Loading…
Autoencoder-Based Extrasystole Detection and Modification of RRI Data for Precise Heart Rate Variability Analysis
Heart rate variability, which is the fluctuation of the R-R interval (RRI) in electrocardiograms (ECG), has been widely adopted for autonomous evaluation. Since the HRV features that are extracted from RRI data easily fluctuate when arrhythmia occurs, RRI data with arrhythmia need to be modified app...
Saved in:
Published in: | Sensors (Basel, Switzerland) Switzerland), 2021-05, Vol.21 (9), p.3235 |
---|---|
Main Authors: | , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c512t-8da3f58b0f00e44643003894c2250479a4ad5a475efcf086a194956ba9dcfef73 |
---|---|
cites | cdi_FETCH-LOGICAL-c512t-8da3f58b0f00e44643003894c2250479a4ad5a475efcf086a194956ba9dcfef73 |
container_end_page | |
container_issue | 9 |
container_start_page | 3235 |
container_title | Sensors (Basel, Switzerland) |
container_volume | 21 |
creator | Fujiwara, Koichi Miyatani, Shota Goda, Asuka Miyajima, Miho Sasano, Tetsuo Kano, Manabu |
description | Heart rate variability, which is the fluctuation of the R-R interval (RRI) in electrocardiograms (ECG), has been widely adopted for autonomous evaluation. Since the HRV features that are extracted from RRI data easily fluctuate when arrhythmia occurs, RRI data with arrhythmia need to be modified appropriately before HRV analysis. In this study, we consider two types of extrasystoles—premature ventricular contraction (PVC) and premature atrial contraction (PAC)—which are types of extrasystoles that occur every day, even in healthy persons who have no cardiovascular diseases. A unified framework for ectopic RRI detection and a modification algorithm that utilizes an autoencoder (AE) type of neural network is proposed. The proposed framework consists of extrasystole occurrence detection from the RRI data and modification, whose targets are PVC and PAC. The RRI data are monitored by means of the AE in real time in the detection phase, and a denoising autoencoder (DAE) modifies the ectopic RRI caused by the detected extrasystole. These are referred to as AE-based extrasystole detection (AED) and DAE-based extrasystole modification (DAEM), respectively. The proposed framework was applied to real RRI data with PVC and PAC. The result showed that AED achieved a sensitivity of 93% and a false positive rate of 0.08 times per hour. The root mean squared error of the modified RRI decreased to 31% in PVC and 73% in PAC from the original RRI data by DAEM. In addition, the proposed framework was validated through application to a clinical epileptic seizure problem, which showed that it correctly suppressed the false positives caused by PVC. Thus, the proposed framework can contribute to realizing accurate HRV-based health monitoring and medical sensing systems. |
doi_str_mv | 10.3390/s21093235 |
format | article |
fullrecord | <record><control><sourceid>proquest_doaj_</sourceid><recordid>TN_cdi_doaj_primary_oai_doaj_org_article_9e8967469dd14332817de476a0403cbf</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><doaj_id>oai_doaj_org_article_9e8967469dd14332817de476a0403cbf</doaj_id><sourcerecordid>2530161027</sourcerecordid><originalsourceid>FETCH-LOGICAL-c512t-8da3f58b0f00e44643003894c2250479a4ad5a475efcf086a194956ba9dcfef73</originalsourceid><addsrcrecordid>eNpdkk1vFDEMhiMEomXhwD-IxAUOU_I1mZkL0vaDdqUi0Aq4Rp7EKVnNTtokg9h_z3S3qignW_arx68tE_KWsxMpO_YxC846KWT9jBxzJVTVCsGe_5MfkVc5bxgTUsr2JTmSiumG1fyY3C2nEnG00WGqTiGjoxd_SoK8yyUOSM-xoC0hjhRGR79EF3ywsC9ET9frFT2HAtTHRL8ltCEjvUJIha6hIP0JKUAfhlB2dDnCsMshvyYvPAwZ3zzEBfnx-eL72VV1_fVydba8rmzNRalaB9LXbc88Y6iUVpIx2XbKClEz1XSgwNWgmhq99azVwDvV1bqHzlmPvpELsjpwXYSNuU1hC2lnIgSzL8R0Y2afwQ5oOmw73SjdOceVlKLljUPVaGCKSdv7mfXpwLqd-i06i-N8ouEJ9GlnDL_MTfxtWj671XwGvH8ApHg3YS5mG7LFYYAR45SNqKVWDa_n8Qvy7j_pJk5pPt5exbjmTNxv9-GgsinmnNA_muHM3D-FeXwK-RfZjKcu</addsrcrecordid><sourcetype>Open Website</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2530161027</pqid></control><display><type>article</type><title>Autoencoder-Based Extrasystole Detection and Modification of RRI Data for Precise Heart Rate Variability Analysis</title><source>Open Access: PubMed Central</source><source>Publicly Available Content Database</source><creator>Fujiwara, Koichi ; Miyatani, Shota ; Goda, Asuka ; Miyajima, Miho ; Sasano, Tetsuo ; Kano, Manabu</creator><creatorcontrib>Fujiwara, Koichi ; Miyatani, Shota ; Goda, Asuka ; Miyajima, Miho ; Sasano, Tetsuo ; Kano, Manabu</creatorcontrib><description>Heart rate variability, which is the fluctuation of the R-R interval (RRI) in electrocardiograms (ECG), has been widely adopted for autonomous evaluation. Since the HRV features that are extracted from RRI data easily fluctuate when arrhythmia occurs, RRI data with arrhythmia need to be modified appropriately before HRV analysis. In this study, we consider two types of extrasystoles—premature ventricular contraction (PVC) and premature atrial contraction (PAC)—which are types of extrasystoles that occur every day, even in healthy persons who have no cardiovascular diseases. A unified framework for ectopic RRI detection and a modification algorithm that utilizes an autoencoder (AE) type of neural network is proposed. The proposed framework consists of extrasystole occurrence detection from the RRI data and modification, whose targets are PVC and PAC. The RRI data are monitored by means of the AE in real time in the detection phase, and a denoising autoencoder (DAE) modifies the ectopic RRI caused by the detected extrasystole. These are referred to as AE-based extrasystole detection (AED) and DAE-based extrasystole modification (DAEM), respectively. The proposed framework was applied to real RRI data with PVC and PAC. The result showed that AED achieved a sensitivity of 93% and a false positive rate of 0.08 times per hour. The root mean squared error of the modified RRI decreased to 31% in PVC and 73% in PAC from the original RRI data by DAEM. In addition, the proposed framework was validated through application to a clinical epileptic seizure problem, which showed that it correctly suppressed the false positives caused by PVC. Thus, the proposed framework can contribute to realizing accurate HRV-based health monitoring and medical sensing systems.</description><identifier>ISSN: 1424-8220</identifier><identifier>EISSN: 1424-8220</identifier><identifier>DOI: 10.3390/s21093235</identifier><identifier>PMID: 34067051</identifier><language>eng</language><publisher>Basel: MDPI AG</publisher><subject>Algorithms ; Arrhythmia ; autoencoder ; Cardiac arrhythmia ; Convulsions & seizures ; Electrocardiography ; Epilepsy ; extrasystole ; Failure ; Heart rate ; heart rate variability analysis ; machine learning ; Neural networks ; Noise reduction ; RRI data ; Seizures ; Sensors ; Sinuses ; Sleep ; Software</subject><ispartof>Sensors (Basel, Switzerland), 2021-05, Vol.21 (9), p.3235</ispartof><rights>2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.</rights><rights>2021 by the authors. 2021</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c512t-8da3f58b0f00e44643003894c2250479a4ad5a475efcf086a194956ba9dcfef73</citedby><cites>FETCH-LOGICAL-c512t-8da3f58b0f00e44643003894c2250479a4ad5a475efcf086a194956ba9dcfef73</cites><orcidid>0000-0002-2929-0561 ; 0000-0002-2325-1043</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.proquest.com/docview/2530161027/fulltextPDF?pq-origsite=primo$$EPDF$$P50$$Gproquest$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.proquest.com/docview/2530161027?pq-origsite=primo$$EHTML$$P50$$Gproquest$$Hfree_for_read</linktohtml><link.rule.ids>230,314,727,780,784,885,25752,27923,27924,37011,37012,44589,53790,53792,74997</link.rule.ids></links><search><creatorcontrib>Fujiwara, Koichi</creatorcontrib><creatorcontrib>Miyatani, Shota</creatorcontrib><creatorcontrib>Goda, Asuka</creatorcontrib><creatorcontrib>Miyajima, Miho</creatorcontrib><creatorcontrib>Sasano, Tetsuo</creatorcontrib><creatorcontrib>Kano, Manabu</creatorcontrib><title>Autoencoder-Based Extrasystole Detection and Modification of RRI Data for Precise Heart Rate Variability Analysis</title><title>Sensors (Basel, Switzerland)</title><description>Heart rate variability, which is the fluctuation of the R-R interval (RRI) in electrocardiograms (ECG), has been widely adopted for autonomous evaluation. Since the HRV features that are extracted from RRI data easily fluctuate when arrhythmia occurs, RRI data with arrhythmia need to be modified appropriately before HRV analysis. In this study, we consider two types of extrasystoles—premature ventricular contraction (PVC) and premature atrial contraction (PAC)—which are types of extrasystoles that occur every day, even in healthy persons who have no cardiovascular diseases. A unified framework for ectopic RRI detection and a modification algorithm that utilizes an autoencoder (AE) type of neural network is proposed. The proposed framework consists of extrasystole occurrence detection from the RRI data and modification, whose targets are PVC and PAC. The RRI data are monitored by means of the AE in real time in the detection phase, and a denoising autoencoder (DAE) modifies the ectopic RRI caused by the detected extrasystole. These are referred to as AE-based extrasystole detection (AED) and DAE-based extrasystole modification (DAEM), respectively. The proposed framework was applied to real RRI data with PVC and PAC. The result showed that AED achieved a sensitivity of 93% and a false positive rate of 0.08 times per hour. The root mean squared error of the modified RRI decreased to 31% in PVC and 73% in PAC from the original RRI data by DAEM. In addition, the proposed framework was validated through application to a clinical epileptic seizure problem, which showed that it correctly suppressed the false positives caused by PVC. Thus, the proposed framework can contribute to realizing accurate HRV-based health monitoring and medical sensing systems.</description><subject>Algorithms</subject><subject>Arrhythmia</subject><subject>autoencoder</subject><subject>Cardiac arrhythmia</subject><subject>Convulsions & seizures</subject><subject>Electrocardiography</subject><subject>Epilepsy</subject><subject>extrasystole</subject><subject>Failure</subject><subject>Heart rate</subject><subject>heart rate variability analysis</subject><subject>machine learning</subject><subject>Neural networks</subject><subject>Noise reduction</subject><subject>RRI data</subject><subject>Seizures</subject><subject>Sensors</subject><subject>Sinuses</subject><subject>Sleep</subject><subject>Software</subject><issn>1424-8220</issn><issn>1424-8220</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2021</creationdate><recordtype>article</recordtype><sourceid>PIMPY</sourceid><sourceid>DOA</sourceid><recordid>eNpdkk1vFDEMhiMEomXhwD-IxAUOU_I1mZkL0vaDdqUi0Aq4Rp7EKVnNTtokg9h_z3S3qignW_arx68tE_KWsxMpO_YxC846KWT9jBxzJVTVCsGe_5MfkVc5bxgTUsr2JTmSiumG1fyY3C2nEnG00WGqTiGjoxd_SoK8yyUOSM-xoC0hjhRGR79EF3ywsC9ET9frFT2HAtTHRL8ltCEjvUJIha6hIP0JKUAfhlB2dDnCsMshvyYvPAwZ3zzEBfnx-eL72VV1_fVydba8rmzNRalaB9LXbc88Y6iUVpIx2XbKClEz1XSgwNWgmhq99azVwDvV1bqHzlmPvpELsjpwXYSNuU1hC2lnIgSzL8R0Y2afwQ5oOmw73SjdOceVlKLljUPVaGCKSdv7mfXpwLqd-i06i-N8ouEJ9GlnDL_MTfxtWj671XwGvH8ApHg3YS5mG7LFYYAR45SNqKVWDa_n8Qvy7j_pJk5pPt5exbjmTNxv9-GgsinmnNA_muHM3D-FeXwK-RfZjKcu</recordid><startdate>20210507</startdate><enddate>20210507</enddate><creator>Fujiwara, Koichi</creator><creator>Miyatani, Shota</creator><creator>Goda, Asuka</creator><creator>Miyajima, Miho</creator><creator>Sasano, Tetsuo</creator><creator>Kano, Manabu</creator><general>MDPI AG</general><general>MDPI</general><scope>AAYXX</scope><scope>CITATION</scope><scope>3V.</scope><scope>7X7</scope><scope>7XB</scope><scope>88E</scope><scope>8FI</scope><scope>8FJ</scope><scope>8FK</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>FYUFA</scope><scope>GHDGH</scope><scope>K9.</scope><scope>M0S</scope><scope>M1P</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>7X8</scope><scope>5PM</scope><scope>DOA</scope><orcidid>https://orcid.org/0000-0002-2929-0561</orcidid><orcidid>https://orcid.org/0000-0002-2325-1043</orcidid></search><sort><creationdate>20210507</creationdate><title>Autoencoder-Based Extrasystole Detection and Modification of RRI Data for Precise Heart Rate Variability Analysis</title><author>Fujiwara, Koichi ; Miyatani, Shota ; Goda, Asuka ; Miyajima, Miho ; Sasano, Tetsuo ; Kano, Manabu</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c512t-8da3f58b0f00e44643003894c2250479a4ad5a475efcf086a194956ba9dcfef73</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2021</creationdate><topic>Algorithms</topic><topic>Arrhythmia</topic><topic>autoencoder</topic><topic>Cardiac arrhythmia</topic><topic>Convulsions & seizures</topic><topic>Electrocardiography</topic><topic>Epilepsy</topic><topic>extrasystole</topic><topic>Failure</topic><topic>Heart rate</topic><topic>heart rate variability analysis</topic><topic>machine learning</topic><topic>Neural networks</topic><topic>Noise reduction</topic><topic>RRI data</topic><topic>Seizures</topic><topic>Sensors</topic><topic>Sinuses</topic><topic>Sleep</topic><topic>Software</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Fujiwara, Koichi</creatorcontrib><creatorcontrib>Miyatani, Shota</creatorcontrib><creatorcontrib>Goda, Asuka</creatorcontrib><creatorcontrib>Miyajima, Miho</creatorcontrib><creatorcontrib>Sasano, Tetsuo</creatorcontrib><creatorcontrib>Kano, Manabu</creatorcontrib><collection>CrossRef</collection><collection>ProQuest Central (Corporate)</collection><collection>Health & Medical Collection</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>Medical Database (Alumni Edition)</collection><collection>Hospital Premium Collection</collection><collection>Hospital Premium Collection (Alumni Edition)</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>ProQuest Central (Alumni)</collection><collection>ProQuest Central</collection><collection>ProQuest Central Essentials</collection><collection>AUTh Library subscriptions: ProQuest Central</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central Korea</collection><collection>Health Research Premium Collection</collection><collection>Health Research Premium Collection (Alumni)</collection><collection>ProQuest Health & Medical Complete (Alumni)</collection><collection>Health & Medical Collection (Alumni Edition)</collection><collection>Medical Database</collection><collection>Publicly Available Content Database</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><collection>DOAJ Directory of Open Access Journals</collection><jtitle>Sensors (Basel, Switzerland)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Fujiwara, Koichi</au><au>Miyatani, Shota</au><au>Goda, Asuka</au><au>Miyajima, Miho</au><au>Sasano, Tetsuo</au><au>Kano, Manabu</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Autoencoder-Based Extrasystole Detection and Modification of RRI Data for Precise Heart Rate Variability Analysis</atitle><jtitle>Sensors (Basel, Switzerland)</jtitle><date>2021-05-07</date><risdate>2021</risdate><volume>21</volume><issue>9</issue><spage>3235</spage><pages>3235-</pages><issn>1424-8220</issn><eissn>1424-8220</eissn><abstract>Heart rate variability, which is the fluctuation of the R-R interval (RRI) in electrocardiograms (ECG), has been widely adopted for autonomous evaluation. Since the HRV features that are extracted from RRI data easily fluctuate when arrhythmia occurs, RRI data with arrhythmia need to be modified appropriately before HRV analysis. In this study, we consider two types of extrasystoles—premature ventricular contraction (PVC) and premature atrial contraction (PAC)—which are types of extrasystoles that occur every day, even in healthy persons who have no cardiovascular diseases. A unified framework for ectopic RRI detection and a modification algorithm that utilizes an autoencoder (AE) type of neural network is proposed. The proposed framework consists of extrasystole occurrence detection from the RRI data and modification, whose targets are PVC and PAC. The RRI data are monitored by means of the AE in real time in the detection phase, and a denoising autoencoder (DAE) modifies the ectopic RRI caused by the detected extrasystole. These are referred to as AE-based extrasystole detection (AED) and DAE-based extrasystole modification (DAEM), respectively. The proposed framework was applied to real RRI data with PVC and PAC. The result showed that AED achieved a sensitivity of 93% and a false positive rate of 0.08 times per hour. The root mean squared error of the modified RRI decreased to 31% in PVC and 73% in PAC from the original RRI data by DAEM. In addition, the proposed framework was validated through application to a clinical epileptic seizure problem, which showed that it correctly suppressed the false positives caused by PVC. Thus, the proposed framework can contribute to realizing accurate HRV-based health monitoring and medical sensing systems.</abstract><cop>Basel</cop><pub>MDPI AG</pub><pmid>34067051</pmid><doi>10.3390/s21093235</doi><orcidid>https://orcid.org/0000-0002-2929-0561</orcidid><orcidid>https://orcid.org/0000-0002-2325-1043</orcidid><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1424-8220 |
ispartof | Sensors (Basel, Switzerland), 2021-05, Vol.21 (9), p.3235 |
issn | 1424-8220 1424-8220 |
language | eng |
recordid | cdi_doaj_primary_oai_doaj_org_article_9e8967469dd14332817de476a0403cbf |
source | Open Access: PubMed Central; Publicly Available Content Database |
subjects | Algorithms Arrhythmia autoencoder Cardiac arrhythmia Convulsions & seizures Electrocardiography Epilepsy extrasystole Failure Heart rate heart rate variability analysis machine learning Neural networks Noise reduction RRI data Seizures Sensors Sinuses Sleep Software |
title | Autoencoder-Based Extrasystole Detection and Modification of RRI Data for Precise Heart Rate Variability Analysis |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-08T20%3A26%3A58IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_doaj_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Autoencoder-Based%20Extrasystole%20Detection%20and%20Modification%20of%20RRI%20Data%20for%20Precise%20Heart%20Rate%20Variability%20Analysis&rft.jtitle=Sensors%20(Basel,%20Switzerland)&rft.au=Fujiwara,%20Koichi&rft.date=2021-05-07&rft.volume=21&rft.issue=9&rft.spage=3235&rft.pages=3235-&rft.issn=1424-8220&rft.eissn=1424-8220&rft_id=info:doi/10.3390/s21093235&rft_dat=%3Cproquest_doaj_%3E2530161027%3C/proquest_doaj_%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c512t-8da3f58b0f00e44643003894c2250479a4ad5a475efcf086a194956ba9dcfef73%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2530161027&rft_id=info:pmid/34067051&rfr_iscdi=true |