Sensitivity of Piezoelectric-Based Smart Interfaces to Structural Damage in Bolted Connections
This study presents a set of experimental and numerical investigations to study the sensitivity of the piezoelectric-based smart interface device to structural damage in a bolted connection. The study aims to identify the proper geometric sizes of smart interfaces for damage detection tasks. First,...
Saved in:
Published in: | Sensors (Basel, Switzerland) Switzerland), 2019-08, Vol.19 (17), p.3670 |
---|---|
Main Authors: | , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c469t-883e8d07aa064990952a0edea60923678289ab7827efdbd72d04d4b0d81580bd3 |
---|---|
cites | cdi_FETCH-LOGICAL-c469t-883e8d07aa064990952a0edea60923678289ab7827efdbd72d04d4b0d81580bd3 |
container_end_page | |
container_issue | 17 |
container_start_page | 3670 |
container_title | Sensors (Basel, Switzerland) |
container_volume | 19 |
creator | Huynh, Thanh-Canh Ho, Duc-Duy Dang, Ngoc-Loi Kim, And Jeong-Tae |
description | This study presents a set of experimental and numerical investigations to study the sensitivity of the piezoelectric-based smart interface device to structural damage in a bolted connection. The study aims to identify the proper geometric sizes of smart interfaces for damage detection tasks. First, the fundamentals of the damage monitoring technique via lead zirconate titanate(PZT) interface is briefly described for a bolted connection. Second, a lab-scaled girder connection is selected as the test structure for the experimental investigation. PZT interface prototypes with varying geometric sizes are designed for the test connection. Under the bolt-loosening inflicted in the connection, the impedance responses of the PZT interfaces are analyzed to understand the effect of geometric parameters on the damage sensitivity of the impedance responses. Subsequently, the bolt-loosening detection capabilities of the PZT interfaces are comparatively evaluated for identifying the proper geometric sizes of the devices. Finally, a finite element model of the PZT interface-bolted connection system is established for the numerical investigation. The damage sensitivity of the numerical impedance responses is compared with the experimental results for the verification. |
doi_str_mv | 10.3390/s19173670 |
format | article |
fullrecord | <record><control><sourceid>proquest_doaj_</sourceid><recordid>TN_cdi_doaj_primary_oai_doaj_org_article_8f48ff17ee3242f29c078a815a5c9e6a</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><doaj_id>oai_doaj_org_article_8f48ff17ee3242f29c078a815a5c9e6a</doaj_id><sourcerecordid>2301788712</sourcerecordid><originalsourceid>FETCH-LOGICAL-c469t-883e8d07aa064990952a0edea60923678289ab7827efdbd72d04d4b0d81580bd3</originalsourceid><addsrcrecordid>eNpdkk2LFDEQhoMo7rp68A9Igxc9tOarO8lFcMevgQWF0ashnVTGDD3JmqQX1l9vdNZh11OF5OGh3lQh9JTgV4wp_LoQRQQbBb6HTgmnvJeU4vu3zifoUSk7jCljTD5EJ4zwAUvCTtH3DcQSargK9bpLvvsS4FeCGWzNwfbnpoDrNnuTa7eOFbI3FkpXU7epebF1yWbu3pm92UIXYnee5tr4VYqxCUKK5TF64M1c4MlNPUPfPrz_uvrUX3z-uF69vegtH1XtpWQgHRbG4JErhdVADQYHZsSKtmCSSmWmVgR4NzlBHeaOT9hJMkg8OXaG1gevS2anL3NoLV_rZIL-e5HyVrcMwc6gpefSeyIAGOXUU2WxkKaJzGAVjKa53hxcl8u0B2ch1hbzjvTuSww_9DZd6VFwxQfVBC9uBDn9XKBUvQ_FwjybCGkpmlJJSBsB4Q19_h-6S0uO7as0ZZgIKQWhjXp5oGxOpWTwx2YI1n82QB83oLHPbnd_JP-NnP0G_1SrPw</addsrcrecordid><sourcetype>Open Website</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2301788712</pqid></control><display><type>article</type><title>Sensitivity of Piezoelectric-Based Smart Interfaces to Structural Damage in Bolted Connections</title><source>Open Access: PubMed Central</source><source>Publicly Available Content Database</source><creator>Huynh, Thanh-Canh ; Ho, Duc-Duy ; Dang, Ngoc-Loi ; Kim, And Jeong-Tae</creator><creatorcontrib>Huynh, Thanh-Canh ; Ho, Duc-Duy ; Dang, Ngoc-Loi ; Kim, And Jeong-Tae</creatorcontrib><description>This study presents a set of experimental and numerical investigations to study the sensitivity of the piezoelectric-based smart interface device to structural damage in a bolted connection. The study aims to identify the proper geometric sizes of smart interfaces for damage detection tasks. First, the fundamentals of the damage monitoring technique via lead zirconate titanate(PZT) interface is briefly described for a bolted connection. Second, a lab-scaled girder connection is selected as the test structure for the experimental investigation. PZT interface prototypes with varying geometric sizes are designed for the test connection. Under the bolt-loosening inflicted in the connection, the impedance responses of the PZT interfaces are analyzed to understand the effect of geometric parameters on the damage sensitivity of the impedance responses. Subsequently, the bolt-loosening detection capabilities of the PZT interfaces are comparatively evaluated for identifying the proper geometric sizes of the devices. Finally, a finite element model of the PZT interface-bolted connection system is established for the numerical investigation. The damage sensitivity of the numerical impedance responses is compared with the experimental results for the verification.</description><identifier>ISSN: 1424-8220</identifier><identifier>EISSN: 1424-8220</identifier><identifier>DOI: 10.3390/s19173670</identifier><identifier>PMID: 31450813</identifier><language>eng</language><publisher>Switzerland: MDPI AG</publisher><subject>Adhesive bonding ; bolted connection ; Bolted joints ; Bolts ; Civil engineering ; Damage detection ; Design ; Feasibility studies ; geometric effect ; Impedance ; impedance method ; impedance responses ; Influence ; lead zirconate titanate (PZT) ; loosened bolt ; Loosening ; Parameter sensitivity ; piezoelectric interface ; piezoelectric sensors ; Sensitivity ; Sensors ; Temperature effects</subject><ispartof>Sensors (Basel, Switzerland), 2019-08, Vol.19 (17), p.3670</ispartof><rights>2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.</rights><rights>2019 by the authors. 2019</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c469t-883e8d07aa064990952a0edea60923678289ab7827efdbd72d04d4b0d81580bd3</citedby><cites>FETCH-LOGICAL-c469t-883e8d07aa064990952a0edea60923678289ab7827efdbd72d04d4b0d81580bd3</cites><orcidid>0000-0002-9231-2129 ; 0000-0002-9081-1338 ; 0000-0002-1330-7445</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.proquest.com/docview/2301788712/fulltextPDF?pq-origsite=primo$$EPDF$$P50$$Gproquest$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.proquest.com/docview/2301788712?pq-origsite=primo$$EHTML$$P50$$Gproquest$$Hfree_for_read</linktohtml><link.rule.ids>230,314,727,780,784,885,25753,27924,27925,37012,37013,44590,53791,53793,75126</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/31450813$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Huynh, Thanh-Canh</creatorcontrib><creatorcontrib>Ho, Duc-Duy</creatorcontrib><creatorcontrib>Dang, Ngoc-Loi</creatorcontrib><creatorcontrib>Kim, And Jeong-Tae</creatorcontrib><title>Sensitivity of Piezoelectric-Based Smart Interfaces to Structural Damage in Bolted Connections</title><title>Sensors (Basel, Switzerland)</title><addtitle>Sensors (Basel)</addtitle><description>This study presents a set of experimental and numerical investigations to study the sensitivity of the piezoelectric-based smart interface device to structural damage in a bolted connection. The study aims to identify the proper geometric sizes of smart interfaces for damage detection tasks. First, the fundamentals of the damage monitoring technique via lead zirconate titanate(PZT) interface is briefly described for a bolted connection. Second, a lab-scaled girder connection is selected as the test structure for the experimental investigation. PZT interface prototypes with varying geometric sizes are designed for the test connection. Under the bolt-loosening inflicted in the connection, the impedance responses of the PZT interfaces are analyzed to understand the effect of geometric parameters on the damage sensitivity of the impedance responses. Subsequently, the bolt-loosening detection capabilities of the PZT interfaces are comparatively evaluated for identifying the proper geometric sizes of the devices. Finally, a finite element model of the PZT interface-bolted connection system is established for the numerical investigation. The damage sensitivity of the numerical impedance responses is compared with the experimental results for the verification.</description><subject>Adhesive bonding</subject><subject>bolted connection</subject><subject>Bolted joints</subject><subject>Bolts</subject><subject>Civil engineering</subject><subject>Damage detection</subject><subject>Design</subject><subject>Feasibility studies</subject><subject>geometric effect</subject><subject>Impedance</subject><subject>impedance method</subject><subject>impedance responses</subject><subject>Influence</subject><subject>lead zirconate titanate (PZT)</subject><subject>loosened bolt</subject><subject>Loosening</subject><subject>Parameter sensitivity</subject><subject>piezoelectric interface</subject><subject>piezoelectric sensors</subject><subject>Sensitivity</subject><subject>Sensors</subject><subject>Temperature effects</subject><issn>1424-8220</issn><issn>1424-8220</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2019</creationdate><recordtype>article</recordtype><sourceid>PIMPY</sourceid><sourceid>DOA</sourceid><recordid>eNpdkk2LFDEQhoMo7rp68A9Igxc9tOarO8lFcMevgQWF0ashnVTGDD3JmqQX1l9vdNZh11OF5OGh3lQh9JTgV4wp_LoQRQQbBb6HTgmnvJeU4vu3zifoUSk7jCljTD5EJ4zwAUvCTtH3DcQSargK9bpLvvsS4FeCGWzNwfbnpoDrNnuTa7eOFbI3FkpXU7epebF1yWbu3pm92UIXYnee5tr4VYqxCUKK5TF64M1c4MlNPUPfPrz_uvrUX3z-uF69vegtH1XtpWQgHRbG4JErhdVADQYHZsSKtmCSSmWmVgR4NzlBHeaOT9hJMkg8OXaG1gevS2anL3NoLV_rZIL-e5HyVrcMwc6gpefSeyIAGOXUU2WxkKaJzGAVjKa53hxcl8u0B2ch1hbzjvTuSww_9DZd6VFwxQfVBC9uBDn9XKBUvQ_FwjybCGkpmlJJSBsB4Q19_h-6S0uO7as0ZZgIKQWhjXp5oGxOpWTwx2YI1n82QB83oLHPbnd_JP-NnP0G_1SrPw</recordid><startdate>20190823</startdate><enddate>20190823</enddate><creator>Huynh, Thanh-Canh</creator><creator>Ho, Duc-Duy</creator><creator>Dang, Ngoc-Loi</creator><creator>Kim, And Jeong-Tae</creator><general>MDPI AG</general><general>MDPI</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>3V.</scope><scope>7X7</scope><scope>7XB</scope><scope>88E</scope><scope>8FI</scope><scope>8FJ</scope><scope>8FK</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>FYUFA</scope><scope>GHDGH</scope><scope>K9.</scope><scope>M0S</scope><scope>M1P</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>7X8</scope><scope>5PM</scope><scope>DOA</scope><orcidid>https://orcid.org/0000-0002-9231-2129</orcidid><orcidid>https://orcid.org/0000-0002-9081-1338</orcidid><orcidid>https://orcid.org/0000-0002-1330-7445</orcidid></search><sort><creationdate>20190823</creationdate><title>Sensitivity of Piezoelectric-Based Smart Interfaces to Structural Damage in Bolted Connections</title><author>Huynh, Thanh-Canh ; Ho, Duc-Duy ; Dang, Ngoc-Loi ; Kim, And Jeong-Tae</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c469t-883e8d07aa064990952a0edea60923678289ab7827efdbd72d04d4b0d81580bd3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2019</creationdate><topic>Adhesive bonding</topic><topic>bolted connection</topic><topic>Bolted joints</topic><topic>Bolts</topic><topic>Civil engineering</topic><topic>Damage detection</topic><topic>Design</topic><topic>Feasibility studies</topic><topic>geometric effect</topic><topic>Impedance</topic><topic>impedance method</topic><topic>impedance responses</topic><topic>Influence</topic><topic>lead zirconate titanate (PZT)</topic><topic>loosened bolt</topic><topic>Loosening</topic><topic>Parameter sensitivity</topic><topic>piezoelectric interface</topic><topic>piezoelectric sensors</topic><topic>Sensitivity</topic><topic>Sensors</topic><topic>Temperature effects</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Huynh, Thanh-Canh</creatorcontrib><creatorcontrib>Ho, Duc-Duy</creatorcontrib><creatorcontrib>Dang, Ngoc-Loi</creatorcontrib><creatorcontrib>Kim, And Jeong-Tae</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>ProQuest Central (Corporate)</collection><collection>Health & Medical Complete (ProQuest Database)</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>Medical Database (Alumni Edition)</collection><collection>Hospital Premium Collection</collection><collection>Hospital Premium Collection (Alumni Edition)</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>ProQuest Central (Alumni)</collection><collection>ProQuest Central</collection><collection>ProQuest Central Essentials</collection><collection>AUTh Library subscriptions: ProQuest Central</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central</collection><collection>Health Research Premium Collection</collection><collection>Health Research Premium Collection (Alumni)</collection><collection>ProQuest Health & Medical Complete (Alumni)</collection><collection>Health & Medical Collection (Alumni Edition)</collection><collection>Medical Database</collection><collection>Publicly Available Content Database</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><collection>Directory of Open Access Journals</collection><jtitle>Sensors (Basel, Switzerland)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Huynh, Thanh-Canh</au><au>Ho, Duc-Duy</au><au>Dang, Ngoc-Loi</au><au>Kim, And Jeong-Tae</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Sensitivity of Piezoelectric-Based Smart Interfaces to Structural Damage in Bolted Connections</atitle><jtitle>Sensors (Basel, Switzerland)</jtitle><addtitle>Sensors (Basel)</addtitle><date>2019-08-23</date><risdate>2019</risdate><volume>19</volume><issue>17</issue><spage>3670</spage><pages>3670-</pages><issn>1424-8220</issn><eissn>1424-8220</eissn><abstract>This study presents a set of experimental and numerical investigations to study the sensitivity of the piezoelectric-based smart interface device to structural damage in a bolted connection. The study aims to identify the proper geometric sizes of smart interfaces for damage detection tasks. First, the fundamentals of the damage monitoring technique via lead zirconate titanate(PZT) interface is briefly described for a bolted connection. Second, a lab-scaled girder connection is selected as the test structure for the experimental investigation. PZT interface prototypes with varying geometric sizes are designed for the test connection. Under the bolt-loosening inflicted in the connection, the impedance responses of the PZT interfaces are analyzed to understand the effect of geometric parameters on the damage sensitivity of the impedance responses. Subsequently, the bolt-loosening detection capabilities of the PZT interfaces are comparatively evaluated for identifying the proper geometric sizes of the devices. Finally, a finite element model of the PZT interface-bolted connection system is established for the numerical investigation. The damage sensitivity of the numerical impedance responses is compared with the experimental results for the verification.</abstract><cop>Switzerland</cop><pub>MDPI AG</pub><pmid>31450813</pmid><doi>10.3390/s19173670</doi><orcidid>https://orcid.org/0000-0002-9231-2129</orcidid><orcidid>https://orcid.org/0000-0002-9081-1338</orcidid><orcidid>https://orcid.org/0000-0002-1330-7445</orcidid><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1424-8220 |
ispartof | Sensors (Basel, Switzerland), 2019-08, Vol.19 (17), p.3670 |
issn | 1424-8220 1424-8220 |
language | eng |
recordid | cdi_doaj_primary_oai_doaj_org_article_8f48ff17ee3242f29c078a815a5c9e6a |
source | Open Access: PubMed Central; Publicly Available Content Database |
subjects | Adhesive bonding bolted connection Bolted joints Bolts Civil engineering Damage detection Design Feasibility studies geometric effect Impedance impedance method impedance responses Influence lead zirconate titanate (PZT) loosened bolt Loosening Parameter sensitivity piezoelectric interface piezoelectric sensors Sensitivity Sensors Temperature effects |
title | Sensitivity of Piezoelectric-Based Smart Interfaces to Structural Damage in Bolted Connections |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-27T10%3A33%3A56IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_doaj_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Sensitivity%20of%20Piezoelectric-Based%20Smart%20Interfaces%20to%20Structural%20Damage%20in%20Bolted%20Connections&rft.jtitle=Sensors%20(Basel,%20Switzerland)&rft.au=Huynh,%20Thanh-Canh&rft.date=2019-08-23&rft.volume=19&rft.issue=17&rft.spage=3670&rft.pages=3670-&rft.issn=1424-8220&rft.eissn=1424-8220&rft_id=info:doi/10.3390/s19173670&rft_dat=%3Cproquest_doaj_%3E2301788712%3C/proquest_doaj_%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c469t-883e8d07aa064990952a0edea60923678289ab7827efdbd72d04d4b0d81580bd3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2301788712&rft_id=info:pmid/31450813&rfr_iscdi=true |