Loading…
Kinematic model and its parameter identification for cannula flexible needle insertion into soft tissue
In minimally invasive surgery, flexible needle insertion is a popular application which has been extensively researched. However, needle steering is challenging for a bevel tip cannula flexible needle due to the nonholonomic constraints and the rebounds of the needle shaft when the needle tip is reo...
Saved in:
Published in: | Advances in mechanical engineering 2019-06, Vol.11 (6), p.168781401985218 |
---|---|
Main Authors: | , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c417t-c02880e9b038d9902d4404469bf7e94f46e7de74254f4d6833635a451f5486ca3 |
---|---|
cites | cdi_FETCH-LOGICAL-c417t-c02880e9b038d9902d4404469bf7e94f46e7de74254f4d6833635a451f5486ca3 |
container_end_page | |
container_issue | 6 |
container_start_page | 168781401985218 |
container_title | Advances in mechanical engineering |
container_volume | 11 |
creator | Zhao, Yan-Jiang Liu, Ze-Hua Zhang, Yong-De Liu, Zhi-Qing |
description | In minimally invasive surgery, flexible needle insertion is a popular application which has been extensively researched. However, needle steering is challenging for a bevel tip cannula flexible needle due to the nonholonomic constraints and the rebounds of the needle shaft when the needle tip is reoriented. We proposed a novel kinematic model for the bevel tip cannula flexible needle based on bicycle and unicycle models, taking consideration of the deflection of the bevel tip and the rebounds of the needle shaft. Aiming at different types of paths, forward kinematics of the model was analyzed and calculated. Each parameter of the kinematic models was identified based on the experimental data using the least square method. Furthermore, the changing rules of parameters were explored under different angles of the bevel tip. The experimental results show that the errors of the proposed kinematic models are within 2 mm, which is greatly reduced compared to the traditional bicycle or unicycle model, and fulfill a general clinical surgery. |
doi_str_mv | 10.1177/1687814019852185 |
format | article |
fullrecord | <record><control><sourceid>proquest_doaj_</sourceid><recordid>TN_cdi_doaj_primary_oai_doaj_org_article_9568a3d90da846db990492fc593c3ccf</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sage_id>10.1177_1687814019852185</sage_id><doaj_id>oai_doaj_org_article_9568a3d90da846db990492fc593c3ccf</doaj_id><sourcerecordid>2251005154</sourcerecordid><originalsourceid>FETCH-LOGICAL-c417t-c02880e9b038d9902d4404469bf7e94f46e7de74254f4d6833635a451f5486ca3</originalsourceid><addsrcrecordid>eNp1kUtLBDEQhAdRUHTvHgOeR5PJY5KjiC8UvOg5ZJLOEplN1iQL-u_NuqIgeOqi-Lq6oLvulOBzQsbxggg5SsIwUZIPRPK97mhr9Vtv_0fT4bBblBImzLHAWCh11C0fQoSVqcGiVXIwIxMdCrWgtclmBRUyCg5iDT7YRqWIfMrImhg3s0F-hvcwzYAigGsjxAL5iwqxJlSSr6iGUjZw0h14MxdYfM_j7uXm-vnqrn98ur2_unzsLSNj7S0epMSgJkylUwoPjjHMmFCTH0ExzwSMDkY28KadkJQKyg3jxHMmhTX0uLvf5bpkXvU6h5XJHzqZoL-MlJfatIZ2Bq24kIY6hZ2RTLipnWNq8JYraqm1vmWd7bLWOb1toFT9mjY5tvp6GDjBmBPOGoV3lM2plAz-5yrBevsd_fc7baXfrRSzhN_Qf_lPommOZg</addsrcrecordid><sourcetype>Open Website</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2251005154</pqid></control><display><type>article</type><title>Kinematic model and its parameter identification for cannula flexible needle insertion into soft tissue</title><source>SAGE Open Access</source><source>Publicly Available Content Database</source><creator>Zhao, Yan-Jiang ; Liu, Ze-Hua ; Zhang, Yong-De ; Liu, Zhi-Qing</creator><creatorcontrib>Zhao, Yan-Jiang ; Liu, Ze-Hua ; Zhang, Yong-De ; Liu, Zhi-Qing</creatorcontrib><description>In minimally invasive surgery, flexible needle insertion is a popular application which has been extensively researched. However, needle steering is challenging for a bevel tip cannula flexible needle due to the nonholonomic constraints and the rebounds of the needle shaft when the needle tip is reoriented. We proposed a novel kinematic model for the bevel tip cannula flexible needle based on bicycle and unicycle models, taking consideration of the deflection of the bevel tip and the rebounds of the needle shaft. Aiming at different types of paths, forward kinematics of the model was analyzed and calculated. Each parameter of the kinematic models was identified based on the experimental data using the least square method. Furthermore, the changing rules of parameters were explored under different angles of the bevel tip. The experimental results show that the errors of the proposed kinematic models are within 2 mm, which is greatly reduced compared to the traditional bicycle or unicycle model, and fulfill a general clinical surgery.</description><identifier>ISSN: 1687-8132</identifier><identifier>ISSN: 1687-8140</identifier><identifier>EISSN: 1687-8140</identifier><identifier>DOI: 10.1177/1687814019852185</identifier><language>eng</language><publisher>London, England: SAGE Publications</publisher><subject>Bicycles ; Cannulae ; Hypodermic needles ; Insertion ; Kinematics ; Mathematical models ; Medical materials ; Parameter identification ; Soft tissues ; Steering ; Surgery</subject><ispartof>Advances in mechanical engineering, 2019-06, Vol.11 (6), p.168781401985218</ispartof><rights>The Author(s) 2019</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c417t-c02880e9b038d9902d4404469bf7e94f46e7de74254f4d6833635a451f5486ca3</citedby><cites>FETCH-LOGICAL-c417t-c02880e9b038d9902d4404469bf7e94f46e7de74254f4d6833635a451f5486ca3</cites><orcidid>0000-0001-6215-9293</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://journals.sagepub.com/doi/pdf/10.1177/1687814019852185$$EPDF$$P50$$Gsage$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://journals.sagepub.com/doi/10.1177/1687814019852185$$EHTML$$P50$$Gsage$$Hfree_for_read</linktohtml><link.rule.ids>314,780,784,21966,27853,27924,27925,37012,44945,45333</link.rule.ids></links><search><creatorcontrib>Zhao, Yan-Jiang</creatorcontrib><creatorcontrib>Liu, Ze-Hua</creatorcontrib><creatorcontrib>Zhang, Yong-De</creatorcontrib><creatorcontrib>Liu, Zhi-Qing</creatorcontrib><title>Kinematic model and its parameter identification for cannula flexible needle insertion into soft tissue</title><title>Advances in mechanical engineering</title><description>In minimally invasive surgery, flexible needle insertion is a popular application which has been extensively researched. However, needle steering is challenging for a bevel tip cannula flexible needle due to the nonholonomic constraints and the rebounds of the needle shaft when the needle tip is reoriented. We proposed a novel kinematic model for the bevel tip cannula flexible needle based on bicycle and unicycle models, taking consideration of the deflection of the bevel tip and the rebounds of the needle shaft. Aiming at different types of paths, forward kinematics of the model was analyzed and calculated. Each parameter of the kinematic models was identified based on the experimental data using the least square method. Furthermore, the changing rules of parameters were explored under different angles of the bevel tip. The experimental results show that the errors of the proposed kinematic models are within 2 mm, which is greatly reduced compared to the traditional bicycle or unicycle model, and fulfill a general clinical surgery.</description><subject>Bicycles</subject><subject>Cannulae</subject><subject>Hypodermic needles</subject><subject>Insertion</subject><subject>Kinematics</subject><subject>Mathematical models</subject><subject>Medical materials</subject><subject>Parameter identification</subject><subject>Soft tissues</subject><subject>Steering</subject><subject>Surgery</subject><issn>1687-8132</issn><issn>1687-8140</issn><issn>1687-8140</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2019</creationdate><recordtype>article</recordtype><sourceid>AFRWT</sourceid><sourceid>DOA</sourceid><recordid>eNp1kUtLBDEQhAdRUHTvHgOeR5PJY5KjiC8UvOg5ZJLOEplN1iQL-u_NuqIgeOqi-Lq6oLvulOBzQsbxggg5SsIwUZIPRPK97mhr9Vtv_0fT4bBblBImzLHAWCh11C0fQoSVqcGiVXIwIxMdCrWgtclmBRUyCg5iDT7YRqWIfMrImhg3s0F-hvcwzYAigGsjxAL5iwqxJlSSr6iGUjZw0h14MxdYfM_j7uXm-vnqrn98ur2_unzsLSNj7S0epMSgJkylUwoPjjHMmFCTH0ExzwSMDkY28KadkJQKyg3jxHMmhTX0uLvf5bpkXvU6h5XJHzqZoL-MlJfatIZ2Bq24kIY6hZ2RTLipnWNq8JYraqm1vmWd7bLWOb1toFT9mjY5tvp6GDjBmBPOGoV3lM2plAz-5yrBevsd_fc7baXfrRSzhN_Qf_lPommOZg</recordid><startdate>201906</startdate><enddate>201906</enddate><creator>Zhao, Yan-Jiang</creator><creator>Liu, Ze-Hua</creator><creator>Zhang, Yong-De</creator><creator>Liu, Zhi-Qing</creator><general>SAGE Publications</general><general>Sage Publications Ltd</general><general>SAGE Publishing</general><scope>AFRWT</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7TB</scope><scope>8FD</scope><scope>FR3</scope><scope>H8D</scope><scope>L7M</scope><scope>DOA</scope><orcidid>https://orcid.org/0000-0001-6215-9293</orcidid></search><sort><creationdate>201906</creationdate><title>Kinematic model and its parameter identification for cannula flexible needle insertion into soft tissue</title><author>Zhao, Yan-Jiang ; Liu, Ze-Hua ; Zhang, Yong-De ; Liu, Zhi-Qing</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c417t-c02880e9b038d9902d4404469bf7e94f46e7de74254f4d6833635a451f5486ca3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2019</creationdate><topic>Bicycles</topic><topic>Cannulae</topic><topic>Hypodermic needles</topic><topic>Insertion</topic><topic>Kinematics</topic><topic>Mathematical models</topic><topic>Medical materials</topic><topic>Parameter identification</topic><topic>Soft tissues</topic><topic>Steering</topic><topic>Surgery</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Zhao, Yan-Jiang</creatorcontrib><creatorcontrib>Liu, Ze-Hua</creatorcontrib><creatorcontrib>Zhang, Yong-De</creatorcontrib><creatorcontrib>Liu, Zhi-Qing</creatorcontrib><collection>SAGE Open Access</collection><collection>CrossRef</collection><collection>Mechanical & Transportation Engineering Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Aerospace Database</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>DOAJ Directory of Open Access Journals</collection><jtitle>Advances in mechanical engineering</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Zhao, Yan-Jiang</au><au>Liu, Ze-Hua</au><au>Zhang, Yong-De</au><au>Liu, Zhi-Qing</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Kinematic model and its parameter identification for cannula flexible needle insertion into soft tissue</atitle><jtitle>Advances in mechanical engineering</jtitle><date>2019-06</date><risdate>2019</risdate><volume>11</volume><issue>6</issue><spage>168781401985218</spage><pages>168781401985218-</pages><issn>1687-8132</issn><issn>1687-8140</issn><eissn>1687-8140</eissn><abstract>In minimally invasive surgery, flexible needle insertion is a popular application which has been extensively researched. However, needle steering is challenging for a bevel tip cannula flexible needle due to the nonholonomic constraints and the rebounds of the needle shaft when the needle tip is reoriented. We proposed a novel kinematic model for the bevel tip cannula flexible needle based on bicycle and unicycle models, taking consideration of the deflection of the bevel tip and the rebounds of the needle shaft. Aiming at different types of paths, forward kinematics of the model was analyzed and calculated. Each parameter of the kinematic models was identified based on the experimental data using the least square method. Furthermore, the changing rules of parameters were explored under different angles of the bevel tip. The experimental results show that the errors of the proposed kinematic models are within 2 mm, which is greatly reduced compared to the traditional bicycle or unicycle model, and fulfill a general clinical surgery.</abstract><cop>London, England</cop><pub>SAGE Publications</pub><doi>10.1177/1687814019852185</doi><orcidid>https://orcid.org/0000-0001-6215-9293</orcidid><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1687-8132 |
ispartof | Advances in mechanical engineering, 2019-06, Vol.11 (6), p.168781401985218 |
issn | 1687-8132 1687-8140 1687-8140 |
language | eng |
recordid | cdi_doaj_primary_oai_doaj_org_article_9568a3d90da846db990492fc593c3ccf |
source | SAGE Open Access; Publicly Available Content Database |
subjects | Bicycles Cannulae Hypodermic needles Insertion Kinematics Mathematical models Medical materials Parameter identification Soft tissues Steering Surgery |
title | Kinematic model and its parameter identification for cannula flexible needle insertion into soft tissue |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-07T07%3A43%3A08IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_doaj_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Kinematic%20model%20and%20its%20parameter%20identification%20for%20cannula%20flexible%20needle%20insertion%20into%20soft%20tissue&rft.jtitle=Advances%20in%20mechanical%20engineering&rft.au=Zhao,%20Yan-Jiang&rft.date=2019-06&rft.volume=11&rft.issue=6&rft.spage=168781401985218&rft.pages=168781401985218-&rft.issn=1687-8132&rft.eissn=1687-8140&rft_id=info:doi/10.1177/1687814019852185&rft_dat=%3Cproquest_doaj_%3E2251005154%3C/proquest_doaj_%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c417t-c02880e9b038d9902d4404469bf7e94f46e7de74254f4d6833635a451f5486ca3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2251005154&rft_id=info:pmid/&rft_sage_id=10.1177_1687814019852185&rfr_iscdi=true |