Loading…

Analysis of Leakage Impedance Variations Due to Cross-Sectional Area Changes in High Voltage Sections

Transformers are crucial devices in electrical power systems, playing a key role in voltage regulation, power transmission, and distribution. Leakage impedance is one of the main factors influencing the transformer's performance. Leakage impedance affects the efficiency and stability of the pow...

Full description

Saved in:
Bibliographic Details
Published in:IEEE access 2024, Vol.12, p.170379-170386
Main Authors: Dawood, Kamran, Tursun, Semih, Komurgoz, Guven
Format: Article
Language:English
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites
container_end_page 170386
container_issue
container_start_page 170379
container_title IEEE access
container_volume 12
creator Dawood, Kamran
Tursun, Semih
Komurgoz, Guven
description Transformers are crucial devices in electrical power systems, playing a key role in voltage regulation, power transmission, and distribution. Leakage impedance is one of the main factors influencing the transformer's performance. Leakage impedance affects the efficiency and stability of the power transformers. This paper focuses on the numerical estimation for the calculation of leakage impedance with three sections in the primary winding (high-voltage winding) and a single section in the secondary winding (low-voltage winding). This paper aims to comprehensively examine the variations that arise from the different cross-sectional areas of the various sections of the high-voltage winding, as well as how these variations affect the transformer's overall leakage impedance. This study focuses on examining the effect of different cross-section areas of the high-voltage winding on leakage impedance. Finite element analysis is used to measure and evaluate the leakage impedance of the transformer under different configurations. This study examines the impact of cross-sectional area variations on the transformer's leakage impedance, highlighting the crucial roles of impedance and inductance.
doi_str_mv 10.1109/ACCESS.2024.3487300
format article
fullrecord <record><control><sourceid>doaj_cross</sourceid><recordid>TN_cdi_doaj_primary_oai_doaj_org_article_ab9e1aa372924265bb81ae0b895df939</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>10737064</ieee_id><doaj_id>oai_doaj_org_article_ab9e1aa372924265bb81ae0b895df939</doaj_id><sourcerecordid>oai_doaj_org_article_ab9e1aa372924265bb81ae0b895df939</sourcerecordid><originalsourceid>FETCH-LOGICAL-c216t-6bf1c3f41db348eb00958d4b7a9434f0f52a460ce5f4cc41d4a590707f82b2593</originalsourceid><addsrcrecordid>eNpNkE1OwzAQhSMEEhX0BLDwBVL8m8TLKhRaqRKLQrfW2Bm3LmlSxWHB7UlohZjNjJ7mfZp5SfLA6Iwxqp_mZbnYbGaccjkTssgFpVfJhLNMp0KJ7PrffJtMYzzQoYpBUvkkwXkD9XcMkbSerBE-YYdkdTxhBY1DsoUuQB_aJpLnLyR9S8qujTHdoBtVqMm8QyDlHpodRhIasgy7Pdm2dT-CLmvxPrnxUEecXvpd8vGyeC-X6frtdVXO16kbTuzTzHrmhJesssMjaCnVqqikzUFLIT31ioPMqEPlpXPDmgSlaU5zX3DLlRZ3yerMrVo4mFMXjtB9mxaC-RXabmeg64Or0YDVyABEzjWXPFPWFgyQ2kKrymsxssSZ5caPO_R_PEbNGLw5B2_G4M0l-MH1eHYFRPznyEVOMyl-AHFxftY</addsrcrecordid><sourcetype>Open Website</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Analysis of Leakage Impedance Variations Due to Cross-Sectional Area Changes in High Voltage Sections</title><source>IEEE Xplore Open Access Journals</source><creator>Dawood, Kamran ; Tursun, Semih ; Komurgoz, Guven</creator><creatorcontrib>Dawood, Kamran ; Tursun, Semih ; Komurgoz, Guven</creatorcontrib><description>Transformers are crucial devices in electrical power systems, playing a key role in voltage regulation, power transmission, and distribution. Leakage impedance is one of the main factors influencing the transformer's performance. Leakage impedance affects the efficiency and stability of the power transformers. This paper focuses on the numerical estimation for the calculation of leakage impedance with three sections in the primary winding (high-voltage winding) and a single section in the secondary winding (low-voltage winding). This paper aims to comprehensively examine the variations that arise from the different cross-sectional areas of the various sections of the high-voltage winding, as well as how these variations affect the transformer's overall leakage impedance. This study focuses on examining the effect of different cross-section areas of the high-voltage winding on leakage impedance. Finite element analysis is used to measure and evaluate the leakage impedance of the transformer under different configurations. This study examines the impact of cross-sectional area variations on the transformer's leakage impedance, highlighting the crucial roles of impedance and inductance.</description><identifier>ISSN: 2169-3536</identifier><identifier>EISSN: 2169-3536</identifier><identifier>DOI: 10.1109/ACCESS.2024.3487300</identifier><identifier>CODEN: IAECCG</identifier><language>eng</language><publisher>IEEE</publisher><subject>Analytical models ; Cross-section ; dry-type transformer ; Finite element analysis ; High-voltage techniques ; Impedance ; leakage impedance ; Magnetostatics ; Mathematical models ; Numerical models ; Power transformer insulation ; Solid modeling ; Windings</subject><ispartof>IEEE access, 2024, Vol.12, p.170379-170386</ispartof><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><orcidid>0000-0001-6975-1011</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/10737064$$EHTML$$P50$$Gieee$$Hfree_for_read</linktohtml><link.rule.ids>314,780,784,4024,27633,27923,27924,27925,54933</link.rule.ids></links><search><creatorcontrib>Dawood, Kamran</creatorcontrib><creatorcontrib>Tursun, Semih</creatorcontrib><creatorcontrib>Komurgoz, Guven</creatorcontrib><title>Analysis of Leakage Impedance Variations Due to Cross-Sectional Area Changes in High Voltage Sections</title><title>IEEE access</title><addtitle>Access</addtitle><description>Transformers are crucial devices in electrical power systems, playing a key role in voltage regulation, power transmission, and distribution. Leakage impedance is one of the main factors influencing the transformer's performance. Leakage impedance affects the efficiency and stability of the power transformers. This paper focuses on the numerical estimation for the calculation of leakage impedance with three sections in the primary winding (high-voltage winding) and a single section in the secondary winding (low-voltage winding). This paper aims to comprehensively examine the variations that arise from the different cross-sectional areas of the various sections of the high-voltage winding, as well as how these variations affect the transformer's overall leakage impedance. This study focuses on examining the effect of different cross-section areas of the high-voltage winding on leakage impedance. Finite element analysis is used to measure and evaluate the leakage impedance of the transformer under different configurations. This study examines the impact of cross-sectional area variations on the transformer's leakage impedance, highlighting the crucial roles of impedance and inductance.</description><subject>Analytical models</subject><subject>Cross-section</subject><subject>dry-type transformer</subject><subject>Finite element analysis</subject><subject>High-voltage techniques</subject><subject>Impedance</subject><subject>leakage impedance</subject><subject>Magnetostatics</subject><subject>Mathematical models</subject><subject>Numerical models</subject><subject>Power transformer insulation</subject><subject>Solid modeling</subject><subject>Windings</subject><issn>2169-3536</issn><issn>2169-3536</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><sourceid>ESBDL</sourceid><sourceid>DOA</sourceid><recordid>eNpNkE1OwzAQhSMEEhX0BLDwBVL8m8TLKhRaqRKLQrfW2Bm3LmlSxWHB7UlohZjNjJ7mfZp5SfLA6Iwxqp_mZbnYbGaccjkTssgFpVfJhLNMp0KJ7PrffJtMYzzQoYpBUvkkwXkD9XcMkbSerBE-YYdkdTxhBY1DsoUuQB_aJpLnLyR9S8qujTHdoBtVqMm8QyDlHpodRhIasgy7Pdm2dT-CLmvxPrnxUEecXvpd8vGyeC-X6frtdVXO16kbTuzTzHrmhJesssMjaCnVqqikzUFLIT31ioPMqEPlpXPDmgSlaU5zX3DLlRZ3yerMrVo4mFMXjtB9mxaC-RXabmeg64Or0YDVyABEzjWXPFPWFgyQ2kKrymsxssSZ5caPO_R_PEbNGLw5B2_G4M0l-MH1eHYFRPznyEVOMyl-AHFxftY</recordid><startdate>2024</startdate><enddate>2024</enddate><creator>Dawood, Kamran</creator><creator>Tursun, Semih</creator><creator>Komurgoz, Guven</creator><general>IEEE</general><scope>97E</scope><scope>ESBDL</scope><scope>RIA</scope><scope>RIE</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>DOA</scope><orcidid>https://orcid.org/0000-0001-6975-1011</orcidid></search><sort><creationdate>2024</creationdate><title>Analysis of Leakage Impedance Variations Due to Cross-Sectional Area Changes in High Voltage Sections</title><author>Dawood, Kamran ; Tursun, Semih ; Komurgoz, Guven</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c216t-6bf1c3f41db348eb00958d4b7a9434f0f52a460ce5f4cc41d4a590707f82b2593</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><topic>Analytical models</topic><topic>Cross-section</topic><topic>dry-type transformer</topic><topic>Finite element analysis</topic><topic>High-voltage techniques</topic><topic>Impedance</topic><topic>leakage impedance</topic><topic>Magnetostatics</topic><topic>Mathematical models</topic><topic>Numerical models</topic><topic>Power transformer insulation</topic><topic>Solid modeling</topic><topic>Windings</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Dawood, Kamran</creatorcontrib><creatorcontrib>Tursun, Semih</creatorcontrib><creatorcontrib>Komurgoz, Guven</creatorcontrib><collection>IEEE All-Society Periodicals Package (ASPP) 2005-present</collection><collection>IEEE Xplore Open Access Journals</collection><collection>IEEE All-Society Periodicals Package (ASPP) 1998-Present</collection><collection>IEEE Xplore</collection><collection>CrossRef</collection><collection>DOAJ Directory of Open Access Journals</collection><jtitle>IEEE access</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Dawood, Kamran</au><au>Tursun, Semih</au><au>Komurgoz, Guven</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Analysis of Leakage Impedance Variations Due to Cross-Sectional Area Changes in High Voltage Sections</atitle><jtitle>IEEE access</jtitle><stitle>Access</stitle><date>2024</date><risdate>2024</risdate><volume>12</volume><spage>170379</spage><epage>170386</epage><pages>170379-170386</pages><issn>2169-3536</issn><eissn>2169-3536</eissn><coden>IAECCG</coden><abstract>Transformers are crucial devices in electrical power systems, playing a key role in voltage regulation, power transmission, and distribution. Leakage impedance is one of the main factors influencing the transformer's performance. Leakage impedance affects the efficiency and stability of the power transformers. This paper focuses on the numerical estimation for the calculation of leakage impedance with three sections in the primary winding (high-voltage winding) and a single section in the secondary winding (low-voltage winding). This paper aims to comprehensively examine the variations that arise from the different cross-sectional areas of the various sections of the high-voltage winding, as well as how these variations affect the transformer's overall leakage impedance. This study focuses on examining the effect of different cross-section areas of the high-voltage winding on leakage impedance. Finite element analysis is used to measure and evaluate the leakage impedance of the transformer under different configurations. This study examines the impact of cross-sectional area variations on the transformer's leakage impedance, highlighting the crucial roles of impedance and inductance.</abstract><pub>IEEE</pub><doi>10.1109/ACCESS.2024.3487300</doi><tpages>8</tpages><orcidid>https://orcid.org/0000-0001-6975-1011</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 2169-3536
ispartof IEEE access, 2024, Vol.12, p.170379-170386
issn 2169-3536
2169-3536
language eng
recordid cdi_doaj_primary_oai_doaj_org_article_ab9e1aa372924265bb81ae0b895df939
source IEEE Xplore Open Access Journals
subjects Analytical models
Cross-section
dry-type transformer
Finite element analysis
High-voltage techniques
Impedance
leakage impedance
Magnetostatics
Mathematical models
Numerical models
Power transformer insulation
Solid modeling
Windings
title Analysis of Leakage Impedance Variations Due to Cross-Sectional Area Changes in High Voltage Sections
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-04T19%3A47%3A07IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-doaj_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Analysis%20of%20Leakage%20Impedance%20Variations%20Due%20to%20Cross-Sectional%20Area%20Changes%20in%20High%20Voltage%20Sections&rft.jtitle=IEEE%20access&rft.au=Dawood,%20Kamran&rft.date=2024&rft.volume=12&rft.spage=170379&rft.epage=170386&rft.pages=170379-170386&rft.issn=2169-3536&rft.eissn=2169-3536&rft.coden=IAECCG&rft_id=info:doi/10.1109/ACCESS.2024.3487300&rft_dat=%3Cdoaj_cross%3Eoai_doaj_org_article_ab9e1aa372924265bb81ae0b895df939%3C/doaj_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c216t-6bf1c3f41db348eb00958d4b7a9434f0f52a460ce5f4cc41d4a590707f82b2593%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=10737064&rfr_iscdi=true