Loading…
Spraying performance and deposition characteristics of an improved air-assisted nozzle with induction charging
Electrostatic spraying technology can improve the efficiency of pesticide deposition on the surface of leaves and reduce the environmental pollution caused by pesticide drift, which has an important prospect in agricultural pesticide application. To improve the deposition and penetration of droplets...
Saved in:
Published in: | Frontiers in plant science 2024, Vol.15, p.1309088-1309088 |
---|---|
Main Authors: | , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Electrostatic spraying technology can improve the efficiency of pesticide deposition on the surface of leaves and reduce the environmental pollution caused by pesticide drift, which has an important prospect in agricultural pesticide application. To improve the deposition and penetration of droplets in the crop canopy, we designed and optimized an air-assisted electrostatic nozzle and conducted the spraying performance experiment. Parameters, such as charge-to-mass ratio (CMR) and particle size, were tested and analyzed to obtain the suitable operating parameters of nozzle. The results proved that the improved air-assisted electrostatic nozzle has good atomization and chargeability. There is a good charging effect with a charging voltage of 3,000-5,000 V, the CMR increased 127.8% from 0.86 to 1.97 mC/kg as the charge voltage increases from 1,000 to 4,000 V, at an air pressure of 1.0 bar and liquid flow rate of 200 ml/min. Furthermore, we designed a multi-factor orthogonal experiment, which was conducted using a four-factor, three-level design to investigate the effects of operational parameters and canopy characteristics on droplet deposition and penetration. Analysis of variance (ANOVA) and F-test were performed on the experiment results. The results showed that the factor effect on droplet penetration, in descending order, was as follows: spray distance, leaf area index, air pressure, and air pressure × spray distance. The factor effect on abaxial leaf deposition, in descending order, was as follows: air pressure, spray distance, air pressure × charge voltage, spray distance × charge voltage, and charge voltage. For optimal droplet penetration and abaxial leaf deposition, option
(air pressure 1.5 bar, spray distance 0.2 m, charge voltage 2,500 V) is recommend. The spray nozzle atomization performance and deposition regulation were studied by experimental methods to determine the optimal values of operating parameters to provide a reference for electrostatic spray system development. |
---|---|
ISSN: | 1664-462X 1664-462X |
DOI: | 10.3389/fpls.2024.1309088 |