Loading…

Potential of Kinect-assessed stepping test for assessing fall risk in community-dwelling older women

•Movement pattern assessed during a 20-sec Stepping Test with eyes open may be an indicator of fall risk.•Motion analysis using an infrared depth sensor facilitates movement analysis and is easily employed anywhere.•Logistic analysis revealed an association between falls and total knee movement dist...

Full description

Saved in:
Bibliographic Details
Published in:Archives of gerontology and geriatrics plus 2024-12, Vol.1 (4), p.100077, Article 100077
Main Authors: Takeshima, Nobuo, Fujita, Eiji, Kohama, Takeshi, Osuka, Yosuke, Kojima, Narumi, Kusunoki, Masanobu, Brechue, William F., Sasai, Hiroyuki
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites cdi_FETCH-LOGICAL-c2067-68b1c47509366bfbfb3f9135edcef9f764d62901f643755c4810d2731b7e16c83
container_end_page
container_issue 4
container_start_page 100077
container_title Archives of gerontology and geriatrics plus
container_volume 1
creator Takeshima, Nobuo
Fujita, Eiji
Kohama, Takeshi
Osuka, Yosuke
Kojima, Narumi
Kusunoki, Masanobu
Brechue, William F.
Sasai, Hiroyuki
description •Movement pattern assessed during a 20-sec Stepping Test with eyes open may be an indicator of fall risk.•Motion analysis using an infrared depth sensor facilitates movement analysis and is easily employed anywhere.•Logistic analysis revealed an association between falls and total knee movement distance during a 20-sec Stepping Test. Previously, we have shown that movement path distance and displacement during a 20-sec stepping test (ST) discriminates between independent and dependent-living older adults. The present study aims to determine whether movement and displacement characteristics during ST are an indicator of risk of falling in independent-living, community-dwelling older women Independent-living older women recruited for this cross-sectional study were divided into a fall (F: n = 154) or no fall (NF: n = 847) history group. Each participant completed one trial of an eyes open, ST. ST outcome measures included head total movement distance (TMD), maximum movement displacement of the head (MMD), total knee movement distance (KMD), maximum height of the left and right knees (MKH), and step number (STEP) as determined with a KINECTTM infrared depth sensor. Ratio of KMD/TMD was calculated to index upper- body sway relative to the lower-body. Age, height, body mass, and BMI were not different between groups. KMD (F: median: 4.812 m, interquartile range (IQR): 3.720–7.718 m; NF: 5.309 m, 4.266–6.600 m), TMD / KMD (F: 0.145 m, 0.107–0.196 m; NF: 0.127 m, 0.100–0.170 m) and MKH (F: 0.073 m, 0.052–0.106 m, NF: 0.091 m, 0.060–0.135 m) were different between F and NF (Mann-Whitney, P < 0.05). Logistic regression revealed an association between falls and KMD (OR 1.232, 95 % CI 1.108–1.370). Characteristics of ST movement and displacement assessed with KinectTM provide useful indicators for fall risk assessment among independent-living, community-dwelling older women.
doi_str_mv 10.1016/j.aggp.2024.100077
format article
fullrecord <record><control><sourceid>elsevier_doaj_</sourceid><recordid>TN_cdi_doaj_primary_oai_doaj_org_article_a60b8c852d794965a761b7e1018f59a6</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S2950307824000742</els_id><doaj_id>oai_doaj_org_article_a60b8c852d794965a761b7e1018f59a6</doaj_id><sourcerecordid>S2950307824000742</sourcerecordid><originalsourceid>FETCH-LOGICAL-c2067-68b1c47509366bfbfb3f9135edcef9f764d62901f643755c4810d2731b7e16c83</originalsourceid><addsrcrecordid>eNp9kF1LwzAUhosoOOb-gFf5A535aJMWvJHhx3CgF3odsuRkpLbNSKpj_950FfFKEsjJe877kjxZdk3wkmDCb5ql2u32S4ppkQSMhTjLZrQucc6wqM7_1JfZIsYmjbB0E4zOMvPqB-gHp1rkLXp2PeghVzFC2gbFAfZ71-_QAHFA1gc0tUbJqrZFwcUP5Hqkfdd99m445uYAbTv2fWsgoIPvoL_KLtJ0hMXPOc_eH-7fVk_55uVxvbrb5JpiLnJebYkuRIlrxvnWpsVsTVgJRoOtreCF4bTGxPKCibLURUWwoYKRrQDCdcXm2XrKNV41ch9cp8JReuXkSfBhJ1UYnG5BKo63la5KakRd1LxUgp9iMKlsWSuesuiUpYOPMYD9zSNYjthlI0fscsQuJ-zJdDuZIP3yy0GQUTvoNRgXEtj0DPef_Rtr8Ys0</addsrcrecordid><sourcetype>Open Website</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Potential of Kinect-assessed stepping test for assessing fall risk in community-dwelling older women</title><source>ScienceDirect Journals</source><creator>Takeshima, Nobuo ; Fujita, Eiji ; Kohama, Takeshi ; Osuka, Yosuke ; Kojima, Narumi ; Kusunoki, Masanobu ; Brechue, William F. ; Sasai, Hiroyuki</creator><creatorcontrib>Takeshima, Nobuo ; Fujita, Eiji ; Kohama, Takeshi ; Osuka, Yosuke ; Kojima, Narumi ; Kusunoki, Masanobu ; Brechue, William F. ; Sasai, Hiroyuki</creatorcontrib><description>•Movement pattern assessed during a 20-sec Stepping Test with eyes open may be an indicator of fall risk.•Motion analysis using an infrared depth sensor facilitates movement analysis and is easily employed anywhere.•Logistic analysis revealed an association between falls and total knee movement distance during a 20-sec Stepping Test. Previously, we have shown that movement path distance and displacement during a 20-sec stepping test (ST) discriminates between independent and dependent-living older adults. The present study aims to determine whether movement and displacement characteristics during ST are an indicator of risk of falling in independent-living, community-dwelling older women Independent-living older women recruited for this cross-sectional study were divided into a fall (F: n = 154) or no fall (NF: n = 847) history group. Each participant completed one trial of an eyes open, ST. ST outcome measures included head total movement distance (TMD), maximum movement displacement of the head (MMD), total knee movement distance (KMD), maximum height of the left and right knees (MKH), and step number (STEP) as determined with a KINECTTM infrared depth sensor. Ratio of KMD/TMD was calculated to index upper- body sway relative to the lower-body. Age, height, body mass, and BMI were not different between groups. KMD (F: median: 4.812 m, interquartile range (IQR): 3.720–7.718 m; NF: 5.309 m, 4.266–6.600 m), TMD / KMD (F: 0.145 m, 0.107–0.196 m; NF: 0.127 m, 0.100–0.170 m) and MKH (F: 0.073 m, 0.052–0.106 m, NF: 0.091 m, 0.060–0.135 m) were different between F and NF (Mann-Whitney, P &lt; 0.05). Logistic regression revealed an association between falls and KMD (OR 1.232, 95 % CI 1.108–1.370). Characteristics of ST movement and displacement assessed with KinectTM provide useful indicators for fall risk assessment among independent-living, community-dwelling older women.</description><identifier>ISSN: 2950-3078</identifier><identifier>EISSN: 2950-3078</identifier><identifier>DOI: 10.1016/j.aggp.2024.100077</identifier><language>eng</language><publisher>Elsevier B.V</publisher><subject>Aging ; Fall history ; KinectTM infrared-depth sensor</subject><ispartof>Archives of gerontology and geriatrics plus, 2024-12, Vol.1 (4), p.100077, Article 100077</ispartof><rights>2024 The Author(s)</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c2067-68b1c47509366bfbfb3f9135edcef9f764d62901f643755c4810d2731b7e16c83</cites><orcidid>0000-0002-7307-7055</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/S2950307824000742$$EHTML$$P50$$Gelsevier$$Hfree_for_read</linktohtml><link.rule.ids>314,780,784,3547,27922,27923,45778</link.rule.ids></links><search><creatorcontrib>Takeshima, Nobuo</creatorcontrib><creatorcontrib>Fujita, Eiji</creatorcontrib><creatorcontrib>Kohama, Takeshi</creatorcontrib><creatorcontrib>Osuka, Yosuke</creatorcontrib><creatorcontrib>Kojima, Narumi</creatorcontrib><creatorcontrib>Kusunoki, Masanobu</creatorcontrib><creatorcontrib>Brechue, William F.</creatorcontrib><creatorcontrib>Sasai, Hiroyuki</creatorcontrib><title>Potential of Kinect-assessed stepping test for assessing fall risk in community-dwelling older women</title><title>Archives of gerontology and geriatrics plus</title><description>•Movement pattern assessed during a 20-sec Stepping Test with eyes open may be an indicator of fall risk.•Motion analysis using an infrared depth sensor facilitates movement analysis and is easily employed anywhere.•Logistic analysis revealed an association between falls and total knee movement distance during a 20-sec Stepping Test. Previously, we have shown that movement path distance and displacement during a 20-sec stepping test (ST) discriminates between independent and dependent-living older adults. The present study aims to determine whether movement and displacement characteristics during ST are an indicator of risk of falling in independent-living, community-dwelling older women Independent-living older women recruited for this cross-sectional study were divided into a fall (F: n = 154) or no fall (NF: n = 847) history group. Each participant completed one trial of an eyes open, ST. ST outcome measures included head total movement distance (TMD), maximum movement displacement of the head (MMD), total knee movement distance (KMD), maximum height of the left and right knees (MKH), and step number (STEP) as determined with a KINECTTM infrared depth sensor. Ratio of KMD/TMD was calculated to index upper- body sway relative to the lower-body. Age, height, body mass, and BMI were not different between groups. KMD (F: median: 4.812 m, interquartile range (IQR): 3.720–7.718 m; NF: 5.309 m, 4.266–6.600 m), TMD / KMD (F: 0.145 m, 0.107–0.196 m; NF: 0.127 m, 0.100–0.170 m) and MKH (F: 0.073 m, 0.052–0.106 m, NF: 0.091 m, 0.060–0.135 m) were different between F and NF (Mann-Whitney, P &lt; 0.05). Logistic regression revealed an association between falls and KMD (OR 1.232, 95 % CI 1.108–1.370). Characteristics of ST movement and displacement assessed with KinectTM provide useful indicators for fall risk assessment among independent-living, community-dwelling older women.</description><subject>Aging</subject><subject>Fall history</subject><subject>KinectTM infrared-depth sensor</subject><issn>2950-3078</issn><issn>2950-3078</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><sourceid>DOA</sourceid><recordid>eNp9kF1LwzAUhosoOOb-gFf5A535aJMWvJHhx3CgF3odsuRkpLbNSKpj_950FfFKEsjJe877kjxZdk3wkmDCb5ql2u32S4ppkQSMhTjLZrQucc6wqM7_1JfZIsYmjbB0E4zOMvPqB-gHp1rkLXp2PeghVzFC2gbFAfZ71-_QAHFA1gc0tUbJqrZFwcUP5Hqkfdd99m445uYAbTv2fWsgoIPvoL_KLtJ0hMXPOc_eH-7fVk_55uVxvbrb5JpiLnJebYkuRIlrxvnWpsVsTVgJRoOtreCF4bTGxPKCibLURUWwoYKRrQDCdcXm2XrKNV41ch9cp8JReuXkSfBhJ1UYnG5BKo63la5KakRd1LxUgp9iMKlsWSuesuiUpYOPMYD9zSNYjthlI0fscsQuJ-zJdDuZIP3yy0GQUTvoNRgXEtj0DPef_Rtr8Ys0</recordid><startdate>202412</startdate><enddate>202412</enddate><creator>Takeshima, Nobuo</creator><creator>Fujita, Eiji</creator><creator>Kohama, Takeshi</creator><creator>Osuka, Yosuke</creator><creator>Kojima, Narumi</creator><creator>Kusunoki, Masanobu</creator><creator>Brechue, William F.</creator><creator>Sasai, Hiroyuki</creator><general>Elsevier B.V</general><general>Elsevier</general><scope>6I.</scope><scope>AAFTH</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>DOA</scope><orcidid>https://orcid.org/0000-0002-7307-7055</orcidid></search><sort><creationdate>202412</creationdate><title>Potential of Kinect-assessed stepping test for assessing fall risk in community-dwelling older women</title><author>Takeshima, Nobuo ; Fujita, Eiji ; Kohama, Takeshi ; Osuka, Yosuke ; Kojima, Narumi ; Kusunoki, Masanobu ; Brechue, William F. ; Sasai, Hiroyuki</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c2067-68b1c47509366bfbfb3f9135edcef9f764d62901f643755c4810d2731b7e16c83</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><topic>Aging</topic><topic>Fall history</topic><topic>KinectTM infrared-depth sensor</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Takeshima, Nobuo</creatorcontrib><creatorcontrib>Fujita, Eiji</creatorcontrib><creatorcontrib>Kohama, Takeshi</creatorcontrib><creatorcontrib>Osuka, Yosuke</creatorcontrib><creatorcontrib>Kojima, Narumi</creatorcontrib><creatorcontrib>Kusunoki, Masanobu</creatorcontrib><creatorcontrib>Brechue, William F.</creatorcontrib><creatorcontrib>Sasai, Hiroyuki</creatorcontrib><collection>ScienceDirect Open Access Titles</collection><collection>Elsevier:ScienceDirect:Open Access</collection><collection>CrossRef</collection><collection>DOAJ Directory of Open Access Journals</collection><jtitle>Archives of gerontology and geriatrics plus</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Takeshima, Nobuo</au><au>Fujita, Eiji</au><au>Kohama, Takeshi</au><au>Osuka, Yosuke</au><au>Kojima, Narumi</au><au>Kusunoki, Masanobu</au><au>Brechue, William F.</au><au>Sasai, Hiroyuki</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Potential of Kinect-assessed stepping test for assessing fall risk in community-dwelling older women</atitle><jtitle>Archives of gerontology and geriatrics plus</jtitle><date>2024-12</date><risdate>2024</risdate><volume>1</volume><issue>4</issue><spage>100077</spage><pages>100077-</pages><artnum>100077</artnum><issn>2950-3078</issn><eissn>2950-3078</eissn><abstract>•Movement pattern assessed during a 20-sec Stepping Test with eyes open may be an indicator of fall risk.•Motion analysis using an infrared depth sensor facilitates movement analysis and is easily employed anywhere.•Logistic analysis revealed an association between falls and total knee movement distance during a 20-sec Stepping Test. Previously, we have shown that movement path distance and displacement during a 20-sec stepping test (ST) discriminates between independent and dependent-living older adults. The present study aims to determine whether movement and displacement characteristics during ST are an indicator of risk of falling in independent-living, community-dwelling older women Independent-living older women recruited for this cross-sectional study were divided into a fall (F: n = 154) or no fall (NF: n = 847) history group. Each participant completed one trial of an eyes open, ST. ST outcome measures included head total movement distance (TMD), maximum movement displacement of the head (MMD), total knee movement distance (KMD), maximum height of the left and right knees (MKH), and step number (STEP) as determined with a KINECTTM infrared depth sensor. Ratio of KMD/TMD was calculated to index upper- body sway relative to the lower-body. Age, height, body mass, and BMI were not different between groups. KMD (F: median: 4.812 m, interquartile range (IQR): 3.720–7.718 m; NF: 5.309 m, 4.266–6.600 m), TMD / KMD (F: 0.145 m, 0.107–0.196 m; NF: 0.127 m, 0.100–0.170 m) and MKH (F: 0.073 m, 0.052–0.106 m, NF: 0.091 m, 0.060–0.135 m) were different between F and NF (Mann-Whitney, P &lt; 0.05). Logistic regression revealed an association between falls and KMD (OR 1.232, 95 % CI 1.108–1.370). Characteristics of ST movement and displacement assessed with KinectTM provide useful indicators for fall risk assessment among independent-living, community-dwelling older women.</abstract><pub>Elsevier B.V</pub><doi>10.1016/j.aggp.2024.100077</doi><orcidid>https://orcid.org/0000-0002-7307-7055</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 2950-3078
ispartof Archives of gerontology and geriatrics plus, 2024-12, Vol.1 (4), p.100077, Article 100077
issn 2950-3078
2950-3078
language eng
recordid cdi_doaj_primary_oai_doaj_org_article_a60b8c852d794965a761b7e1018f59a6
source ScienceDirect Journals
subjects Aging
Fall history
KinectTM infrared-depth sensor
title Potential of Kinect-assessed stepping test for assessing fall risk in community-dwelling older women
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-14T12%3A22%3A23IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-elsevier_doaj_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Potential%20of%20Kinect-assessed%20stepping%20test%20for%20assessing%20fall%20risk%20in%20community-dwelling%20older%20women&rft.jtitle=Archives%20of%20gerontology%20and%20geriatrics%20plus&rft.au=Takeshima,%20Nobuo&rft.date=2024-12&rft.volume=1&rft.issue=4&rft.spage=100077&rft.pages=100077-&rft.artnum=100077&rft.issn=2950-3078&rft.eissn=2950-3078&rft_id=info:doi/10.1016/j.aggp.2024.100077&rft_dat=%3Celsevier_doaj_%3ES2950307824000742%3C/elsevier_doaj_%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c2067-68b1c47509366bfbfb3f9135edcef9f764d62901f643755c4810d2731b7e16c83%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true