistry
subjects Bovine liver
ICP-OES
Slurry nebulization
title Slurry nebulization ICP-OES for the determination of Cu, Fe, Mg, Mn and Zn in bovine liver
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-29T02%3A21%3A24IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-doaj&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Slurry%20nebulization%20ICP-OES%20for%20the%20determination%20of%20Cu,%20Fe,%20Mg,%20Mn%20and%20Zn%20in%20bovine%20liver&rft.jtitle=Bulletin%20of%20the%20Chemical%20Society%20of%20Ethiopia&rft.au=Ntebogeng%20S.%20Mokgalaka&rft.date=2008-12-01&rft.volume=22&rft.issue=3&rft.spage=313&rft.epage=321&rft.pages=313-321&rft.issn=1011-3924&rft.eissn=1726-801X&rft_id=info:doi/&rft_dat=%3Cdoaj%3Eoai_doaj_org_article_8a69821b6c7a410780b76887b4c6ca2d%3C/doaj%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-d221t-a16053e66eecd5b24651a7f2afbe40ef249ffc1e6d05749b86af8f3741deca663%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true