The Prediction of the Leakage Airflow Rate Using the Supply and Return Airflow Rate in a Variable Air Volume System

Pressure differences in the envelope of a building result in leakage airflow (i.e., the unintended flow of air). This can lead to increased building heating and cooling energy, decreased thermal comfort for occupants, and the spread of moisture. To address this problem, it is necessary to know the l...

Full description

Saved in:
Bibliographic Details
Published in:Applied sciences 2024-11, Vol.14 (22), p.10363
Main Authors: Kim, Kyung-Won, Kim, Hyo-Jun, Lee, Jin-Hyun, Cho, Young-Hum
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Pressure differences in the envelope of a building result in leakage airflow (i.e., the unintended flow of air). This can lead to increased building heating and cooling energy, decreased thermal comfort for occupants, and the spread of moisture. To address this problem, it is necessary to know the leakage airflow in a building. Generally, the leakage airflow in a building is calculated by determining the leakage function through fan pressurization methods, such as the blower door test, and substituting the pressure difference measured by the pressure sensor. However, it is difficult to install continuous pressure sensors in an operating building. Therefore, this study proposes a method to utilize the supply and return airflow of an air conditioning system to predict the variation in the leakage airflow with changing indoor and outdoor airflow, and the efficacy of this approach was verified through experiments. The experiment measured the indoor and outdoor pressure difference of the building with a change in the speed of the supply and return fans and the opening rate of the variable air volume (VAV) damper. As a result of the experiment, the indoor–outdoor pressure difference is proportional to the difference between the indoor supply airflow and the ventilation airflow. In addition, the relationship between the pressure difference and the leakage airflow was derived through the pressurization/decompression method using an air handler, and the leakage airflow from the pressure difference generated by the operation of the air conditioning system was calculated. Lastly, the relationship between the supply and return airflow difference and the leakage airflow was derived based on the experimental results, and the leakage airflow was predicted based on the relationship.
ISSN:2076-3417
2076-3417
DOI:10.3390/app142210363