Loading…
The delayed effects of flooding a residential building – case study
The work describes the case of a single-family residential building, which suffered a breakdown due to flooding. Flooded water in the nearby watercourse, did not reach the building directly, but in its vicinity, but raised to a very high level the local groundwater table, which reached locally, even...
Saved in:
Published in: | MATEC web of conferences 2019, Vol.284, p.3009 |
---|---|
Main Author: | |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | |
---|---|
cites | cdi_FETCH-LOGICAL-c1899-e12b84f7927199ac29a0171eb8573c685526cef9afd95908e161d252b5d65d013 |
container_end_page | |
container_issue | |
container_start_page | 3009 |
container_title | MATEC web of conferences |
container_volume | 284 |
creator | Straż, Grzegorz |
description | The work describes the case of a single-family residential building, which suffered a breakdown due to flooding. Flooded water in the nearby watercourse, did not reach the building directly, but in its vicinity, but raised to a very high level the local groundwater table, which reached locally, even above ground level. This condition was maintained over a longer period of time, causing the soil moisture to rise, and thus its geotechnical parameters deteriorated. The consequence of this, the building underwent an uncontrolled and uneven settlement, which was accompanied by the formation of cracks on the walls. The effects of failure were presented and an attempt was made to identify possible causes of failure. Own study of the substrate was carried out in "in situ" conditions and verification of laboratory tests, and their results are presented on relevant charts and tables. |
doi_str_mv | 10.1051/matecconf/201928403009 |
format | article |
fullrecord | <record><control><sourceid>proquest_doaj_</sourceid><recordid>TN_cdi_doaj_primary_oai_doaj_org_article_a800323a37fe4c2488b3148084ddcade</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><doaj_id>oai_doaj_org_article_a800323a37fe4c2488b3148084ddcade</doaj_id><sourcerecordid>2277007817</sourcerecordid><originalsourceid>FETCH-LOGICAL-c1899-e12b84f7927199ac29a0171eb8573c685526cef9afd95908e161d252b5d65d013</originalsourceid><addsrcrecordid>eNpNkcFKAzEURQdRsNT-ggRcj74kM5NkKaVqoeCmgruQSV7qlOmkJtNFd_6Df-iXOLZSunqXy-W8CzfLbincUyjpw8b0aG3o_AMDqpgsgAOoi2zEWEVzxqv3yzN9nU1SWgMA5UqAEqNstvxA4rA1e3QEvUfbJxI88W0IrulWxJCIqXHY9Y1pSb1r2oP98_VNrElIUr9z-5vsyps24eT_jrO3p9ly-pIvXp_n08dFbqlUKkfKall4oZigShnLlAEqKNayFNxWsixZZdEr450qFUikFXWsZHXpqtINpcfZ_Mh1waz1NjYbE_c6mEYfjBBX2sS-sS1qIwE444YLj4VlhZQ1p4UEWThnjcOBdXdkbWP43GHq9TrsYjfU14wJASAkFUOqOqZsDClF9KevFPTfAvq0gD5fgP8CA1l6nA</addsrcrecordid><sourcetype>Open Website</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2277007817</pqid></control><display><type>article</type><title>The delayed effects of flooding a residential building – case study</title><source>Publicly Available Content Database</source><creator>Straż, Grzegorz</creator><contributor>Kaszynska, M.</contributor><creatorcontrib>Straż, Grzegorz ; Kaszynska, M.</creatorcontrib><description>The work describes the case of a single-family residential building, which suffered a breakdown due to flooding. Flooded water in the nearby watercourse, did not reach the building directly, but in its vicinity, but raised to a very high level the local groundwater table, which reached locally, even above ground level. This condition was maintained over a longer period of time, causing the soil moisture to rise, and thus its geotechnical parameters deteriorated. The consequence of this, the building underwent an uncontrolled and uneven settlement, which was accompanied by the formation of cracks on the walls. The effects of failure were presented and an attempt was made to identify possible causes of failure. Own study of the substrate was carried out in "in situ" conditions and verification of laboratory tests, and their results are presented on relevant charts and tables.</description><identifier>ISSN: 2261-236X</identifier><identifier>ISSN: 2274-7214</identifier><identifier>EISSN: 2261-236X</identifier><identifier>DOI: 10.1051/matecconf/201928403009</identifier><language>eng</language><publisher>Les Ulis: EDP Sciences</publisher><subject>Cracks ; Flooding ; Floods ; Ground level ; Groundwater levels ; Laboratory tests ; Residential buildings ; Soil moisture ; Substrates ; Water table</subject><ispartof>MATEC web of conferences, 2019, Vol.284, p.3009</ispartof><rights>2019. This work is licensed under http://creativecommons.org/licenses/by/4.0/ (the “License”). Notwithstanding the ProQuest Terms and conditions, you may use this content in accordance with the terms of the License.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c1899-e12b84f7927199ac29a0171eb8573c685526cef9afd95908e161d252b5d65d013</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.proquest.com/docview/2277007817?pq-origsite=primo$$EHTML$$P50$$Gproquest$$Hfree_for_read</linktohtml><link.rule.ids>309,310,314,776,780,785,786,4010,23909,23910,25118,25731,27900,27901,27902,36989,44566</link.rule.ids></links><search><contributor>Kaszynska, M.</contributor><creatorcontrib>Straż, Grzegorz</creatorcontrib><title>The delayed effects of flooding a residential building – case study</title><title>MATEC web of conferences</title><description>The work describes the case of a single-family residential building, which suffered a breakdown due to flooding. Flooded water in the nearby watercourse, did not reach the building directly, but in its vicinity, but raised to a very high level the local groundwater table, which reached locally, even above ground level. This condition was maintained over a longer period of time, causing the soil moisture to rise, and thus its geotechnical parameters deteriorated. The consequence of this, the building underwent an uncontrolled and uneven settlement, which was accompanied by the formation of cracks on the walls. The effects of failure were presented and an attempt was made to identify possible causes of failure. Own study of the substrate was carried out in "in situ" conditions and verification of laboratory tests, and their results are presented on relevant charts and tables.</description><subject>Cracks</subject><subject>Flooding</subject><subject>Floods</subject><subject>Ground level</subject><subject>Groundwater levels</subject><subject>Laboratory tests</subject><subject>Residential buildings</subject><subject>Soil moisture</subject><subject>Substrates</subject><subject>Water table</subject><issn>2261-236X</issn><issn>2274-7214</issn><issn>2261-236X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2019</creationdate><recordtype>article</recordtype><sourceid>PIMPY</sourceid><sourceid>DOA</sourceid><recordid>eNpNkcFKAzEURQdRsNT-ggRcj74kM5NkKaVqoeCmgruQSV7qlOmkJtNFd_6Df-iXOLZSunqXy-W8CzfLbincUyjpw8b0aG3o_AMDqpgsgAOoi2zEWEVzxqv3yzN9nU1SWgMA5UqAEqNstvxA4rA1e3QEvUfbJxI88W0IrulWxJCIqXHY9Y1pSb1r2oP98_VNrElIUr9z-5vsyps24eT_jrO3p9ly-pIvXp_n08dFbqlUKkfKall4oZigShnLlAEqKNayFNxWsixZZdEr450qFUikFXWsZHXpqtINpcfZ_Mh1waz1NjYbE_c6mEYfjBBX2sS-sS1qIwE444YLj4VlhZQ1p4UEWThnjcOBdXdkbWP43GHq9TrsYjfU14wJASAkFUOqOqZsDClF9KevFPTfAvq0gD5fgP8CA1l6nA</recordid><startdate>2019</startdate><enddate>2019</enddate><creator>Straż, Grzegorz</creator><general>EDP Sciences</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7SP</scope><scope>7SR</scope><scope>7TB</scope><scope>8BQ</scope><scope>8FD</scope><scope>8FE</scope><scope>8FG</scope><scope>ABJCF</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>BGLVJ</scope><scope>CCPQU</scope><scope>D1I</scope><scope>DWQXO</scope><scope>FR3</scope><scope>HCIFZ</scope><scope>JG9</scope><scope>KB.</scope><scope>KR7</scope><scope>L6V</scope><scope>L7M</scope><scope>M7S</scope><scope>PDBOC</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>PTHSS</scope><scope>DOA</scope></search><sort><creationdate>2019</creationdate><title>The delayed effects of flooding a residential building – case study</title><author>Straż, Grzegorz</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c1899-e12b84f7927199ac29a0171eb8573c685526cef9afd95908e161d252b5d65d013</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2019</creationdate><topic>Cracks</topic><topic>Flooding</topic><topic>Floods</topic><topic>Ground level</topic><topic>Groundwater levels</topic><topic>Laboratory tests</topic><topic>Residential buildings</topic><topic>Soil moisture</topic><topic>Substrates</topic><topic>Water table</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Straż, Grzegorz</creatorcontrib><collection>CrossRef</collection><collection>Electronics & Communications Abstracts</collection><collection>Engineered Materials Abstracts</collection><collection>Mechanical & Transportation Engineering Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>ProQuest SciTech Collection</collection><collection>ProQuest Technology Collection</collection><collection>Materials Science & Engineering Collection</collection><collection>ProQuest Central (Alumni)</collection><collection>ProQuest Central</collection><collection>ProQuest Central Essentials</collection><collection>ProQuest Central</collection><collection>Technology Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Materials Science Collection</collection><collection>ProQuest Central Korea</collection><collection>Engineering Research Database</collection><collection>SciTech Premium Collection</collection><collection>Materials Research Database</collection><collection>Materials Science Database</collection><collection>Civil Engineering Abstracts</collection><collection>ProQuest Engineering Collection</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>Engineering Database</collection><collection>Materials Science Collection</collection><collection>Publicly Available Content Database</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>Engineering Collection</collection><collection>DOAJ Directory of Open Access Journals</collection><jtitle>MATEC web of conferences</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Straż, Grzegorz</au><au>Kaszynska, M.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>The delayed effects of flooding a residential building – case study</atitle><jtitle>MATEC web of conferences</jtitle><date>2019</date><risdate>2019</risdate><volume>284</volume><spage>3009</spage><pages>3009-</pages><issn>2261-236X</issn><issn>2274-7214</issn><eissn>2261-236X</eissn><abstract>The work describes the case of a single-family residential building, which suffered a breakdown due to flooding. Flooded water in the nearby watercourse, did not reach the building directly, but in its vicinity, but raised to a very high level the local groundwater table, which reached locally, even above ground level. This condition was maintained over a longer period of time, causing the soil moisture to rise, and thus its geotechnical parameters deteriorated. The consequence of this, the building underwent an uncontrolled and uneven settlement, which was accompanied by the formation of cracks on the walls. The effects of failure were presented and an attempt was made to identify possible causes of failure. Own study of the substrate was carried out in "in situ" conditions and verification of laboratory tests, and their results are presented on relevant charts and tables.</abstract><cop>Les Ulis</cop><pub>EDP Sciences</pub><doi>10.1051/matecconf/201928403009</doi><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 2261-236X |
ispartof | MATEC web of conferences, 2019, Vol.284, p.3009 |
issn | 2261-236X 2274-7214 2261-236X |
language | eng |
recordid | cdi_doaj_primary_oai_doaj_org_article_a800323a37fe4c2488b3148084ddcade |
source | Publicly Available Content Database |
subjects | Cracks Flooding Floods Ground level Groundwater levels Laboratory tests Residential buildings Soil moisture Substrates Water table |
title | The delayed effects of flooding a residential building – case study |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-30T23%3A50%3A09IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_doaj_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=The%20delayed%20effects%20of%20flooding%20a%20residential%20building%20%E2%80%93%20case%20study&rft.jtitle=MATEC%20web%20of%20conferences&rft.au=Stra%C5%BC,%20Grzegorz&rft.date=2019&rft.volume=284&rft.spage=3009&rft.pages=3009-&rft.issn=2261-236X&rft.eissn=2261-236X&rft_id=info:doi/10.1051/matecconf/201928403009&rft_dat=%3Cproquest_doaj_%3E2277007817%3C/proquest_doaj_%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c1899-e12b84f7927199ac29a0171eb8573c685526cef9afd95908e161d252b5d65d013%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2277007817&rft_id=info:pmid/&rfr_iscdi=true |