Synthetic CT generation for MRI-guided adaptive radiotherapy in prostate cancer

Current MRI-guided adaptive radiotherapy (MRgART) workflows require fraction-specific electron and/or mass density maps, which are created by deformable image registration (DIR) between the simulation CT images and daily MR images. Manual density overrides may also be needed where DIR-produced resul...

Full description

Saved in:
Bibliographic Details
Published in:Frontiers in oncology 2022-09, Vol.12, p.969463-969463
Main Authors: Hsu, Shu-Hui, Han, Zhaohui, Leeman, Jonathan E., Hu, Yue-Houng, Mak, Raymond H., Sudhyadhom, Atchar
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c439t-556a5ffebda05b7cbc259358f8d67978cc4736b05702ee79ada99f887b933afe3
cites cdi_FETCH-LOGICAL-c439t-556a5ffebda05b7cbc259358f8d67978cc4736b05702ee79ada99f887b933afe3
container_end_page 969463
container_issue
container_start_page 969463
container_title Frontiers in oncology
container_volume 12
creator Hsu, Shu-Hui
Han, Zhaohui
Leeman, Jonathan E.
Hu, Yue-Houng
Mak, Raymond H.
Sudhyadhom, Atchar
description Current MRI-guided adaptive radiotherapy (MRgART) workflows require fraction-specific electron and/or mass density maps, which are created by deformable image registration (DIR) between the simulation CT images and daily MR images. Manual density overrides may also be needed where DIR-produced results are inaccurate. This approach slows the adaptive radiotherapy workflow and introduces additional dosimetric uncertainties, especially in the presence of the magnetic field. This study investigated a method based on a conditional generative adversarial network (cGAN) with a multi-planar method to generate synthetic CT images from low-field MR images to improve efficiency in MRgART workflows for prostate cancer. Fifty-seven male patients, who received MRI-guided radiation therapy to the pelvis using the ViewRay MRIdian Linac, were selected. Forty-five cases were randomly assigned to the training cohort with the remaining twelve cases assigned to the validation/testing cohort. All patient datasets had a semi-paired DIR-deformed CT-sim image and 0.35T MR image acquired using a true fast imaging with steady-state precession (TrueFISP) sequence. Synthetic CT images were compared with deformed CT images to evaluate image quality and dosimetric accuracy. To evaluate the dosimetric accuracy of this method, clinical plans were recalculated on synthetic CT images in the MRIdian treatment planning system. Dose volume histograms for planning target volumes (PTVs) and organs-at-risk (OARs) and dose distributions using gamma analyses were evaluated. The mean-absolute-errors (MAEs) in CT numbers were 30.1 ± 4.2 HU, 19.6 ± 2.3 HU and 158.5 ± 26.0 HU for the whole pelvis, soft tissue, and bone, respectively. The peak signal-to-noise ratio was 35.2 ± 1.7 and the structural index similarity measure was 0.9758 ± 0.0035. The dosimetric difference was on average less than 1% for all PTV and OAR metrics. Plans showed good agreement with gamma pass rates of 99% and 99.9% for 1%/1 mm and 2%/2 mm, respectively. Our study demonstrates the potential of using synthetic CT images created with a multi-planar cGAN method from 0.35T MRI TrueFISP images for the MRgART treatment of prostate radiotherapy. Future work will validate the method in a large cohort of patients and investigate the limitations of the method in the adaptive workflow.
doi_str_mv 10.3389/fonc.2022.969463
format article
fullrecord <record><control><sourceid>proquest_doaj_</sourceid><recordid>TN_cdi_doaj_primary_oai_doaj_org_article_98f317057c454e7e9c419e0e718d45d4</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><doaj_id>oai_doaj_org_article_98f317057c454e7e9c419e0e718d45d4</doaj_id><sourcerecordid>2723485169</sourcerecordid><originalsourceid>FETCH-LOGICAL-c439t-556a5ffebda05b7cbc259358f8d67978cc4736b05702ee79ada99f887b933afe3</originalsourceid><addsrcrecordid>eNpVkVFrHCEQgJfSQkOS9z762Je9uquu-lIoR5MeJATaBPImszpeDHu6db3A_ft6vVCaeXEYx28Yv6b51NEVY0p_8SnaVU_7fqUHzQf2rjnre8Zbzdnj-__yj83lsjzTGoOgHWVnzd2vQyxPWIIl63uyxYgZSkiR-JTJ7c9Nu90Hh46Ag7mEFyQZXEj1RYb5QEIkc05LgYLEQrSYL5oPHqYFL1_P8-bh6vv9-kd7c3e9WX-7aS1nurRCDCC8x9EBFaO0o-2FZkJ55QappbKWSzaMVEjaI0pdx2vtlZKjZgw8svNmc-K6BM9mzmEH-WASBPO3kPLWQK5bTWi08qyTFWW54ChRW95ppCg75bhwvLK-nljzftyhsxhLhukN9O1NDE9mm16MFkzLgVXA51dATr_3uBSzC4vFaYKIab-YXlYBSnSDrq301Grrvy0Z_b8xHTVHl-bo0hxdmpNL9gfxR5QO</addsrcrecordid><sourcetype>Open Website</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2723485169</pqid></control><display><type>article</type><title>Synthetic CT generation for MRI-guided adaptive radiotherapy in prostate cancer</title><source>Open Access: PubMed Central</source><creator>Hsu, Shu-Hui ; Han, Zhaohui ; Leeman, Jonathan E. ; Hu, Yue-Houng ; Mak, Raymond H. ; Sudhyadhom, Atchar</creator><creatorcontrib>Hsu, Shu-Hui ; Han, Zhaohui ; Leeman, Jonathan E. ; Hu, Yue-Houng ; Mak, Raymond H. ; Sudhyadhom, Atchar</creatorcontrib><description>Current MRI-guided adaptive radiotherapy (MRgART) workflows require fraction-specific electron and/or mass density maps, which are created by deformable image registration (DIR) between the simulation CT images and daily MR images. Manual density overrides may also be needed where DIR-produced results are inaccurate. This approach slows the adaptive radiotherapy workflow and introduces additional dosimetric uncertainties, especially in the presence of the magnetic field. This study investigated a method based on a conditional generative adversarial network (cGAN) with a multi-planar method to generate synthetic CT images from low-field MR images to improve efficiency in MRgART workflows for prostate cancer. Fifty-seven male patients, who received MRI-guided radiation therapy to the pelvis using the ViewRay MRIdian Linac, were selected. Forty-five cases were randomly assigned to the training cohort with the remaining twelve cases assigned to the validation/testing cohort. All patient datasets had a semi-paired DIR-deformed CT-sim image and 0.35T MR image acquired using a true fast imaging with steady-state precession (TrueFISP) sequence. Synthetic CT images were compared with deformed CT images to evaluate image quality and dosimetric accuracy. To evaluate the dosimetric accuracy of this method, clinical plans were recalculated on synthetic CT images in the MRIdian treatment planning system. Dose volume histograms for planning target volumes (PTVs) and organs-at-risk (OARs) and dose distributions using gamma analyses were evaluated. The mean-absolute-errors (MAEs) in CT numbers were 30.1 ± 4.2 HU, 19.6 ± 2.3 HU and 158.5 ± 26.0 HU for the whole pelvis, soft tissue, and bone, respectively. The peak signal-to-noise ratio was 35.2 ± 1.7 and the structural index similarity measure was 0.9758 ± 0.0035. The dosimetric difference was on average less than 1% for all PTV and OAR metrics. Plans showed good agreement with gamma pass rates of 99% and 99.9% for 1%/1 mm and 2%/2 mm, respectively. Our study demonstrates the potential of using synthetic CT images created with a multi-planar cGAN method from 0.35T MRI TrueFISP images for the MRgART treatment of prostate radiotherapy. Future work will validate the method in a large cohort of patients and investigate the limitations of the method in the adaptive workflow.</description><identifier>ISSN: 2234-943X</identifier><identifier>EISSN: 2234-943X</identifier><identifier>DOI: 10.3389/fonc.2022.969463</identifier><language>eng</language><publisher>Frontiers Media S.A</publisher><subject>adaptive radiotherapy ; deep learning ; MRI-guided therapy ; Oncology ; prostate radiotherapy ; synthetic CT</subject><ispartof>Frontiers in oncology, 2022-09, Vol.12, p.969463-969463</ispartof><rights>Copyright © 2022 Hsu, Han, Leeman, Hu, Mak and Sudhyadhom 2022 Hsu, Han, Leeman, Hu, Mak and Sudhyadhom</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c439t-556a5ffebda05b7cbc259358f8d67978cc4736b05702ee79ada99f887b933afe3</citedby><cites>FETCH-LOGICAL-c439t-556a5ffebda05b7cbc259358f8d67978cc4736b05702ee79ada99f887b933afe3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC9539763/pdf/$$EPDF$$P50$$Gpubmedcentral$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC9539763/$$EHTML$$P50$$Gpubmedcentral$$Hfree_for_read</linktohtml><link.rule.ids>230,314,727,780,784,885,27924,27925,53791,53793</link.rule.ids></links><search><creatorcontrib>Hsu, Shu-Hui</creatorcontrib><creatorcontrib>Han, Zhaohui</creatorcontrib><creatorcontrib>Leeman, Jonathan E.</creatorcontrib><creatorcontrib>Hu, Yue-Houng</creatorcontrib><creatorcontrib>Mak, Raymond H.</creatorcontrib><creatorcontrib>Sudhyadhom, Atchar</creatorcontrib><title>Synthetic CT generation for MRI-guided adaptive radiotherapy in prostate cancer</title><title>Frontiers in oncology</title><description>Current MRI-guided adaptive radiotherapy (MRgART) workflows require fraction-specific electron and/or mass density maps, which are created by deformable image registration (DIR) between the simulation CT images and daily MR images. Manual density overrides may also be needed where DIR-produced results are inaccurate. This approach slows the adaptive radiotherapy workflow and introduces additional dosimetric uncertainties, especially in the presence of the magnetic field. This study investigated a method based on a conditional generative adversarial network (cGAN) with a multi-planar method to generate synthetic CT images from low-field MR images to improve efficiency in MRgART workflows for prostate cancer. Fifty-seven male patients, who received MRI-guided radiation therapy to the pelvis using the ViewRay MRIdian Linac, were selected. Forty-five cases were randomly assigned to the training cohort with the remaining twelve cases assigned to the validation/testing cohort. All patient datasets had a semi-paired DIR-deformed CT-sim image and 0.35T MR image acquired using a true fast imaging with steady-state precession (TrueFISP) sequence. Synthetic CT images were compared with deformed CT images to evaluate image quality and dosimetric accuracy. To evaluate the dosimetric accuracy of this method, clinical plans were recalculated on synthetic CT images in the MRIdian treatment planning system. Dose volume histograms for planning target volumes (PTVs) and organs-at-risk (OARs) and dose distributions using gamma analyses were evaluated. The mean-absolute-errors (MAEs) in CT numbers were 30.1 ± 4.2 HU, 19.6 ± 2.3 HU and 158.5 ± 26.0 HU for the whole pelvis, soft tissue, and bone, respectively. The peak signal-to-noise ratio was 35.2 ± 1.7 and the structural index similarity measure was 0.9758 ± 0.0035. The dosimetric difference was on average less than 1% for all PTV and OAR metrics. Plans showed good agreement with gamma pass rates of 99% and 99.9% for 1%/1 mm and 2%/2 mm, respectively. Our study demonstrates the potential of using synthetic CT images created with a multi-planar cGAN method from 0.35T MRI TrueFISP images for the MRgART treatment of prostate radiotherapy. Future work will validate the method in a large cohort of patients and investigate the limitations of the method in the adaptive workflow.</description><subject>adaptive radiotherapy</subject><subject>deep learning</subject><subject>MRI-guided therapy</subject><subject>Oncology</subject><subject>prostate radiotherapy</subject><subject>synthetic CT</subject><issn>2234-943X</issn><issn>2234-943X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2022</creationdate><recordtype>article</recordtype><sourceid>DOA</sourceid><recordid>eNpVkVFrHCEQgJfSQkOS9z762Je9uquu-lIoR5MeJATaBPImszpeDHu6db3A_ft6vVCaeXEYx28Yv6b51NEVY0p_8SnaVU_7fqUHzQf2rjnre8Zbzdnj-__yj83lsjzTGoOgHWVnzd2vQyxPWIIl63uyxYgZSkiR-JTJ7c9Nu90Hh46Ag7mEFyQZXEj1RYb5QEIkc05LgYLEQrSYL5oPHqYFL1_P8-bh6vv9-kd7c3e9WX-7aS1nurRCDCC8x9EBFaO0o-2FZkJ55QappbKWSzaMVEjaI0pdx2vtlZKjZgw8svNmc-K6BM9mzmEH-WASBPO3kPLWQK5bTWi08qyTFWW54ChRW95ppCg75bhwvLK-nljzftyhsxhLhukN9O1NDE9mm16MFkzLgVXA51dATr_3uBSzC4vFaYKIab-YXlYBSnSDrq301Grrvy0Z_b8xHTVHl-bo0hxdmpNL9gfxR5QO</recordid><startdate>20220923</startdate><enddate>20220923</enddate><creator>Hsu, Shu-Hui</creator><creator>Han, Zhaohui</creator><creator>Leeman, Jonathan E.</creator><creator>Hu, Yue-Houng</creator><creator>Mak, Raymond H.</creator><creator>Sudhyadhom, Atchar</creator><general>Frontiers Media S.A</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>5PM</scope><scope>DOA</scope></search><sort><creationdate>20220923</creationdate><title>Synthetic CT generation for MRI-guided adaptive radiotherapy in prostate cancer</title><author>Hsu, Shu-Hui ; Han, Zhaohui ; Leeman, Jonathan E. ; Hu, Yue-Houng ; Mak, Raymond H. ; Sudhyadhom, Atchar</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c439t-556a5ffebda05b7cbc259358f8d67978cc4736b05702ee79ada99f887b933afe3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2022</creationdate><topic>adaptive radiotherapy</topic><topic>deep learning</topic><topic>MRI-guided therapy</topic><topic>Oncology</topic><topic>prostate radiotherapy</topic><topic>synthetic CT</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Hsu, Shu-Hui</creatorcontrib><creatorcontrib>Han, Zhaohui</creatorcontrib><creatorcontrib>Leeman, Jonathan E.</creatorcontrib><creatorcontrib>Hu, Yue-Houng</creatorcontrib><creatorcontrib>Mak, Raymond H.</creatorcontrib><creatorcontrib>Sudhyadhom, Atchar</creatorcontrib><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><collection>Directory of Open Access Journals</collection><jtitle>Frontiers in oncology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Hsu, Shu-Hui</au><au>Han, Zhaohui</au><au>Leeman, Jonathan E.</au><au>Hu, Yue-Houng</au><au>Mak, Raymond H.</au><au>Sudhyadhom, Atchar</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Synthetic CT generation for MRI-guided adaptive radiotherapy in prostate cancer</atitle><jtitle>Frontiers in oncology</jtitle><date>2022-09-23</date><risdate>2022</risdate><volume>12</volume><spage>969463</spage><epage>969463</epage><pages>969463-969463</pages><issn>2234-943X</issn><eissn>2234-943X</eissn><abstract>Current MRI-guided adaptive radiotherapy (MRgART) workflows require fraction-specific electron and/or mass density maps, which are created by deformable image registration (DIR) between the simulation CT images and daily MR images. Manual density overrides may also be needed where DIR-produced results are inaccurate. This approach slows the adaptive radiotherapy workflow and introduces additional dosimetric uncertainties, especially in the presence of the magnetic field. This study investigated a method based on a conditional generative adversarial network (cGAN) with a multi-planar method to generate synthetic CT images from low-field MR images to improve efficiency in MRgART workflows for prostate cancer. Fifty-seven male patients, who received MRI-guided radiation therapy to the pelvis using the ViewRay MRIdian Linac, were selected. Forty-five cases were randomly assigned to the training cohort with the remaining twelve cases assigned to the validation/testing cohort. All patient datasets had a semi-paired DIR-deformed CT-sim image and 0.35T MR image acquired using a true fast imaging with steady-state precession (TrueFISP) sequence. Synthetic CT images were compared with deformed CT images to evaluate image quality and dosimetric accuracy. To evaluate the dosimetric accuracy of this method, clinical plans were recalculated on synthetic CT images in the MRIdian treatment planning system. Dose volume histograms for planning target volumes (PTVs) and organs-at-risk (OARs) and dose distributions using gamma analyses were evaluated. The mean-absolute-errors (MAEs) in CT numbers were 30.1 ± 4.2 HU, 19.6 ± 2.3 HU and 158.5 ± 26.0 HU for the whole pelvis, soft tissue, and bone, respectively. The peak signal-to-noise ratio was 35.2 ± 1.7 and the structural index similarity measure was 0.9758 ± 0.0035. The dosimetric difference was on average less than 1% for all PTV and OAR metrics. Plans showed good agreement with gamma pass rates of 99% and 99.9% for 1%/1 mm and 2%/2 mm, respectively. Our study demonstrates the potential of using synthetic CT images created with a multi-planar cGAN method from 0.35T MRI TrueFISP images for the MRgART treatment of prostate radiotherapy. Future work will validate the method in a large cohort of patients and investigate the limitations of the method in the adaptive workflow.</abstract><pub>Frontiers Media S.A</pub><doi>10.3389/fonc.2022.969463</doi><tpages>1</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 2234-943X
ispartof Frontiers in oncology, 2022-09, Vol.12, p.969463-969463
issn 2234-943X
2234-943X
language eng
recordid cdi_doaj_primary_oai_doaj_org_article_98f317057c454e7e9c419e0e718d45d4
source Open Access: PubMed Central
subjects adaptive radiotherapy
deep learning
MRI-guided therapy
Oncology
prostate radiotherapy
synthetic CT
title Synthetic CT generation for MRI-guided adaptive radiotherapy in prostate cancer
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-30T21%3A41%3A27IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_doaj_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Synthetic%20CT%20generation%20for%20MRI-guided%20adaptive%20radiotherapy%20in%20prostate%20cancer&rft.jtitle=Frontiers%20in%20oncology&rft.au=Hsu,%20Shu-Hui&rft.date=2022-09-23&rft.volume=12&rft.spage=969463&rft.epage=969463&rft.pages=969463-969463&rft.issn=2234-943X&rft.eissn=2234-943X&rft_id=info:doi/10.3389/fonc.2022.969463&rft_dat=%3Cproquest_doaj_%3E2723485169%3C/proquest_doaj_%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c439t-556a5ffebda05b7cbc259358f8d67978cc4736b05702ee79ada99f887b933afe3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2723485169&rft_id=info:pmid/&rfr_iscdi=true