Loading…

Study on prevention and control measures of sandstone geothermal reinjection plugging

In the process of geothermal tailwater reinjection of sandstone, the problem of plugging has been seriously restricting the continuous development of geothermal reinjection for many years, and the problems of plugging are complex and changeable. The plugging in the process of reinjection can be divi...

Full description

Saved in:
Bibliographic Details
Published in:Water science and technology 2023-03, Vol.87 (6), p.1571-1581
Main Authors: Wang, Xiangtao, Wang, Jianzhong, Yan, Guangyu, Liu, Xiaozhe, Huang, Yue, Tian, Suo, Xu, Qingfa
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c423t-f5c8b88b39acfad7c3ab62281fc413726f8e0b5c692a7af1b327a1304a97fa153
cites cdi_FETCH-LOGICAL-c423t-f5c8b88b39acfad7c3ab62281fc413726f8e0b5c692a7af1b327a1304a97fa153
container_end_page 1581
container_issue 6
container_start_page 1571
container_title Water science and technology
container_volume 87
creator Wang, Xiangtao
Wang, Jianzhong
Yan, Guangyu
Liu, Xiaozhe
Huang, Yue
Tian, Suo
Xu, Qingfa
description In the process of geothermal tailwater reinjection of sandstone, the problem of plugging has been seriously restricting the continuous development of geothermal reinjection for many years, and the problems of plugging are complex and changeable. The plugging in the process of reinjection can be divided into physical plugging, chemical plugging, microbial plugging and gas plugging. Given these four types of blocking, according to the mechanism characteristics of the blocking caused by them, this paper puts forward corresponding blocking prevention measures and solves the current blocking problems by filtering, adding a scale inhibitor, intermittent reinjection, adding chlorine dioxide and regular lifting. In addition, the existing reinjection process and the equipment flow are relatively simple and cannot achieve the goal of efficient reinjection. Therefore, a complete set of reinjection processes is designed to ensure the efficient reinjection of sandstone geothermal tailwater.
doi_str_mv 10.2166/wst.2023.078
format article
fullrecord <record><control><sourceid>proquest_doaj_</sourceid><recordid>TN_cdi_doaj_primary_oai_doaj_org_article_a7608c18c1cf46d5a89cc46006e0d682</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><doaj_id>oai_doaj_org_article_a7608c18c1cf46d5a89cc46006e0d682</doaj_id><sourcerecordid>2793990330</sourcerecordid><originalsourceid>FETCH-LOGICAL-c423t-f5c8b88b39acfad7c3ab62281fc413726f8e0b5c692a7af1b327a1304a97fa153</originalsourceid><addsrcrecordid>eNpdkU1v1DAQhi0EotvCjTOKxIVDs4ztxB9HVPFRqRIH6NmaOHbIKrEX2wH13-N2Sw9IlsbyPPNqrIeQNxT2jArx4U8uewaM70GqZ2RHtRatlpw9JztgkreUMX5GznM-AIDkHbwkZ1wC0Dq8I7ffyzbeNTE0x-R-u1DmesUwNjaGkuLSrA7zllxuom9ybeQSg2smF8tPl1ZcmuTmcHD2YfC4bNM0h-kVeeFxye71Y70gt58__bj62t58-3J99fGmtR3jpfW9VYNSA9doPY7SchwEY4p621EumfDKwdBboRlK9HTgTCLl0KGWHmnPL8j1KXeMeDDHNK-Y7kzE2Tw8xDQZTGW2izMoBShL67G-E2OPSlvbCQDhYBSK1az3p6xjir82l4tZ52zdsmBwccuGSc21Bs6hou_-Qw9xS6H-1DClqegV60SlLk-UTTHn5PzTghTMvTpT1Zl7daaqq_jbx9BtWN34BP9zxf8CMyGUhw</addsrcrecordid><sourcetype>Open Website</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2891658246</pqid></control><display><type>article</type><title>Study on prevention and control measures of sandstone geothermal reinjection plugging</title><source>Alma/SFX Local Collection</source><creator>Wang, Xiangtao ; Wang, Jianzhong ; Yan, Guangyu ; Liu, Xiaozhe ; Huang, Yue ; Tian, Suo ; Xu, Qingfa</creator><creatorcontrib>Wang, Xiangtao ; Wang, Jianzhong ; Yan, Guangyu ; Liu, Xiaozhe ; Huang, Yue ; Tian, Suo ; Xu, Qingfa</creatorcontrib><description>In the process of geothermal tailwater reinjection of sandstone, the problem of plugging has been seriously restricting the continuous development of geothermal reinjection for many years, and the problems of plugging are complex and changeable. The plugging in the process of reinjection can be divided into physical plugging, chemical plugging, microbial plugging and gas plugging. Given these four types of blocking, according to the mechanism characteristics of the blocking caused by them, this paper puts forward corresponding blocking prevention measures and solves the current blocking problems by filtering, adding a scale inhibitor, intermittent reinjection, adding chlorine dioxide and regular lifting. In addition, the existing reinjection process and the equipment flow are relatively simple and cannot achieve the goal of efficient reinjection. Therefore, a complete set of reinjection processes is designed to ensure the efficient reinjection of sandstone geothermal tailwater.</description><identifier>ISSN: 0273-1223</identifier><identifier>EISSN: 1996-9732</identifier><identifier>DOI: 10.2166/wst.2023.078</identifier><identifier>PMID: 37001166</identifier><language>eng</language><publisher>England: IWA Publishing</publisher><subject>blockage ; Chlorine ; Chlorine dioxide ; Efficiency ; Experiments ; Microorganisms ; Particle size ; Plugging ; Prevention ; prevention and control measures ; Reinjection ; Sandstone ; sandstone geothermal ; Sedimentary rocks ; simulation experiment ; Tailwater ; tailwater reinjection ; Zeolites</subject><ispartof>Water science and technology, 2023-03, Vol.87 (6), p.1571-1581</ispartof><rights>Copyright IWA Publishing Mar 2023</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c423t-f5c8b88b39acfad7c3ab62281fc413726f8e0b5c692a7af1b327a1304a97fa153</citedby><cites>FETCH-LOGICAL-c423t-f5c8b88b39acfad7c3ab62281fc413726f8e0b5c692a7af1b327a1304a97fa153</cites><orcidid>0000-0002-0474-8732</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27923,27924</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/37001166$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Wang, Xiangtao</creatorcontrib><creatorcontrib>Wang, Jianzhong</creatorcontrib><creatorcontrib>Yan, Guangyu</creatorcontrib><creatorcontrib>Liu, Xiaozhe</creatorcontrib><creatorcontrib>Huang, Yue</creatorcontrib><creatorcontrib>Tian, Suo</creatorcontrib><creatorcontrib>Xu, Qingfa</creatorcontrib><title>Study on prevention and control measures of sandstone geothermal reinjection plugging</title><title>Water science and technology</title><addtitle>Water Sci Technol</addtitle><description>In the process of geothermal tailwater reinjection of sandstone, the problem of plugging has been seriously restricting the continuous development of geothermal reinjection for many years, and the problems of plugging are complex and changeable. The plugging in the process of reinjection can be divided into physical plugging, chemical plugging, microbial plugging and gas plugging. Given these four types of blocking, according to the mechanism characteristics of the blocking caused by them, this paper puts forward corresponding blocking prevention measures and solves the current blocking problems by filtering, adding a scale inhibitor, intermittent reinjection, adding chlorine dioxide and regular lifting. In addition, the existing reinjection process and the equipment flow are relatively simple and cannot achieve the goal of efficient reinjection. Therefore, a complete set of reinjection processes is designed to ensure the efficient reinjection of sandstone geothermal tailwater.</description><subject>blockage</subject><subject>Chlorine</subject><subject>Chlorine dioxide</subject><subject>Efficiency</subject><subject>Experiments</subject><subject>Microorganisms</subject><subject>Particle size</subject><subject>Plugging</subject><subject>Prevention</subject><subject>prevention and control measures</subject><subject>Reinjection</subject><subject>Sandstone</subject><subject>sandstone geothermal</subject><subject>Sedimentary rocks</subject><subject>simulation experiment</subject><subject>Tailwater</subject><subject>tailwater reinjection</subject><subject>Zeolites</subject><issn>0273-1223</issn><issn>1996-9732</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2023</creationdate><recordtype>article</recordtype><sourceid>DOA</sourceid><recordid>eNpdkU1v1DAQhi0EotvCjTOKxIVDs4ztxB9HVPFRqRIH6NmaOHbIKrEX2wH13-N2Sw9IlsbyPPNqrIeQNxT2jArx4U8uewaM70GqZ2RHtRatlpw9JztgkreUMX5GznM-AIDkHbwkZ1wC0Dq8I7ffyzbeNTE0x-R-u1DmesUwNjaGkuLSrA7zllxuom9ybeQSg2smF8tPl1ZcmuTmcHD2YfC4bNM0h-kVeeFxye71Y70gt58__bj62t58-3J99fGmtR3jpfW9VYNSA9doPY7SchwEY4p621EumfDKwdBboRlK9HTgTCLl0KGWHmnPL8j1KXeMeDDHNK-Y7kzE2Tw8xDQZTGW2izMoBShL67G-E2OPSlvbCQDhYBSK1az3p6xjir82l4tZ52zdsmBwccuGSc21Bs6hou_-Qw9xS6H-1DClqegV60SlLk-UTTHn5PzTghTMvTpT1Zl7daaqq_jbx9BtWN34BP9zxf8CMyGUhw</recordid><startdate>202303</startdate><enddate>202303</enddate><creator>Wang, Xiangtao</creator><creator>Wang, Jianzhong</creator><creator>Yan, Guangyu</creator><creator>Liu, Xiaozhe</creator><creator>Huang, Yue</creator><creator>Tian, Suo</creator><creator>Xu, Qingfa</creator><general>IWA Publishing</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>3V.</scope><scope>7QH</scope><scope>7UA</scope><scope>7X7</scope><scope>7XB</scope><scope>88E</scope><scope>8FE</scope><scope>8FG</scope><scope>8FI</scope><scope>8FJ</scope><scope>8FK</scope><scope>ABJCF</scope><scope>ABUWG</scope><scope>AEUYN</scope><scope>AFKRA</scope><scope>BENPR</scope><scope>BGLVJ</scope><scope>BHPHI</scope><scope>BKSAR</scope><scope>C1K</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>F1W</scope><scope>FYUFA</scope><scope>GHDGH</scope><scope>H96</scope><scope>H97</scope><scope>HCIFZ</scope><scope>K9.</scope><scope>L.G</scope><scope>L6V</scope><scope>M0S</scope><scope>M1P</scope><scope>M7S</scope><scope>PCBAR</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PTHSS</scope><scope>7X8</scope><scope>DOA</scope><orcidid>https://orcid.org/0000-0002-0474-8732</orcidid></search><sort><creationdate>202303</creationdate><title>Study on prevention and control measures of sandstone geothermal reinjection plugging</title><author>Wang, Xiangtao ; Wang, Jianzhong ; Yan, Guangyu ; Liu, Xiaozhe ; Huang, Yue ; Tian, Suo ; Xu, Qingfa</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c423t-f5c8b88b39acfad7c3ab62281fc413726f8e0b5c692a7af1b327a1304a97fa153</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2023</creationdate><topic>blockage</topic><topic>Chlorine</topic><topic>Chlorine dioxide</topic><topic>Efficiency</topic><topic>Experiments</topic><topic>Microorganisms</topic><topic>Particle size</topic><topic>Plugging</topic><topic>Prevention</topic><topic>prevention and control measures</topic><topic>Reinjection</topic><topic>Sandstone</topic><topic>sandstone geothermal</topic><topic>Sedimentary rocks</topic><topic>simulation experiment</topic><topic>Tailwater</topic><topic>tailwater reinjection</topic><topic>Zeolites</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Wang, Xiangtao</creatorcontrib><creatorcontrib>Wang, Jianzhong</creatorcontrib><creatorcontrib>Yan, Guangyu</creatorcontrib><creatorcontrib>Liu, Xiaozhe</creatorcontrib><creatorcontrib>Huang, Yue</creatorcontrib><creatorcontrib>Tian, Suo</creatorcontrib><creatorcontrib>Xu, Qingfa</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>ProQuest Central (Corporate)</collection><collection>Aqualine</collection><collection>Water Resources Abstracts</collection><collection>ProQuest_Health &amp; Medical Collection</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>Medical Database (Alumni Edition)</collection><collection>ProQuest SciTech Collection</collection><collection>ProQuest Technology Collection</collection><collection>Hospital Premium Collection</collection><collection>Hospital Premium Collection (Alumni Edition)</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>Materials Science &amp; Engineering Collection</collection><collection>ProQuest Central (Alumni)</collection><collection>ProQuest One Sustainability</collection><collection>ProQuest Central</collection><collection>AUTh Library subscriptions: ProQuest Central</collection><collection>Technology Collection</collection><collection>ProQuest Natural Science Collection</collection><collection>Earth, Atmospheric &amp; Aquatic Science Collection</collection><collection>Environmental Sciences and Pollution Management</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central</collection><collection>ASFA: Aquatic Sciences and Fisheries Abstracts</collection><collection>Health Research Premium Collection</collection><collection>Health Research Premium Collection (Alumni)</collection><collection>Aquatic Science &amp; Fisheries Abstracts (ASFA) 2: Ocean Technology, Policy &amp; Non-Living Resources</collection><collection>Aquatic Science &amp; Fisheries Abstracts (ASFA) 3: Aquatic Pollution &amp; Environmental Quality</collection><collection>SciTech Premium Collection</collection><collection>ProQuest Health &amp; Medical Complete (Alumni)</collection><collection>Aquatic Science &amp; Fisheries Abstracts (ASFA) Professional</collection><collection>ProQuest Engineering Collection</collection><collection>Health &amp; Medical Collection (Alumni Edition)</collection><collection>PML(ProQuest Medical Library)</collection><collection>Engineering Database</collection><collection>Earth, Atmospheric &amp; Aquatic Science Database</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>Engineering Collection</collection><collection>MEDLINE - Academic</collection><collection>DOAJ Directory of Open Access Journals</collection><jtitle>Water science and technology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Wang, Xiangtao</au><au>Wang, Jianzhong</au><au>Yan, Guangyu</au><au>Liu, Xiaozhe</au><au>Huang, Yue</au><au>Tian, Suo</au><au>Xu, Qingfa</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Study on prevention and control measures of sandstone geothermal reinjection plugging</atitle><jtitle>Water science and technology</jtitle><addtitle>Water Sci Technol</addtitle><date>2023-03</date><risdate>2023</risdate><volume>87</volume><issue>6</issue><spage>1571</spage><epage>1581</epage><pages>1571-1581</pages><issn>0273-1223</issn><eissn>1996-9732</eissn><abstract>In the process of geothermal tailwater reinjection of sandstone, the problem of plugging has been seriously restricting the continuous development of geothermal reinjection for many years, and the problems of plugging are complex and changeable. The plugging in the process of reinjection can be divided into physical plugging, chemical plugging, microbial plugging and gas plugging. Given these four types of blocking, according to the mechanism characteristics of the blocking caused by them, this paper puts forward corresponding blocking prevention measures and solves the current blocking problems by filtering, adding a scale inhibitor, intermittent reinjection, adding chlorine dioxide and regular lifting. In addition, the existing reinjection process and the equipment flow are relatively simple and cannot achieve the goal of efficient reinjection. Therefore, a complete set of reinjection processes is designed to ensure the efficient reinjection of sandstone geothermal tailwater.</abstract><cop>England</cop><pub>IWA Publishing</pub><pmid>37001166</pmid><doi>10.2166/wst.2023.078</doi><tpages>11</tpages><orcidid>https://orcid.org/0000-0002-0474-8732</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0273-1223
ispartof Water science and technology, 2023-03, Vol.87 (6), p.1571-1581
issn 0273-1223
1996-9732
language eng
recordid cdi_doaj_primary_oai_doaj_org_article_a7608c18c1cf46d5a89cc46006e0d682
source Alma/SFX Local Collection
subjects blockage
Chlorine
Chlorine dioxide
Efficiency
Experiments
Microorganisms
Particle size
Plugging
Prevention
prevention and control measures
Reinjection
Sandstone
sandstone geothermal
Sedimentary rocks
simulation experiment
Tailwater
tailwater reinjection
Zeolites
title Study on prevention and control measures of sandstone geothermal reinjection plugging
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-13T06%3A52%3A02IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_doaj_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Study%20on%20prevention%20and%20control%20measures%20of%20sandstone%20geothermal%20reinjection%20plugging&rft.jtitle=Water%20science%20and%20technology&rft.au=Wang,%20Xiangtao&rft.date=2023-03&rft.volume=87&rft.issue=6&rft.spage=1571&rft.epage=1581&rft.pages=1571-1581&rft.issn=0273-1223&rft.eissn=1996-9732&rft_id=info:doi/10.2166/wst.2023.078&rft_dat=%3Cproquest_doaj_%3E2793990330%3C/proquest_doaj_%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c423t-f5c8b88b39acfad7c3ab62281fc413726f8e0b5c692a7af1b327a1304a97fa153%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2891658246&rft_id=info:pmid/37001166&rfr_iscdi=true