Loading…
Reliability of Hand-Held Transcranial Doppler with M-mode Ultrasound in Middle Cerebral Artery Measurement
To determine the intra- and interrater agreement of mean flow velocity (MFV) and pulsatility index (PI) measurement in middle cerebral arteries, assessed by transcranial Doppler (TCD) with M-mode. Masked experienced neurosonologists performed TCD with M-mode using handheld probe in healthy adult vol...
Saved in:
Published in: | Journal of medical ultrasound 2017-06, Vol.25 (2), p.76-81 |
---|---|
Main Authors: | , , , , , , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c517t-edb7df4740815386821cbba7c7b620c0631477d45a55558cf7c3f1d82dd18e2c3 |
---|---|
cites | cdi_FETCH-LOGICAL-c517t-edb7df4740815386821cbba7c7b620c0631477d45a55558cf7c3f1d82dd18e2c3 |
container_end_page | 81 |
container_issue | 2 |
container_start_page | 76 |
container_title | Journal of medical ultrasound |
container_volume | 25 |
creator | Muñoz Venturelli, Paula Brunser, Alejandro M. Gaete, Javier Illanes, Sergio López, Javiera Olavarría, Verónica V. Reccius, Andrés Brinck, Pablo González, Francisca Cavada, Gabriel Lavados, Pablo M. |
description | To determine the intra- and interrater agreement of mean flow velocity (MFV) and pulsatility index (PI) measurement in middle cerebral arteries, assessed by transcranial Doppler (TCD) with M-mode.
Masked experienced neurosonologists performed TCD with M-mode using handheld probe in healthy adult volunteers. The Bland–Altman method for concordance and intraclass correlation coefficient were used.
Seventy-seven healthy volunteers and seven raters participated (3 on regular TCD shift and 4 off-shift). The intrarater absolute mean difference between measurements was 5.5 cm/s [95% confidence interval (CI), 4.7–6.3] for MVF and 0.073 (95% CI, 0.063–0.083) for PI. The difference between MFV measurements was significantly higher in off-shift raters (p=0.015). The interrater absolute mean difference between measurements was 6.5 cm/s (95% CI, 5.5–7.5) for MVF and 0.065 (95% CI, 0.059–0.071) for PI. No influence was found for the middle cerebral artery side, volunteer's sex, or age, and there was no significant difference between raters. The intraclass correlation coefficient was 82.2% (95% CI 77.8–85.6) and 72.9% (95% CI 67.4–77.6) for MFV and PI, respectively.
There exists good intra- and interrater agreement in MFV and PI measurements using M-mode TCD. These results support the use of this noninvasive tool and are important for clinical and investigational purposes. |
doi_str_mv | 10.1016/j.jmu.2016.12.001 |
format | article |
fullrecord | <record><control><sourceid>proquest_doaj_</sourceid><recordid>TN_cdi_doaj_primary_oai_doaj_org_article_9cc52e0b5daa43a79bd7f202b2f8881d</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0929644116300935</els_id><doaj_id>oai_doaj_org_article_9cc52e0b5daa43a79bd7f202b2f8881d</doaj_id><sourcerecordid>2081542297</sourcerecordid><originalsourceid>FETCH-LOGICAL-c517t-edb7df4740815386821cbba7c7b620c0631477d45a55558cf7c3f1d82dd18e2c3</originalsourceid><addsrcrecordid>eNp9kc1u3CAUhVHVqpmmfYBuKpbdeArX2NiqVCma_kykjCpVyRphuE6wsJmCnWrevkwnjZpNWQCCcz649xDylrM1Z7z-MKyHcVlD3q45rBnjz8gKgEPBqwqekxVroS1qIfgZeZXSwJio21a8JGclY3UlarEiww_0TnfOu_lAQ0-3erLFFr2l11FPyeTJaU8_h_3eY6S_3HxHd8UYLNIbP0edwjJZ6ia6c9Z6pBuM2MXsuIgzxgPdoU5LxBGn-TV50Wuf8M3Dek5uvn653myLq-_fLjcXV4WpuJwLtJ20vZCCNbwqm7oBbrpOSyO7GphhdcmFlFZUusqjMb00Zc9tA9byBsGU5-TyxLVBD2of3ajjQQXt1J-DEG-VjrMzHlVrTAXIuspqLUot287KHhh00DdNw21mfTqx9ks3ojW5jFzcE-jTm8ndqdtwr2oGbcllBrx_AMTwc8E0q9Elg97rCcOSFByrFADtUcpPUhNDShH7x2c4U8e81aBy3uqYt-Kgct7Z8-7f_z06_gacBR9PAswdv3cYVTIOJ4PWRTRzbon7D_43o2-8yg</addsrcrecordid><sourcetype>Open Website</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2081542297</pqid></control><display><type>article</type><title>Reliability of Hand-Held Transcranial Doppler with M-mode Ultrasound in Middle Cerebral Artery Measurement</title><source>PubMed Central(OpenAccess)</source><creator>Muñoz Venturelli, Paula ; Brunser, Alejandro M. ; Gaete, Javier ; Illanes, Sergio ; López, Javiera ; Olavarría, Verónica V. ; Reccius, Andrés ; Brinck, Pablo ; González, Francisca ; Cavada, Gabriel ; Lavados, Pablo M.</creator><creatorcontrib>Muñoz Venturelli, Paula ; Brunser, Alejandro M. ; Gaete, Javier ; Illanes, Sergio ; López, Javiera ; Olavarría, Verónica V. ; Reccius, Andrés ; Brinck, Pablo ; González, Francisca ; Cavada, Gabriel ; Lavados, Pablo M.</creatorcontrib><description>To determine the intra- and interrater agreement of mean flow velocity (MFV) and pulsatility index (PI) measurement in middle cerebral arteries, assessed by transcranial Doppler (TCD) with M-mode.
Masked experienced neurosonologists performed TCD with M-mode using handheld probe in healthy adult volunteers. The Bland–Altman method for concordance and intraclass correlation coefficient were used.
Seventy-seven healthy volunteers and seven raters participated (3 on regular TCD shift and 4 off-shift). The intrarater absolute mean difference between measurements was 5.5 cm/s [95% confidence interval (CI), 4.7–6.3] for MVF and 0.073 (95% CI, 0.063–0.083) for PI. The difference between MFV measurements was significantly higher in off-shift raters (p=0.015). The interrater absolute mean difference between measurements was 6.5 cm/s (95% CI, 5.5–7.5) for MVF and 0.065 (95% CI, 0.059–0.071) for PI. No influence was found for the middle cerebral artery side, volunteer's sex, or age, and there was no significant difference between raters. The intraclass correlation coefficient was 82.2% (95% CI 77.8–85.6) and 72.9% (95% CI 67.4–77.6) for MFV and PI, respectively.
There exists good intra- and interrater agreement in MFV and PI measurements using M-mode TCD. These results support the use of this noninvasive tool and are important for clinical and investigational purposes.</description><identifier>ISSN: 0929-6441</identifier><identifier>EISSN: 2212-1552</identifier><identifier>DOI: 10.1016/j.jmu.2016.12.001</identifier><identifier>PMID: 30065464</identifier><language>eng</language><publisher>India: Elsevier Taiwan LLC</publisher><subject>agreement ; intraclass correlation coefficient ; mean flow velocity ; Original ; reproducibility ; transcranial Doppler</subject><ispartof>Journal of medical ultrasound, 2017-06, Vol.25 (2), p.76-81</ispartof><rights>2017</rights><rights>Copyright: © 2017, Elsevier Taiwan LLC and the Chinese Taipei Society of Ultrasound in Medicine 2017</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c517t-edb7df4740815386821cbba7c7b620c0631477d45a55558cf7c3f1d82dd18e2c3</citedby><cites>FETCH-LOGICAL-c517t-edb7df4740815386821cbba7c7b620c0631477d45a55558cf7c3f1d82dd18e2c3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC6029317/pdf/$$EPDF$$P50$$Gpubmedcentral$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC6029317/$$EHTML$$P50$$Gpubmedcentral$$Hfree_for_read</linktohtml><link.rule.ids>230,314,727,780,784,885,27924,27925,53791,53793</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/30065464$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Muñoz Venturelli, Paula</creatorcontrib><creatorcontrib>Brunser, Alejandro M.</creatorcontrib><creatorcontrib>Gaete, Javier</creatorcontrib><creatorcontrib>Illanes, Sergio</creatorcontrib><creatorcontrib>López, Javiera</creatorcontrib><creatorcontrib>Olavarría, Verónica V.</creatorcontrib><creatorcontrib>Reccius, Andrés</creatorcontrib><creatorcontrib>Brinck, Pablo</creatorcontrib><creatorcontrib>González, Francisca</creatorcontrib><creatorcontrib>Cavada, Gabriel</creatorcontrib><creatorcontrib>Lavados, Pablo M.</creatorcontrib><title>Reliability of Hand-Held Transcranial Doppler with M-mode Ultrasound in Middle Cerebral Artery Measurement</title><title>Journal of medical ultrasound</title><addtitle>J Med Ultrasound</addtitle><description>To determine the intra- and interrater agreement of mean flow velocity (MFV) and pulsatility index (PI) measurement in middle cerebral arteries, assessed by transcranial Doppler (TCD) with M-mode.
Masked experienced neurosonologists performed TCD with M-mode using handheld probe in healthy adult volunteers. The Bland–Altman method for concordance and intraclass correlation coefficient were used.
Seventy-seven healthy volunteers and seven raters participated (3 on regular TCD shift and 4 off-shift). The intrarater absolute mean difference between measurements was 5.5 cm/s [95% confidence interval (CI), 4.7–6.3] for MVF and 0.073 (95% CI, 0.063–0.083) for PI. The difference between MFV measurements was significantly higher in off-shift raters (p=0.015). The interrater absolute mean difference between measurements was 6.5 cm/s (95% CI, 5.5–7.5) for MVF and 0.065 (95% CI, 0.059–0.071) for PI. No influence was found for the middle cerebral artery side, volunteer's sex, or age, and there was no significant difference between raters. The intraclass correlation coefficient was 82.2% (95% CI 77.8–85.6) and 72.9% (95% CI 67.4–77.6) for MFV and PI, respectively.
There exists good intra- and interrater agreement in MFV and PI measurements using M-mode TCD. These results support the use of this noninvasive tool and are important for clinical and investigational purposes.</description><subject>agreement</subject><subject>intraclass correlation coefficient</subject><subject>mean flow velocity</subject><subject>Original</subject><subject>reproducibility</subject><subject>transcranial Doppler</subject><issn>0929-6441</issn><issn>2212-1552</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2017</creationdate><recordtype>article</recordtype><sourceid>DOA</sourceid><recordid>eNp9kc1u3CAUhVHVqpmmfYBuKpbdeArX2NiqVCma_kykjCpVyRphuE6wsJmCnWrevkwnjZpNWQCCcz649xDylrM1Z7z-MKyHcVlD3q45rBnjz8gKgEPBqwqekxVroS1qIfgZeZXSwJio21a8JGclY3UlarEiww_0TnfOu_lAQ0-3erLFFr2l11FPyeTJaU8_h_3eY6S_3HxHd8UYLNIbP0edwjJZ6ia6c9Z6pBuM2MXsuIgzxgPdoU5LxBGn-TV50Wuf8M3Dek5uvn653myLq-_fLjcXV4WpuJwLtJ20vZCCNbwqm7oBbrpOSyO7GphhdcmFlFZUusqjMb00Zc9tA9byBsGU5-TyxLVBD2of3ajjQQXt1J-DEG-VjrMzHlVrTAXIuspqLUot287KHhh00DdNw21mfTqx9ks3ojW5jFzcE-jTm8ndqdtwr2oGbcllBrx_AMTwc8E0q9Elg97rCcOSFByrFADtUcpPUhNDShH7x2c4U8e81aBy3uqYt-Kgct7Z8-7f_z06_gacBR9PAswdv3cYVTIOJ4PWRTRzbon7D_43o2-8yg</recordid><startdate>20170601</startdate><enddate>20170601</enddate><creator>Muñoz Venturelli, Paula</creator><creator>Brunser, Alejandro M.</creator><creator>Gaete, Javier</creator><creator>Illanes, Sergio</creator><creator>López, Javiera</creator><creator>Olavarría, Verónica V.</creator><creator>Reccius, Andrés</creator><creator>Brinck, Pablo</creator><creator>González, Francisca</creator><creator>Cavada, Gabriel</creator><creator>Lavados, Pablo M.</creator><general>Elsevier Taiwan LLC</general><general>Medknow Publications & Media Pvt Ltd</general><general>Wolters Kluwer Medknow Publications</general><scope>6I.</scope><scope>AAFTH</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>5PM</scope><scope>DOA</scope></search><sort><creationdate>20170601</creationdate><title>Reliability of Hand-Held Transcranial Doppler with M-mode Ultrasound in Middle Cerebral Artery Measurement</title><author>Muñoz Venturelli, Paula ; Brunser, Alejandro M. ; Gaete, Javier ; Illanes, Sergio ; López, Javiera ; Olavarría, Verónica V. ; Reccius, Andrés ; Brinck, Pablo ; González, Francisca ; Cavada, Gabriel ; Lavados, Pablo M.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c517t-edb7df4740815386821cbba7c7b620c0631477d45a55558cf7c3f1d82dd18e2c3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2017</creationdate><topic>agreement</topic><topic>intraclass correlation coefficient</topic><topic>mean flow velocity</topic><topic>Original</topic><topic>reproducibility</topic><topic>transcranial Doppler</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Muñoz Venturelli, Paula</creatorcontrib><creatorcontrib>Brunser, Alejandro M.</creatorcontrib><creatorcontrib>Gaete, Javier</creatorcontrib><creatorcontrib>Illanes, Sergio</creatorcontrib><creatorcontrib>López, Javiera</creatorcontrib><creatorcontrib>Olavarría, Verónica V.</creatorcontrib><creatorcontrib>Reccius, Andrés</creatorcontrib><creatorcontrib>Brinck, Pablo</creatorcontrib><creatorcontrib>González, Francisca</creatorcontrib><creatorcontrib>Cavada, Gabriel</creatorcontrib><creatorcontrib>Lavados, Pablo M.</creatorcontrib><collection>ScienceDirect Open Access Titles</collection><collection>Elsevier:ScienceDirect:Open Access</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><collection>Directory of Open Access Journals</collection><jtitle>Journal of medical ultrasound</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Muñoz Venturelli, Paula</au><au>Brunser, Alejandro M.</au><au>Gaete, Javier</au><au>Illanes, Sergio</au><au>López, Javiera</au><au>Olavarría, Verónica V.</au><au>Reccius, Andrés</au><au>Brinck, Pablo</au><au>González, Francisca</au><au>Cavada, Gabriel</au><au>Lavados, Pablo M.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Reliability of Hand-Held Transcranial Doppler with M-mode Ultrasound in Middle Cerebral Artery Measurement</atitle><jtitle>Journal of medical ultrasound</jtitle><addtitle>J Med Ultrasound</addtitle><date>2017-06-01</date><risdate>2017</risdate><volume>25</volume><issue>2</issue><spage>76</spage><epage>81</epage><pages>76-81</pages><issn>0929-6441</issn><eissn>2212-1552</eissn><abstract>To determine the intra- and interrater agreement of mean flow velocity (MFV) and pulsatility index (PI) measurement in middle cerebral arteries, assessed by transcranial Doppler (TCD) with M-mode.
Masked experienced neurosonologists performed TCD with M-mode using handheld probe in healthy adult volunteers. The Bland–Altman method for concordance and intraclass correlation coefficient were used.
Seventy-seven healthy volunteers and seven raters participated (3 on regular TCD shift and 4 off-shift). The intrarater absolute mean difference between measurements was 5.5 cm/s [95% confidence interval (CI), 4.7–6.3] for MVF and 0.073 (95% CI, 0.063–0.083) for PI. The difference between MFV measurements was significantly higher in off-shift raters (p=0.015). The interrater absolute mean difference between measurements was 6.5 cm/s (95% CI, 5.5–7.5) for MVF and 0.065 (95% CI, 0.059–0.071) for PI. No influence was found for the middle cerebral artery side, volunteer's sex, or age, and there was no significant difference between raters. The intraclass correlation coefficient was 82.2% (95% CI 77.8–85.6) and 72.9% (95% CI 67.4–77.6) for MFV and PI, respectively.
There exists good intra- and interrater agreement in MFV and PI measurements using M-mode TCD. These results support the use of this noninvasive tool and are important for clinical and investigational purposes.</abstract><cop>India</cop><pub>Elsevier Taiwan LLC</pub><pmid>30065464</pmid><doi>10.1016/j.jmu.2016.12.001</doi><tpages>6</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0929-6441 |
ispartof | Journal of medical ultrasound, 2017-06, Vol.25 (2), p.76-81 |
issn | 0929-6441 2212-1552 |
language | eng |
recordid | cdi_doaj_primary_oai_doaj_org_article_9cc52e0b5daa43a79bd7f202b2f8881d |
source | PubMed Central(OpenAccess) |
subjects | agreement intraclass correlation coefficient mean flow velocity Original reproducibility transcranial Doppler |
title | Reliability of Hand-Held Transcranial Doppler with M-mode Ultrasound in Middle Cerebral Artery Measurement |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-26T05%3A18%3A00IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_doaj_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Reliability%20of%20Hand-Held%20Transcranial%20Doppler%20with%20M-mode%20Ultrasound%20in%20Middle%20Cerebral%20Artery%20Measurement&rft.jtitle=Journal%20of%20medical%20ultrasound&rft.au=Mu%C3%B1oz%20Venturelli,%20Paula&rft.date=2017-06-01&rft.volume=25&rft.issue=2&rft.spage=76&rft.epage=81&rft.pages=76-81&rft.issn=0929-6441&rft.eissn=2212-1552&rft_id=info:doi/10.1016/j.jmu.2016.12.001&rft_dat=%3Cproquest_doaj_%3E2081542297%3C/proquest_doaj_%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c517t-edb7df4740815386821cbba7c7b620c0631477d45a55558cf7c3f1d82dd18e2c3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2081542297&rft_id=info:pmid/30065464&rfr_iscdi=true |