Loading…

Determination of retinol and carotenoids in selected Malaysian food products using high-performance liquid chromatography (HPLC)

The presented method is focused on simultaneous determination of retinol and two carotenoids (lutein, β-carotene) in selected Malaysian food products. A Dionex Ultimate 3000 Series High-Performance Liquid Chromatography system equipped with two Dionex Acclaim Polar Advantage II C 18 columns was util...

Full description

Saved in:
Bibliographic Details
Published in:SN applied sciences 2022-04, Vol.4 (4), p.93-16, Article 93
Main Authors: Rathi, Devi-Nair Gunasegavan, Rashed, Aswir Abd, Noh, Mohd Fairulnizal Md
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:The presented method is focused on simultaneous determination of retinol and two carotenoids (lutein, β-carotene) in selected Malaysian food products. A Dionex Ultimate 3000 Series High-Performance Liquid Chromatography system equipped with two Dionex Acclaim Polar Advantage II C 18 columns was utilized in this study. Simultaneous elution of retinol, lutein and β-carotene was achieved within 45 min with gradient profile of methanol and ultra-pure water (95:5–100:0–95:5) programmed at 0.8 mL/min flow rate and 30 °C. Retinol was acquired at 325 nm while lutein and β-carotene were acquired at 440 nm. Limits of detection and quantification of retinol and lutein were at 0.10, 0.34 µg/mL, and 0.08, 0.26 µg/mL; respectively while higher levels were observed for β-carotene at 1.06 and 3.54 µg/mL. Linearity test indicated R 2 of 0.996–0.999, along with high accuracy (71.92–116.29%) and excellent repeatability for all analytes. Extraction efficiency was determined using standard addition into representative food product with recovery obtained in the range of 61.86–116.90% for all three analytes. The developed in-house HPLC method incorporates an enclosed solid-phase extraction system that is believed to further improve sample purification and analytes detection. On the whole, the developed on-line SPE-HPLC technique and efficient sample pre-treatment is deemed a reliable approach for simultaneous determination of retinol, lutein and β-carotene, as analyzed among the selected Malaysian food products. Additionally, the described procedure could also benefit routine analysis of these analytes in other food matrices or for determination of other analytes with similar chemistry and faster elution. Article highlights A Dionex HPLC system integrated with on-line solid phase extraction within an enclosed system for improved detection of retinol, lutein and β-carotene in several food matrices. Sample processing verification via standard addition technique into selected food products. Superiority of the proposed method in comparison to other available techniques and recommendation for future applications.
ISSN:2523-3963
2523-3971
DOI:10.1007/s42452-022-04955-8