Loading…

Photoelastic analysis of all-on-four concept using different implants angulations for maxilla

Conventional tilted implants are used in oral rehabilitation for heavily absorbed maxilla to avoid bone grafts; however, few research studies evaluate the biomechanical behavior when different angulations of the implants are used. The aim of this study was evaluate, trough photoelastic method, two d...

Full description

Saved in:
Bibliographic Details
Published in:Brazilian oral research 2014, Vol.28 (1), p.1-7
Main Authors: Cidade, Castelo Pedro Vemba, Pimentel, Marcele Jardim, Amaral, Regiane Cristina do, Nóbilo, Mauro Antonio de Arruda, Barbosa, José Ricardo de Albergaria
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c482t-d6d55858fcbbf3e944a0bc134b835701349855bda9e1d62c4f4e64404e5e6653
cites cdi_FETCH-LOGICAL-c482t-d6d55858fcbbf3e944a0bc134b835701349855bda9e1d62c4f4e64404e5e6653
container_end_page 7
container_issue 1
container_start_page 1
container_title Brazilian oral research
container_volume 28
creator Cidade, Castelo Pedro Vemba
Pimentel, Marcele Jardim
Amaral, Regiane Cristina do
Nóbilo, Mauro Antonio de Arruda
Barbosa, José Ricardo de Albergaria
description Conventional tilted implants are used in oral rehabilitation for heavily absorbed maxilla to avoid bone grafts; however, few research studies evaluate the biomechanical behavior when different angulations of the implants are used. The aim of this study was evaluate, trough photoelastic method, two different angulations and length of the cantilever in fixed implant-supported maxillary complete dentures. Two groups were evaluated: G15 (distal tilted implants 15°) and G35 (distal tilted implants 35°) n = 6. For each model, 2 distal tilted implants (3.5 x 15 mm long cylindrical cone) and 2 parallel tilted implants in the anterior region (3.5 x 10 mm) were installed. Photoelastic models were submitted to three vertical load tests: in the end of cantilever, in the last pillar and in the all pillars at the same time. We obtained the shear stress by Fringes software and found values for total, cervical and apical stress. The quantitative analysis was performed using the Student tests and Mann-Whitney test; p ≥ 0.05. There is no difference between G15 and G35 for total stress regardless of load type. Analyzing the apical region, G35 reduced strain values considering the distal loads (in the cantilever p = 0.03 and in the last pillar p = 0.02), without increasing the stress level in the cervical region. Considering the load in all pillars, G35 showed higher stress concentration in the cervical region (p = 0.04). For distal loads, G15 showed increase of tension in the apical region, while for load in all pillars, G35 inclination increases stress values in the cervical region.
doi_str_mv 10.1590/1807-3107BOR-2014.vol28.0051
format article
fullrecord <record><control><sourceid>proquest_doaj_</sourceid><recordid>TN_cdi_doaj_primary_oai_doaj_org_article_aaf93ebb70494568b17e499fe7fbff49</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><scielo_id>S1806_83242014000100259</scielo_id><doaj_id>oai_doaj_org_article_aaf93ebb70494568b17e499fe7fbff49</doaj_id><sourcerecordid>1563982810</sourcerecordid><originalsourceid>FETCH-LOGICAL-c482t-d6d55858fcbbf3e944a0bc134b835701349855bda9e1d62c4f4e64404e5e6653</originalsourceid><addsrcrecordid>eNo9kU-PFCEQxTtG4_7Rr2D64MFLjwUNNCRedKPuJpus0b0aAnQxMqGbEbqN--3tnhnnRAXqVfHer6reEtgQruA9kdA1LYHu08P3hgJhmz8pUrkB4ORZdXl-fn6oRSNbyi6qq1J2AIJIIV5WF5RTqjqpLquf336lKWE0ZQquNqOJTyWUOvnaxNiksfFpzrVLo8P9VM8ljNu6D95jxnGqw7CPZpzKItzO0UwhjaX2KdeD-RtiNK-qF97Egq9P53X1-OXz481tc__w9e7m433jmKRT04uec8mld9b6FhVjBqwjLbOy5R0shZKc294oJL2gjnmGgjFgyFEI3l5Xd8exfTI7vc9hMPlJJxP04SLlrTZ58RdRG-NVi9Z2wBTjQlrSIVPKY-et90wtszbHWcUFjEnvFv9LKkX_WNPUa5pr6ABAAChfBe-Ogn1Ov2cskx5Ccbi4HzHNRRMuWiWpJLC0fji2upxKyejPfyWgV7h6padPcPW6Rx_g6hXuIn9z2jTbAfuz-D_N9h84CKBV</addsrcrecordid><sourcetype>Open Website</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1563982810</pqid></control><display><type>article</type><title>Photoelastic analysis of all-on-four concept using different implants angulations for maxilla</title><source>SciELO</source><creator>Cidade, Castelo Pedro Vemba ; Pimentel, Marcele Jardim ; Amaral, Regiane Cristina do ; Nóbilo, Mauro Antonio de Arruda ; Barbosa, José Ricardo de Albergaria</creator><creatorcontrib>Cidade, Castelo Pedro Vemba ; Pimentel, Marcele Jardim ; Amaral, Regiane Cristina do ; Nóbilo, Mauro Antonio de Arruda ; Barbosa, José Ricardo de Albergaria</creatorcontrib><description>Conventional tilted implants are used in oral rehabilitation for heavily absorbed maxilla to avoid bone grafts; however, few research studies evaluate the biomechanical behavior when different angulations of the implants are used. The aim of this study was evaluate, trough photoelastic method, two different angulations and length of the cantilever in fixed implant-supported maxillary complete dentures. Two groups were evaluated: G15 (distal tilted implants 15°) and G35 (distal tilted implants 35°) n = 6. For each model, 2 distal tilted implants (3.5 x 15 mm long cylindrical cone) and 2 parallel tilted implants in the anterior region (3.5 x 10 mm) were installed. Photoelastic models were submitted to three vertical load tests: in the end of cantilever, in the last pillar and in the all pillars at the same time. We obtained the shear stress by Fringes software and found values for total, cervical and apical stress. The quantitative analysis was performed using the Student tests and Mann-Whitney test; p ≥ 0.05. There is no difference between G15 and G35 for total stress regardless of load type. Analyzing the apical region, G35 reduced strain values considering the distal loads (in the cantilever p = 0.03 and in the last pillar p = 0.02), without increasing the stress level in the cervical region. Considering the load in all pillars, G35 showed higher stress concentration in the cervical region (p = 0.04). For distal loads, G15 showed increase of tension in the apical region, while for load in all pillars, G35 inclination increases stress values in the cervical region.</description><identifier>ISSN: 1806-8324</identifier><identifier>ISSN: 1807-3107</identifier><identifier>EISSN: 1807-3107</identifier><identifier>DOI: 10.1590/1807-3107BOR-2014.vol28.0051</identifier><identifier>PMID: 25229789</identifier><language>eng</language><publisher>Brazil: Sociedade Brasileira de Pesquisa Odontológica - SBPqO</publisher><subject>Bone Resorption ; Dental Implants ; Dental Prosthesis, Implant-Supported - methods ; Dental Stress Analysis ; Dentistry ; DENTISTRY, ORAL SURGERY &amp; MEDICINE ; Denture Design ; Denture, Complete, Upper ; Elastic Modulus ; Humans ; Materials Testing ; Maxilla ; Models, Biological ; Reference Values ; Shear Strength ; Statistics, Nonparametric ; Stress, Mechanical ; Time Factors</subject><ispartof>Brazilian oral research, 2014, Vol.28 (1), p.1-7</ispartof><rights>This work is licensed under a Creative Commons Attribution-NonCommercial 3.0 International License.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c482t-d6d55858fcbbf3e944a0bc134b835701349855bda9e1d62c4f4e64404e5e6653</citedby><cites>FETCH-LOGICAL-c482t-d6d55858fcbbf3e944a0bc134b835701349855bda9e1d62c4f4e64404e5e6653</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>230,314,780,784,885,4024,24150,27923,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/25229789$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Cidade, Castelo Pedro Vemba</creatorcontrib><creatorcontrib>Pimentel, Marcele Jardim</creatorcontrib><creatorcontrib>Amaral, Regiane Cristina do</creatorcontrib><creatorcontrib>Nóbilo, Mauro Antonio de Arruda</creatorcontrib><creatorcontrib>Barbosa, José Ricardo de Albergaria</creatorcontrib><title>Photoelastic analysis of all-on-four concept using different implants angulations for maxilla</title><title>Brazilian oral research</title><addtitle>Braz Oral Res</addtitle><description>Conventional tilted implants are used in oral rehabilitation for heavily absorbed maxilla to avoid bone grafts; however, few research studies evaluate the biomechanical behavior when different angulations of the implants are used. The aim of this study was evaluate, trough photoelastic method, two different angulations and length of the cantilever in fixed implant-supported maxillary complete dentures. Two groups were evaluated: G15 (distal tilted implants 15°) and G35 (distal tilted implants 35°) n = 6. For each model, 2 distal tilted implants (3.5 x 15 mm long cylindrical cone) and 2 parallel tilted implants in the anterior region (3.5 x 10 mm) were installed. Photoelastic models were submitted to three vertical load tests: in the end of cantilever, in the last pillar and in the all pillars at the same time. We obtained the shear stress by Fringes software and found values for total, cervical and apical stress. The quantitative analysis was performed using the Student tests and Mann-Whitney test; p ≥ 0.05. There is no difference between G15 and G35 for total stress regardless of load type. Analyzing the apical region, G35 reduced strain values considering the distal loads (in the cantilever p = 0.03 and in the last pillar p = 0.02), without increasing the stress level in the cervical region. Considering the load in all pillars, G35 showed higher stress concentration in the cervical region (p = 0.04). For distal loads, G15 showed increase of tension in the apical region, while for load in all pillars, G35 inclination increases stress values in the cervical region.</description><subject>Bone Resorption</subject><subject>Dental Implants</subject><subject>Dental Prosthesis, Implant-Supported - methods</subject><subject>Dental Stress Analysis</subject><subject>Dentistry</subject><subject>DENTISTRY, ORAL SURGERY &amp; MEDICINE</subject><subject>Denture Design</subject><subject>Denture, Complete, Upper</subject><subject>Elastic Modulus</subject><subject>Humans</subject><subject>Materials Testing</subject><subject>Maxilla</subject><subject>Models, Biological</subject><subject>Reference Values</subject><subject>Shear Strength</subject><subject>Statistics, Nonparametric</subject><subject>Stress, Mechanical</subject><subject>Time Factors</subject><issn>1806-8324</issn><issn>1807-3107</issn><issn>1807-3107</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2014</creationdate><recordtype>article</recordtype><sourceid>DOA</sourceid><recordid>eNo9kU-PFCEQxTtG4_7Rr2D64MFLjwUNNCRedKPuJpus0b0aAnQxMqGbEbqN--3tnhnnRAXqVfHer6reEtgQruA9kdA1LYHu08P3hgJhmz8pUrkB4ORZdXl-fn6oRSNbyi6qq1J2AIJIIV5WF5RTqjqpLquf336lKWE0ZQquNqOJTyWUOvnaxNiksfFpzrVLo8P9VM8ljNu6D95jxnGqw7CPZpzKItzO0UwhjaX2KdeD-RtiNK-qF97Egq9P53X1-OXz481tc__w9e7m433jmKRT04uec8mld9b6FhVjBqwjLbOy5R0shZKc294oJL2gjnmGgjFgyFEI3l5Xd8exfTI7vc9hMPlJJxP04SLlrTZ58RdRG-NVi9Z2wBTjQlrSIVPKY-et90wtszbHWcUFjEnvFv9LKkX_WNPUa5pr6ABAAChfBe-Ogn1Ov2cskx5Ccbi4HzHNRRMuWiWpJLC0fji2upxKyejPfyWgV7h6padPcPW6Rx_g6hXuIn9z2jTbAfuz-D_N9h84CKBV</recordid><startdate>2014</startdate><enddate>2014</enddate><creator>Cidade, Castelo Pedro Vemba</creator><creator>Pimentel, Marcele Jardim</creator><creator>Amaral, Regiane Cristina do</creator><creator>Nóbilo, Mauro Antonio de Arruda</creator><creator>Barbosa, José Ricardo de Albergaria</creator><general>Sociedade Brasileira de Pesquisa Odontológica - SBPqO</general><general>Sociedade Brasileira de Pesquisa Odontológica</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>GPN</scope><scope>DOA</scope></search><sort><creationdate>2014</creationdate><title>Photoelastic analysis of all-on-four concept using different implants angulations for maxilla</title><author>Cidade, Castelo Pedro Vemba ; Pimentel, Marcele Jardim ; Amaral, Regiane Cristina do ; Nóbilo, Mauro Antonio de Arruda ; Barbosa, José Ricardo de Albergaria</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c482t-d6d55858fcbbf3e944a0bc134b835701349855bda9e1d62c4f4e64404e5e6653</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2014</creationdate><topic>Bone Resorption</topic><topic>Dental Implants</topic><topic>Dental Prosthesis, Implant-Supported - methods</topic><topic>Dental Stress Analysis</topic><topic>Dentistry</topic><topic>DENTISTRY, ORAL SURGERY &amp; MEDICINE</topic><topic>Denture Design</topic><topic>Denture, Complete, Upper</topic><topic>Elastic Modulus</topic><topic>Humans</topic><topic>Materials Testing</topic><topic>Maxilla</topic><topic>Models, Biological</topic><topic>Reference Values</topic><topic>Shear Strength</topic><topic>Statistics, Nonparametric</topic><topic>Stress, Mechanical</topic><topic>Time Factors</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Cidade, Castelo Pedro Vemba</creatorcontrib><creatorcontrib>Pimentel, Marcele Jardim</creatorcontrib><creatorcontrib>Amaral, Regiane Cristina do</creatorcontrib><creatorcontrib>Nóbilo, Mauro Antonio de Arruda</creatorcontrib><creatorcontrib>Barbosa, José Ricardo de Albergaria</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>SciELO</collection><collection>Directory of Open Access Journals</collection><jtitle>Brazilian oral research</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Cidade, Castelo Pedro Vemba</au><au>Pimentel, Marcele Jardim</au><au>Amaral, Regiane Cristina do</au><au>Nóbilo, Mauro Antonio de Arruda</au><au>Barbosa, José Ricardo de Albergaria</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Photoelastic analysis of all-on-four concept using different implants angulations for maxilla</atitle><jtitle>Brazilian oral research</jtitle><addtitle>Braz Oral Res</addtitle><date>2014</date><risdate>2014</risdate><volume>28</volume><issue>1</issue><spage>1</spage><epage>7</epage><pages>1-7</pages><issn>1806-8324</issn><issn>1807-3107</issn><eissn>1807-3107</eissn><abstract>Conventional tilted implants are used in oral rehabilitation for heavily absorbed maxilla to avoid bone grafts; however, few research studies evaluate the biomechanical behavior when different angulations of the implants are used. The aim of this study was evaluate, trough photoelastic method, two different angulations and length of the cantilever in fixed implant-supported maxillary complete dentures. Two groups were evaluated: G15 (distal tilted implants 15°) and G35 (distal tilted implants 35°) n = 6. For each model, 2 distal tilted implants (3.5 x 15 mm long cylindrical cone) and 2 parallel tilted implants in the anterior region (3.5 x 10 mm) were installed. Photoelastic models were submitted to three vertical load tests: in the end of cantilever, in the last pillar and in the all pillars at the same time. We obtained the shear stress by Fringes software and found values for total, cervical and apical stress. The quantitative analysis was performed using the Student tests and Mann-Whitney test; p ≥ 0.05. There is no difference between G15 and G35 for total stress regardless of load type. Analyzing the apical region, G35 reduced strain values considering the distal loads (in the cantilever p = 0.03 and in the last pillar p = 0.02), without increasing the stress level in the cervical region. Considering the load in all pillars, G35 showed higher stress concentration in the cervical region (p = 0.04). For distal loads, G15 showed increase of tension in the apical region, while for load in all pillars, G35 inclination increases stress values in the cervical region.</abstract><cop>Brazil</cop><pub>Sociedade Brasileira de Pesquisa Odontológica - SBPqO</pub><pmid>25229789</pmid><doi>10.1590/1807-3107BOR-2014.vol28.0051</doi><tpages>7</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1806-8324
ispartof Brazilian oral research, 2014, Vol.28 (1), p.1-7
issn 1806-8324
1807-3107
1807-3107
language eng
recordid cdi_doaj_primary_oai_doaj_org_article_aaf93ebb70494568b17e499fe7fbff49
source SciELO
subjects Bone Resorption
Dental Implants
Dental Prosthesis, Implant-Supported - methods
Dental Stress Analysis
Dentistry
DENTISTRY, ORAL SURGERY & MEDICINE
Denture Design
Denture, Complete, Upper
Elastic Modulus
Humans
Materials Testing
Maxilla
Models, Biological
Reference Values
Shear Strength
Statistics, Nonparametric
Stress, Mechanical
Time Factors
title Photoelastic analysis of all-on-four concept using different implants angulations for maxilla
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-07T10%3A53%3A30IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_doaj_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Photoelastic%20analysis%20of%20all-on-four%20concept%20using%20different%20implants%20angulations%20for%20maxilla&rft.jtitle=Brazilian%20oral%20research&rft.au=Cidade,%20Castelo%20Pedro%20Vemba&rft.date=2014&rft.volume=28&rft.issue=1&rft.spage=1&rft.epage=7&rft.pages=1-7&rft.issn=1806-8324&rft.eissn=1807-3107&rft_id=info:doi/10.1590/1807-3107BOR-2014.vol28.0051&rft_dat=%3Cproquest_doaj_%3E1563982810%3C/proquest_doaj_%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c482t-d6d55858fcbbf3e944a0bc134b835701349855bda9e1d62c4f4e64404e5e6653%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=1563982810&rft_id=info:pmid/25229789&rft_scielo_id=S1806_83242014000100259&rfr_iscdi=true