A New Chemiluminescence Immunoassay for Phospholipase A2 Receptor 1 Autoantibodies Allows Early Identification of Autoantibody Recurrence in Patients With Membranous Nephropathy

Circulating autoantibodies against the M-type phospholipase A2 receptor 1 (PLA2R1) are important biomarkers in membranous nephropathy (MN), supporting the diagnosis and the clinical monitoring of patients. Standardized recombinant cell-based indirect immunofluorescence assay (RC-IFA) and enzyme-link...

Full description

Saved in:
Bibliographic Details
Published in:Kidney international reports 2021-04, Vol.6 (4), p.928-935
Main Authors: Hoxha, Elion, Stahl, Rolf A.K., Reinhard, Linda, Kühnl, Alexander, Schlumberger, Wolfgang, Dähnrich, Cornelia
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Circulating autoantibodies against the M-type phospholipase A2 receptor 1 (PLA2R1) are important biomarkers in membranous nephropathy (MN), supporting the diagnosis and the clinical monitoring of patients. Standardized recombinant cell-based indirect immunofluorescence assay (RC-IFA) and enzyme-linked immunosorbent assay (ELISA) are widely established for the detection of anti-PLA2R1 autoantibodies (PLA2R1-ab). The RC-IFA provides higher sensitivity than the ELISA, but lacks exact graduated quantification of antibody levels. In this study, we evaluated the diagnostic performance of a novel PLA2R1-ab immunoassay based on chemiluminescence (ChLIA) by comparing it to RC-IFA and ELISA in samples from patients with MN with different diagnostic scenarios. Serum samples from patients with biopsy-proven MN and disease controls were analyzed for PLA2R1-ab by ChLIA, ELISA, and RC-IFA. The ChLIA demonstrated almost perfect agreement with RC-IFA for the identification of patients with PLA2R1-associated MN, while additionally allowing fine-graduated quantification of PLA2R1-ab levels. In patients with a relapse of MN, the ChLIA allowed an earlier detection of PLA2R1-ab recurrence by at least 3 months in 63% of cases compared with the ELISA. The PLA2R1-ab ChLIA had the same excellent diagnostic performance as the RC-IFA and outperformed the ELISA in the diagnosis of MN and the early identification of relapses. It thus presents a favorable tool for accurate PLA2R1-ab assessment in routine diagnostic settings, while enabling fast processing and fully automated random-access implementation. [Display omitted]