Loading…
Photoelastic analysis of all-on-four concept using different implants angulations for maxilla
Conventional tilted implants are used in oral rehabilitation for heavily absorbed maxilla to avoid bone grafts; however, few research studies evaluate the biomechanical behavior when different angulations of the implants are used. The aim of this study was evaluate, trough photoelastic method, two d...
Saved in:
Published in: | Brazilian oral research 2014, Vol.28 (1), p.1-7 |
---|---|
Main Authors: | , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c482t-d6d55858fcbbf3e944a0bc134b835701349855bda9e1d62c4f4e64404e5e6653 |
---|---|
cites | cdi_FETCH-LOGICAL-c482t-d6d55858fcbbf3e944a0bc134b835701349855bda9e1d62c4f4e64404e5e6653 |
container_end_page | 7 |
container_issue | 1 |
container_start_page | 1 |
container_title | Brazilian oral research |
container_volume | 28 |
creator | Cidade, Castelo Pedro Vemba Pimentel, Marcele Jardim Amaral, Regiane Cristina do Nóbilo, Mauro Antonio de Arruda Barbosa, José Ricardo de Albergaria |
description | Conventional tilted implants are used in oral rehabilitation for heavily absorbed maxilla to avoid bone grafts; however, few research studies evaluate the biomechanical behavior when different angulations of the implants are used. The aim of this study was evaluate, trough photoelastic method, two different angulations and length of the cantilever in fixed implant-supported maxillary complete dentures. Two groups were evaluated: G15 (distal tilted implants 15°) and G35 (distal tilted implants 35°) n = 6. For each model, 2 distal tilted implants (3.5 x 15 mm long cylindrical cone) and 2 parallel tilted implants in the anterior region (3.5 x 10 mm) were installed. Photoelastic models were submitted to three vertical load tests: in the end of cantilever, in the last pillar and in the all pillars at the same time. We obtained the shear stress by Fringes software and found values for total, cervical and apical stress. The quantitative analysis was performed using the Student tests and Mann-Whitney test; p ≥ 0.05. There is no difference between G15 and G35 for total stress regardless of load type. Analyzing the apical region, G35 reduced strain values considering the distal loads (in the cantilever p = 0.03 and in the last pillar p = 0.02), without increasing the stress level in the cervical region. Considering the load in all pillars, G35 showed higher stress concentration in the cervical region (p = 0.04). For distal loads, G15 showed increase of tension in the apical region, while for load in all pillars, G35 inclination increases stress values in the cervical region. |
doi_str_mv | 10.1590/1807-3107BOR-2014.vol28.0051 |
format | article |
fullrecord | <record><control><sourceid>proquest_doaj_</sourceid><recordid>TN_cdi_doaj_primary_oai_doaj_org_article_aaf93ebb70494568b17e499fe7fbff49</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><scielo_id>S1806_83242014000100259</scielo_id><doaj_id>oai_doaj_org_article_aaf93ebb70494568b17e499fe7fbff49</doaj_id><sourcerecordid>1563982810</sourcerecordid><originalsourceid>FETCH-LOGICAL-c482t-d6d55858fcbbf3e944a0bc134b835701349855bda9e1d62c4f4e64404e5e6653</originalsourceid><addsrcrecordid>eNo9kU-PFCEQxTtG4_7Rr2D64MFLjwUNNCRedKPuJpus0b0aAnQxMqGbEbqN--3tnhnnRAXqVfHer6reEtgQruA9kdA1LYHu08P3hgJhmz8pUrkB4ORZdXl-fn6oRSNbyi6qq1J2AIJIIV5WF5RTqjqpLquf336lKWE0ZQquNqOJTyWUOvnaxNiksfFpzrVLo8P9VM8ljNu6D95jxnGqw7CPZpzKItzO0UwhjaX2KdeD-RtiNK-qF97Egq9P53X1-OXz481tc__w9e7m433jmKRT04uec8mld9b6FhVjBqwjLbOy5R0shZKc294oJL2gjnmGgjFgyFEI3l5Xd8exfTI7vc9hMPlJJxP04SLlrTZ58RdRG-NVi9Z2wBTjQlrSIVPKY-et90wtszbHWcUFjEnvFv9LKkX_WNPUa5pr6ABAAChfBe-Ogn1Ov2cskx5Ccbi4HzHNRRMuWiWpJLC0fji2upxKyejPfyWgV7h6padPcPW6Rx_g6hXuIn9z2jTbAfuz-D_N9h84CKBV</addsrcrecordid><sourcetype>Open Website</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1563982810</pqid></control><display><type>article</type><title>Photoelastic analysis of all-on-four concept using different implants angulations for maxilla</title><source>SciELO</source><creator>Cidade, Castelo Pedro Vemba ; Pimentel, Marcele Jardim ; Amaral, Regiane Cristina do ; Nóbilo, Mauro Antonio de Arruda ; Barbosa, José Ricardo de Albergaria</creator><creatorcontrib>Cidade, Castelo Pedro Vemba ; Pimentel, Marcele Jardim ; Amaral, Regiane Cristina do ; Nóbilo, Mauro Antonio de Arruda ; Barbosa, José Ricardo de Albergaria</creatorcontrib><description>Conventional tilted implants are used in oral rehabilitation for heavily absorbed maxilla to avoid bone grafts; however, few research studies evaluate the biomechanical behavior when different angulations of the implants are used. The aim of this study was evaluate, trough photoelastic method, two different angulations and length of the cantilever in fixed implant-supported maxillary complete dentures. Two groups were evaluated: G15 (distal tilted implants 15°) and G35 (distal tilted implants 35°) n = 6. For each model, 2 distal tilted implants (3.5 x 15 mm long cylindrical cone) and 2 parallel tilted implants in the anterior region (3.5 x 10 mm) were installed. Photoelastic models were submitted to three vertical load tests: in the end of cantilever, in the last pillar and in the all pillars at the same time. We obtained the shear stress by Fringes software and found values for total, cervical and apical stress. The quantitative analysis was performed using the Student tests and Mann-Whitney test; p ≥ 0.05. There is no difference between G15 and G35 for total stress regardless of load type. Analyzing the apical region, G35 reduced strain values considering the distal loads (in the cantilever p = 0.03 and in the last pillar p = 0.02), without increasing the stress level in the cervical region. Considering the load in all pillars, G35 showed higher stress concentration in the cervical region (p = 0.04). For distal loads, G15 showed increase of tension in the apical region, while for load in all pillars, G35 inclination increases stress values in the cervical region.</description><identifier>ISSN: 1806-8324</identifier><identifier>ISSN: 1807-3107</identifier><identifier>EISSN: 1807-3107</identifier><identifier>DOI: 10.1590/1807-3107BOR-2014.vol28.0051</identifier><identifier>PMID: 25229789</identifier><language>eng</language><publisher>Brazil: Sociedade Brasileira de Pesquisa Odontológica - SBPqO</publisher><subject>Bone Resorption ; Dental Implants ; Dental Prosthesis, Implant-Supported - methods ; Dental Stress Analysis ; Dentistry ; DENTISTRY, ORAL SURGERY & MEDICINE ; Denture Design ; Denture, Complete, Upper ; Elastic Modulus ; Humans ; Materials Testing ; Maxilla ; Models, Biological ; Reference Values ; Shear Strength ; Statistics, Nonparametric ; Stress, Mechanical ; Time Factors</subject><ispartof>Brazilian oral research, 2014, Vol.28 (1), p.1-7</ispartof><rights>This work is licensed under a Creative Commons Attribution-NonCommercial 3.0 International License.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c482t-d6d55858fcbbf3e944a0bc134b835701349855bda9e1d62c4f4e64404e5e6653</citedby><cites>FETCH-LOGICAL-c482t-d6d55858fcbbf3e944a0bc134b835701349855bda9e1d62c4f4e64404e5e6653</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>230,314,780,784,885,4024,24150,27923,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/25229789$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Cidade, Castelo Pedro Vemba</creatorcontrib><creatorcontrib>Pimentel, Marcele Jardim</creatorcontrib><creatorcontrib>Amaral, Regiane Cristina do</creatorcontrib><creatorcontrib>Nóbilo, Mauro Antonio de Arruda</creatorcontrib><creatorcontrib>Barbosa, José Ricardo de Albergaria</creatorcontrib><title>Photoelastic analysis of all-on-four concept using different implants angulations for maxilla</title><title>Brazilian oral research</title><addtitle>Braz Oral Res</addtitle><description>Conventional tilted implants are used in oral rehabilitation for heavily absorbed maxilla to avoid bone grafts; however, few research studies evaluate the biomechanical behavior when different angulations of the implants are used. The aim of this study was evaluate, trough photoelastic method, two different angulations and length of the cantilever in fixed implant-supported maxillary complete dentures. Two groups were evaluated: G15 (distal tilted implants 15°) and G35 (distal tilted implants 35°) n = 6. For each model, 2 distal tilted implants (3.5 x 15 mm long cylindrical cone) and 2 parallel tilted implants in the anterior region (3.5 x 10 mm) were installed. Photoelastic models were submitted to three vertical load tests: in the end of cantilever, in the last pillar and in the all pillars at the same time. We obtained the shear stress by Fringes software and found values for total, cervical and apical stress. The quantitative analysis was performed using the Student tests and Mann-Whitney test; p ≥ 0.05. There is no difference between G15 and G35 for total stress regardless of load type. Analyzing the apical region, G35 reduced strain values considering the distal loads (in the cantilever p = 0.03 and in the last pillar p = 0.02), without increasing the stress level in the cervical region. Considering the load in all pillars, G35 showed higher stress concentration in the cervical region (p = 0.04). For distal loads, G15 showed increase of tension in the apical region, while for load in all pillars, G35 inclination increases stress values in the cervical region.</description><subject>Bone Resorption</subject><subject>Dental Implants</subject><subject>Dental Prosthesis, Implant-Supported - methods</subject><subject>Dental Stress Analysis</subject><subject>Dentistry</subject><subject>DENTISTRY, ORAL SURGERY & MEDICINE</subject><subject>Denture Design</subject><subject>Denture, Complete, Upper</subject><subject>Elastic Modulus</subject><subject>Humans</subject><subject>Materials Testing</subject><subject>Maxilla</subject><subject>Models, Biological</subject><subject>Reference Values</subject><subject>Shear Strength</subject><subject>Statistics, Nonparametric</subject><subject>Stress, Mechanical</subject><subject>Time Factors</subject><issn>1806-8324</issn><issn>1807-3107</issn><issn>1807-3107</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2014</creationdate><recordtype>article</recordtype><sourceid>DOA</sourceid><recordid>eNo9kU-PFCEQxTtG4_7Rr2D64MFLjwUNNCRedKPuJpus0b0aAnQxMqGbEbqN--3tnhnnRAXqVfHer6reEtgQruA9kdA1LYHu08P3hgJhmz8pUrkB4ORZdXl-fn6oRSNbyi6qq1J2AIJIIV5WF5RTqjqpLquf336lKWE0ZQquNqOJTyWUOvnaxNiksfFpzrVLo8P9VM8ljNu6D95jxnGqw7CPZpzKItzO0UwhjaX2KdeD-RtiNK-qF97Egq9P53X1-OXz481tc__w9e7m433jmKRT04uec8mld9b6FhVjBqwjLbOy5R0shZKc294oJL2gjnmGgjFgyFEI3l5Xd8exfTI7vc9hMPlJJxP04SLlrTZ58RdRG-NVi9Z2wBTjQlrSIVPKY-et90wtszbHWcUFjEnvFv9LKkX_WNPUa5pr6ABAAChfBe-Ogn1Ov2cskx5Ccbi4HzHNRRMuWiWpJLC0fji2upxKyejPfyWgV7h6padPcPW6Rx_g6hXuIn9z2jTbAfuz-D_N9h84CKBV</recordid><startdate>2014</startdate><enddate>2014</enddate><creator>Cidade, Castelo Pedro Vemba</creator><creator>Pimentel, Marcele Jardim</creator><creator>Amaral, Regiane Cristina do</creator><creator>Nóbilo, Mauro Antonio de Arruda</creator><creator>Barbosa, José Ricardo de Albergaria</creator><general>Sociedade Brasileira de Pesquisa Odontológica - SBPqO</general><general>Sociedade Brasileira de Pesquisa Odontológica</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>GPN</scope><scope>DOA</scope></search><sort><creationdate>2014</creationdate><title>Photoelastic analysis of all-on-four concept using different implants angulations for maxilla</title><author>Cidade, Castelo Pedro Vemba ; Pimentel, Marcele Jardim ; Amaral, Regiane Cristina do ; Nóbilo, Mauro Antonio de Arruda ; Barbosa, José Ricardo de Albergaria</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c482t-d6d55858fcbbf3e944a0bc134b835701349855bda9e1d62c4f4e64404e5e6653</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2014</creationdate><topic>Bone Resorption</topic><topic>Dental Implants</topic><topic>Dental Prosthesis, Implant-Supported - methods</topic><topic>Dental Stress Analysis</topic><topic>Dentistry</topic><topic>DENTISTRY, ORAL SURGERY & MEDICINE</topic><topic>Denture Design</topic><topic>Denture, Complete, Upper</topic><topic>Elastic Modulus</topic><topic>Humans</topic><topic>Materials Testing</topic><topic>Maxilla</topic><topic>Models, Biological</topic><topic>Reference Values</topic><topic>Shear Strength</topic><topic>Statistics, Nonparametric</topic><topic>Stress, Mechanical</topic><topic>Time Factors</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Cidade, Castelo Pedro Vemba</creatorcontrib><creatorcontrib>Pimentel, Marcele Jardim</creatorcontrib><creatorcontrib>Amaral, Regiane Cristina do</creatorcontrib><creatorcontrib>Nóbilo, Mauro Antonio de Arruda</creatorcontrib><creatorcontrib>Barbosa, José Ricardo de Albergaria</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>SciELO</collection><collection>Directory of Open Access Journals</collection><jtitle>Brazilian oral research</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Cidade, Castelo Pedro Vemba</au><au>Pimentel, Marcele Jardim</au><au>Amaral, Regiane Cristina do</au><au>Nóbilo, Mauro Antonio de Arruda</au><au>Barbosa, José Ricardo de Albergaria</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Photoelastic analysis of all-on-four concept using different implants angulations for maxilla</atitle><jtitle>Brazilian oral research</jtitle><addtitle>Braz Oral Res</addtitle><date>2014</date><risdate>2014</risdate><volume>28</volume><issue>1</issue><spage>1</spage><epage>7</epage><pages>1-7</pages><issn>1806-8324</issn><issn>1807-3107</issn><eissn>1807-3107</eissn><abstract>Conventional tilted implants are used in oral rehabilitation for heavily absorbed maxilla to avoid bone grafts; however, few research studies evaluate the biomechanical behavior when different angulations of the implants are used. The aim of this study was evaluate, trough photoelastic method, two different angulations and length of the cantilever in fixed implant-supported maxillary complete dentures. Two groups were evaluated: G15 (distal tilted implants 15°) and G35 (distal tilted implants 35°) n = 6. For each model, 2 distal tilted implants (3.5 x 15 mm long cylindrical cone) and 2 parallel tilted implants in the anterior region (3.5 x 10 mm) were installed. Photoelastic models were submitted to three vertical load tests: in the end of cantilever, in the last pillar and in the all pillars at the same time. We obtained the shear stress by Fringes software and found values for total, cervical and apical stress. The quantitative analysis was performed using the Student tests and Mann-Whitney test; p ≥ 0.05. There is no difference between G15 and G35 for total stress regardless of load type. Analyzing the apical region, G35 reduced strain values considering the distal loads (in the cantilever p = 0.03 and in the last pillar p = 0.02), without increasing the stress level in the cervical region. Considering the load in all pillars, G35 showed higher stress concentration in the cervical region (p = 0.04). For distal loads, G15 showed increase of tension in the apical region, while for load in all pillars, G35 inclination increases stress values in the cervical region.</abstract><cop>Brazil</cop><pub>Sociedade Brasileira de Pesquisa Odontológica - SBPqO</pub><pmid>25229789</pmid><doi>10.1590/1807-3107BOR-2014.vol28.0051</doi><tpages>7</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1806-8324 |
ispartof | Brazilian oral research, 2014, Vol.28 (1), p.1-7 |
issn | 1806-8324 1807-3107 1807-3107 |
language | eng |
recordid | cdi_doaj_primary_oai_doaj_org_article_aaf93ebb70494568b17e499fe7fbff49 |
source | SciELO |
subjects | Bone Resorption Dental Implants Dental Prosthesis, Implant-Supported - methods Dental Stress Analysis Dentistry DENTISTRY, ORAL SURGERY & MEDICINE Denture Design Denture, Complete, Upper Elastic Modulus Humans Materials Testing Maxilla Models, Biological Reference Values Shear Strength Statistics, Nonparametric Stress, Mechanical Time Factors |
title | Photoelastic analysis of all-on-four concept using different implants angulations for maxilla |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-07T10%3A53%3A30IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_doaj_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Photoelastic%20analysis%20of%20all-on-four%20concept%20using%20different%20implants%20angulations%20for%20maxilla&rft.jtitle=Brazilian%20oral%20research&rft.au=Cidade,%20Castelo%20Pedro%20Vemba&rft.date=2014&rft.volume=28&rft.issue=1&rft.spage=1&rft.epage=7&rft.pages=1-7&rft.issn=1806-8324&rft.eissn=1807-3107&rft_id=info:doi/10.1590/1807-3107BOR-2014.vol28.0051&rft_dat=%3Cproquest_doaj_%3E1563982810%3C/proquest_doaj_%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c482t-d6d55858fcbbf3e944a0bc134b835701349855bda9e1d62c4f4e64404e5e6653%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=1563982810&rft_id=info:pmid/25229789&rft_scielo_id=S1806_83242014000100259&rfr_iscdi=true |