Delivery, Beam and Range Monitoring in Particle Therapy in a Highly Innovative Integrated Design
The design of a particle therapy system that integrates an innovative beam delivery concept based on a static toroidal gantry and an imaging configuration suitable for beam and online range monitoring is proposed and discussed. Such approach would provide a compact and cost-effective layout, with a...
Saved in:
Published in: | Frontiers in physics 2020-11, Vol.8 |
---|---|
Main Authors: | , , , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c387t-cbc1ee831b17e49d9f9479ffe2e08ed4b561765cf1ab08ef8dab4905c38144763 |
---|---|
cites | cdi_FETCH-LOGICAL-c387t-cbc1ee831b17e49d9f9479ffe2e08ed4b561765cf1ab08ef8dab4905c38144763 |
container_end_page | |
container_issue | |
container_start_page | |
container_title | Frontiers in physics |
container_volume | 8 |
creator | Bottura, L. Felcini, E. Ferrero, V. Fiorina, E. Monaco, V. Pennazio, F. de Rijk, G. Cerello, P. |
description | The design of a particle therapy system that integrates an innovative beam delivery concept based on a static toroidal gantry and an imaging configuration suitable for beam and online range monitoring is proposed and discussed. Such approach would provide a compact and cost-effective layout, with a highly flexible and fast beam delivery, single particle counting capability for fast measurement of beam fluence and position and a precise real time verification of the compliance between the treatment delivery and its prescription. The gantry configuration is discussed, presenting an analysis of the residual magnetic field in the bore and of the feasibility of irradiating a realistic target volume. Moreover, the expected performance of the PET-based range monitor is assessed through Monte Carlo simulations, showing a precision in the reconstruction of the activity distribution from a clinical treatment plan better than the state-of-the-art devices. The feasibility of the proposed design is then discussed through an assessment of the technological improvements required to actually start the construction and commissioning of a system prototype. |
doi_str_mv | 10.3389/fphy.2020.566679 |
format | article |
fullrecord | <record><control><sourceid>doaj_cross</sourceid><recordid>TN_cdi_doaj_primary_oai_doaj_org_article_9a9ac8ca168b447ea2987d889e94a1f0</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><doaj_id>oai_doaj_org_article_9a9ac8ca168b447ea2987d889e94a1f0</doaj_id><sourcerecordid>oai_doaj_org_article_9a9ac8ca168b447ea2987d889e94a1f0</sourcerecordid><originalsourceid>FETCH-LOGICAL-c387t-cbc1ee831b17e49d9f9479ffe2e08ed4b561765cf1ab08ef8dab4905c38144763</originalsourceid><addsrcrecordid>eNpNkFFLwzAUhYsoOObefcwPsDNJ0zZ51E3dYKLIBN_ibXrTZWzpSMug_97WDfHpHg6cD-4XRbeMTpNEqnt72HRTTjmdplmW5eoiGnGuslhw8XX5L19Hk6bZUkoZT5XkYhR9z3Hnjhi6O_KIsCfgS_IBvkLyWnvX1sH5ijhP3iG0zuyQrDcY4NANHZCFqza7jiy9r4_Q9pw-tlgFaLEkc2xc5W-iKwu7BifnO44-n5_Ws0W8entZzh5WsUlk3samMAxRJqxgOQpVKqtErqxFjlRiKYo0Y3mWGsug6AsrSyiEomm_ZkLkWTKOliduWcNWH4LbQ-h0DU7_FnWo9PkFrUCBkQZYJot-i8CVzEspFSoBzNKeRU8sE-qmCWj_eIzqQbgehOtBuD4JT34AWo51Eg</addsrcrecordid><sourcetype>Open Website</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Delivery, Beam and Range Monitoring in Particle Therapy in a Highly Innovative Integrated Design</title><source>ROAD: Directory of Open Access Scholarly Resources</source><creator>Bottura, L. ; Felcini, E. ; Ferrero, V. ; Fiorina, E. ; Monaco, V. ; Pennazio, F. ; de Rijk, G. ; Cerello, P.</creator><creatorcontrib>Bottura, L. ; Felcini, E. ; Ferrero, V. ; Fiorina, E. ; Monaco, V. ; Pennazio, F. ; de Rijk, G. ; Cerello, P.</creatorcontrib><description>The design of a particle therapy system that integrates an innovative beam delivery concept based on a static toroidal gantry and an imaging configuration suitable for beam and online range monitoring is proposed and discussed. Such approach would provide a compact and cost-effective layout, with a highly flexible and fast beam delivery, single particle counting capability for fast measurement of beam fluence and position and a precise real time verification of the compliance between the treatment delivery and its prescription. The gantry configuration is discussed, presenting an analysis of the residual magnetic field in the bore and of the feasibility of irradiating a realistic target volume. Moreover, the expected performance of the PET-based range monitor is assessed through Monte Carlo simulations, showing a precision in the reconstruction of the activity distribution from a clinical treatment plan better than the state-of-the-art devices. The feasibility of the proposed design is then discussed through an assessment of the technological improvements required to actually start the construction and commissioning of a system prototype.</description><identifier>ISSN: 2296-424X</identifier><identifier>EISSN: 2296-424X</identifier><identifier>DOI: 10.3389/fphy.2020.566679</identifier><language>eng</language><publisher>Frontiers Media S.A</publisher><subject>beam monitor ; gantry ; particle therapy ; PET ; range monitor ; treatment verification</subject><ispartof>Frontiers in physics, 2020-11, Vol.8</ispartof><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c387t-cbc1ee831b17e49d9f9479ffe2e08ed4b561765cf1ab08ef8dab4905c38144763</citedby><cites>FETCH-LOGICAL-c387t-cbc1ee831b17e49d9f9479ffe2e08ed4b561765cf1ab08ef8dab4905c38144763</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><creatorcontrib>Bottura, L.</creatorcontrib><creatorcontrib>Felcini, E.</creatorcontrib><creatorcontrib>Ferrero, V.</creatorcontrib><creatorcontrib>Fiorina, E.</creatorcontrib><creatorcontrib>Monaco, V.</creatorcontrib><creatorcontrib>Pennazio, F.</creatorcontrib><creatorcontrib>de Rijk, G.</creatorcontrib><creatorcontrib>Cerello, P.</creatorcontrib><title>Delivery, Beam and Range Monitoring in Particle Therapy in a Highly Innovative Integrated Design</title><title>Frontiers in physics</title><description>The design of a particle therapy system that integrates an innovative beam delivery concept based on a static toroidal gantry and an imaging configuration suitable for beam and online range monitoring is proposed and discussed. Such approach would provide a compact and cost-effective layout, with a highly flexible and fast beam delivery, single particle counting capability for fast measurement of beam fluence and position and a precise real time verification of the compliance between the treatment delivery and its prescription. The gantry configuration is discussed, presenting an analysis of the residual magnetic field in the bore and of the feasibility of irradiating a realistic target volume. Moreover, the expected performance of the PET-based range monitor is assessed through Monte Carlo simulations, showing a precision in the reconstruction of the activity distribution from a clinical treatment plan better than the state-of-the-art devices. The feasibility of the proposed design is then discussed through an assessment of the technological improvements required to actually start the construction and commissioning of a system prototype.</description><subject>beam monitor</subject><subject>gantry</subject><subject>particle therapy</subject><subject>PET</subject><subject>range monitor</subject><subject>treatment verification</subject><issn>2296-424X</issn><issn>2296-424X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2020</creationdate><recordtype>article</recordtype><sourceid>DOA</sourceid><recordid>eNpNkFFLwzAUhYsoOObefcwPsDNJ0zZ51E3dYKLIBN_ibXrTZWzpSMug_97WDfHpHg6cD-4XRbeMTpNEqnt72HRTTjmdplmW5eoiGnGuslhw8XX5L19Hk6bZUkoZT5XkYhR9z3Hnjhi6O_KIsCfgS_IBvkLyWnvX1sH5ijhP3iG0zuyQrDcY4NANHZCFqza7jiy9r4_Q9pw-tlgFaLEkc2xc5W-iKwu7BifnO44-n5_Ws0W8entZzh5WsUlk3samMAxRJqxgOQpVKqtErqxFjlRiKYo0Y3mWGsug6AsrSyiEomm_ZkLkWTKOliduWcNWH4LbQ-h0DU7_FnWo9PkFrUCBkQZYJot-i8CVzEspFSoBzNKeRU8sE-qmCWj_eIzqQbgehOtBuD4JT34AWo51Eg</recordid><startdate>20201130</startdate><enddate>20201130</enddate><creator>Bottura, L.</creator><creator>Felcini, E.</creator><creator>Ferrero, V.</creator><creator>Fiorina, E.</creator><creator>Monaco, V.</creator><creator>Pennazio, F.</creator><creator>de Rijk, G.</creator><creator>Cerello, P.</creator><general>Frontiers Media S.A</general><scope>AAYXX</scope><scope>CITATION</scope><scope>DOA</scope></search><sort><creationdate>20201130</creationdate><title>Delivery, Beam and Range Monitoring in Particle Therapy in a Highly Innovative Integrated Design</title><author>Bottura, L. ; Felcini, E. ; Ferrero, V. ; Fiorina, E. ; Monaco, V. ; Pennazio, F. ; de Rijk, G. ; Cerello, P.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c387t-cbc1ee831b17e49d9f9479ffe2e08ed4b561765cf1ab08ef8dab4905c38144763</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2020</creationdate><topic>beam monitor</topic><topic>gantry</topic><topic>particle therapy</topic><topic>PET</topic><topic>range monitor</topic><topic>treatment verification</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Bottura, L.</creatorcontrib><creatorcontrib>Felcini, E.</creatorcontrib><creatorcontrib>Ferrero, V.</creatorcontrib><creatorcontrib>Fiorina, E.</creatorcontrib><creatorcontrib>Monaco, V.</creatorcontrib><creatorcontrib>Pennazio, F.</creatorcontrib><creatorcontrib>de Rijk, G.</creatorcontrib><creatorcontrib>Cerello, P.</creatorcontrib><collection>CrossRef</collection><collection>Directory of Open Access Journals</collection><jtitle>Frontiers in physics</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Bottura, L.</au><au>Felcini, E.</au><au>Ferrero, V.</au><au>Fiorina, E.</au><au>Monaco, V.</au><au>Pennazio, F.</au><au>de Rijk, G.</au><au>Cerello, P.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Delivery, Beam and Range Monitoring in Particle Therapy in a Highly Innovative Integrated Design</atitle><jtitle>Frontiers in physics</jtitle><date>2020-11-30</date><risdate>2020</risdate><volume>8</volume><issn>2296-424X</issn><eissn>2296-424X</eissn><abstract>The design of a particle therapy system that integrates an innovative beam delivery concept based on a static toroidal gantry and an imaging configuration suitable for beam and online range monitoring is proposed and discussed. Such approach would provide a compact and cost-effective layout, with a highly flexible and fast beam delivery, single particle counting capability for fast measurement of beam fluence and position and a precise real time verification of the compliance between the treatment delivery and its prescription. The gantry configuration is discussed, presenting an analysis of the residual magnetic field in the bore and of the feasibility of irradiating a realistic target volume. Moreover, the expected performance of the PET-based range monitor is assessed through Monte Carlo simulations, showing a precision in the reconstruction of the activity distribution from a clinical treatment plan better than the state-of-the-art devices. The feasibility of the proposed design is then discussed through an assessment of the technological improvements required to actually start the construction and commissioning of a system prototype.</abstract><pub>Frontiers Media S.A</pub><doi>10.3389/fphy.2020.566679</doi><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 2296-424X |
ispartof | Frontiers in physics, 2020-11, Vol.8 |
issn | 2296-424X 2296-424X |
language | eng |
recordid | cdi_doaj_primary_oai_doaj_org_article_9a9ac8ca168b447ea2987d889e94a1f0 |
source | ROAD: Directory of Open Access Scholarly Resources |
subjects | beam monitor gantry particle therapy PET range monitor treatment verification |
title | Delivery, Beam and Range Monitoring in Particle Therapy in a Highly Innovative Integrated Design |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-20T18%3A19%3A12IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-doaj_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Delivery,%20Beam%20and%20Range%20Monitoring%20in%20Particle%20Therapy%20in%20a%20Highly%20Innovative%20Integrated%20Design&rft.jtitle=Frontiers%20in%20physics&rft.au=Bottura,%20L.&rft.date=2020-11-30&rft.volume=8&rft.issn=2296-424X&rft.eissn=2296-424X&rft_id=info:doi/10.3389/fphy.2020.566679&rft_dat=%3Cdoaj_cross%3Eoai_doaj_org_article_9a9ac8ca168b447ea2987d889e94a1f0%3C/doaj_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c387t-cbc1ee831b17e49d9f9479ffe2e08ed4b561765cf1ab08ef8dab4905c38144763%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true |