Loading…

Electrode Size and Placement for Surface EMG Bipolar Detection from the Brachioradialis Muscle: A Scoping Review

The brachioradialis muscle (BRD) is one of the main elbow flexors and is often assessed by surface electromyography (sEMG) in physiology, clinical, sports, ergonomics, and bioengineering applications. The reliability of the sEMG measurement strongly relies on the characteristics of the detection sys...

Full description

Saved in:
Bibliographic Details
Published in:Sensors (Basel, Switzerland) Switzerland), 2021-11, Vol.21 (21), p.7322
Main Authors: Merlo, Andrea, Bò, Maria Chiara, Campanini, Isabella
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c469t-7cda7f95b79f7d8c6b0d9c16080912a577e354905923fa7af1523ed3613e54833
cites cdi_FETCH-LOGICAL-c469t-7cda7f95b79f7d8c6b0d9c16080912a577e354905923fa7af1523ed3613e54833
container_end_page
container_issue 21
container_start_page 7322
container_title Sensors (Basel, Switzerland)
container_volume 21
creator Merlo, Andrea
Bò, Maria Chiara
Campanini, Isabella
description The brachioradialis muscle (BRD) is one of the main elbow flexors and is often assessed by surface electromyography (sEMG) in physiology, clinical, sports, ergonomics, and bioengineering applications. The reliability of the sEMG measurement strongly relies on the characteristics of the detection system used, because of possible crosstalk from the surrounding forearm muscles. We conducted a scoping review of the main databases to explore available guidelines of electrode placement on BRD and to map the electrode configurations used and authors' awareness on the issues of crosstalk. One hundred and thirty-four studies were included in the review. The crosstalk was mentioned in 29 studies, although two studies only were specifically designed to assess it. One hundred and six studies (79%) did not even address the issue by generically placing the sensors above BRD, usually choosing large disposable ECG electrodes. The analysis of the literature highlights a general lack of awareness on the issues of crosstalk and the need for adequate training in the sEMG field. Three guidelines were found, whose recommendations have been compared and summarized to promote reliability in further studies. In particular, it is crucial to use miniaturized electrodes placed on a specific area over the muscle, especially when BRD activity is recorded for clinical applications.
doi_str_mv 10.3390/s21217322
format article
fullrecord <record><control><sourceid>proquest_doaj_</sourceid><recordid>TN_cdi_doaj_primary_oai_doaj_org_article_af044f640d544d60b797a310b86c4ddf</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><doaj_id>oai_doaj_org_article_af044f640d544d60b797a310b86c4ddf</doaj_id><sourcerecordid>2596066093</sourcerecordid><originalsourceid>FETCH-LOGICAL-c469t-7cda7f95b79f7d8c6b0d9c16080912a577e354905923fa7af1523ed3613e54833</originalsourceid><addsrcrecordid>eNpdkktvEzEUhUcIREthwR9AltjAIuC3xyyQ2hJKpVYgAmvLsa8TR5PxYM8Uwa_HISVqWfl1_N3j69M0zwl-w5jGbwsllChG6YPmmHDKZy2l-OGd-VHzpJQNxpQx1j5ujhhXCkuqjpth3oEbc_KAFvE3INt79KWzDrbQjyikjBZTDnWN5tcX6CwOqbMZfYCx3oqpRyGnLRrXgM6ydeuYsvXRdrGg66m4Dt6hU7RwaYj9Cn2Fmwg_nzaPgu0KPLsdT5rvH-ffzj_Nrj5fXJ6fXs0cl3qcKeetCloslQ7Kt04usdeOSNxiTagVSgETXGOhKQtW2UAEZeCZJAwEbxk7aS73XJ_sxgw5bm3-ZZKN5u9Gyitj8xirR2MD5jxIjr3g3EtcayrLCF620nHvQ2W937OGabkF72prsu3uQe-f9HFtVunGtKJVXJAKeHULyOnHBGU021gcdJ3tIU3FUKEVb0X9yyp9-Z90k6bc11btVBJLifXuda_3KpdTKRnCwQzBZpcJc8hE1b646_6g_BcC9gfoK7AQ</addsrcrecordid><sourcetype>Open Website</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2596066093</pqid></control><display><type>article</type><title>Electrode Size and Placement for Surface EMG Bipolar Detection from the Brachioradialis Muscle: A Scoping Review</title><source>Open Access: PubMed Central</source><source>Publicly Available Content Database</source><creator>Merlo, Andrea ; Bò, Maria Chiara ; Campanini, Isabella</creator><creatorcontrib>Merlo, Andrea ; Bò, Maria Chiara ; Campanini, Isabella</creatorcontrib><description>The brachioradialis muscle (BRD) is one of the main elbow flexors and is often assessed by surface electromyography (sEMG) in physiology, clinical, sports, ergonomics, and bioengineering applications. The reliability of the sEMG measurement strongly relies on the characteristics of the detection system used, because of possible crosstalk from the surrounding forearm muscles. We conducted a scoping review of the main databases to explore available guidelines of electrode placement on BRD and to map the electrode configurations used and authors' awareness on the issues of crosstalk. One hundred and thirty-four studies were included in the review. The crosstalk was mentioned in 29 studies, although two studies only were specifically designed to assess it. One hundred and six studies (79%) did not even address the issue by generically placing the sensors above BRD, usually choosing large disposable ECG electrodes. The analysis of the literature highlights a general lack of awareness on the issues of crosstalk and the need for adequate training in the sEMG field. Three guidelines were found, whose recommendations have been compared and summarized to promote reliability in further studies. In particular, it is crucial to use miniaturized electrodes placed on a specific area over the muscle, especially when BRD activity is recorded for clinical applications.</description><identifier>ISSN: 1424-8220</identifier><identifier>EISSN: 1424-8220</identifier><identifier>DOI: 10.3390/s21217322</identifier><identifier>PMID: 34770627</identifier><language>eng</language><publisher>Switzerland: MDPI AG</publisher><subject>Bioengineering ; Bone surgery ; brachioradialis ; Crosstalk ; Elbow ; electrode placement ; Electrodes ; Electromyography ; Ergonomics ; Flexors ; Forearm ; Guidelines ; Humans ; Investigations ; Muscle function ; Muscle, Skeletal - physiology ; Muscles ; Physiology ; Reliability ; Reproducibility of Results ; Review ; Sensors ; surface electromyography ; upper limb</subject><ispartof>Sensors (Basel, Switzerland), 2021-11, Vol.21 (21), p.7322</ispartof><rights>2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.</rights><rights>2021 by the authors. 2021</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c469t-7cda7f95b79f7d8c6b0d9c16080912a577e354905923fa7af1523ed3613e54833</citedby><cites>FETCH-LOGICAL-c469t-7cda7f95b79f7d8c6b0d9c16080912a577e354905923fa7af1523ed3613e54833</cites><orcidid>0000-0002-5587-5686 ; 0000-0002-9286-6711</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.proquest.com/docview/2596066093/fulltextPDF?pq-origsite=primo$$EPDF$$P50$$Gproquest$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.proquest.com/docview/2596066093?pq-origsite=primo$$EHTML$$P50$$Gproquest$$Hfree_for_read</linktohtml><link.rule.ids>230,314,727,780,784,885,25751,27922,27923,37010,37011,44588,53789,53791,74896</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/34770627$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Merlo, Andrea</creatorcontrib><creatorcontrib>Bò, Maria Chiara</creatorcontrib><creatorcontrib>Campanini, Isabella</creatorcontrib><title>Electrode Size and Placement for Surface EMG Bipolar Detection from the Brachioradialis Muscle: A Scoping Review</title><title>Sensors (Basel, Switzerland)</title><addtitle>Sensors (Basel)</addtitle><description>The brachioradialis muscle (BRD) is one of the main elbow flexors and is often assessed by surface electromyography (sEMG) in physiology, clinical, sports, ergonomics, and bioengineering applications. The reliability of the sEMG measurement strongly relies on the characteristics of the detection system used, because of possible crosstalk from the surrounding forearm muscles. We conducted a scoping review of the main databases to explore available guidelines of electrode placement on BRD and to map the electrode configurations used and authors' awareness on the issues of crosstalk. One hundred and thirty-four studies were included in the review. The crosstalk was mentioned in 29 studies, although two studies only were specifically designed to assess it. One hundred and six studies (79%) did not even address the issue by generically placing the sensors above BRD, usually choosing large disposable ECG electrodes. The analysis of the literature highlights a general lack of awareness on the issues of crosstalk and the need for adequate training in the sEMG field. Three guidelines were found, whose recommendations have been compared and summarized to promote reliability in further studies. In particular, it is crucial to use miniaturized electrodes placed on a specific area over the muscle, especially when BRD activity is recorded for clinical applications.</description><subject>Bioengineering</subject><subject>Bone surgery</subject><subject>brachioradialis</subject><subject>Crosstalk</subject><subject>Elbow</subject><subject>electrode placement</subject><subject>Electrodes</subject><subject>Electromyography</subject><subject>Ergonomics</subject><subject>Flexors</subject><subject>Forearm</subject><subject>Guidelines</subject><subject>Humans</subject><subject>Investigations</subject><subject>Muscle function</subject><subject>Muscle, Skeletal - physiology</subject><subject>Muscles</subject><subject>Physiology</subject><subject>Reliability</subject><subject>Reproducibility of Results</subject><subject>Review</subject><subject>Sensors</subject><subject>surface electromyography</subject><subject>upper limb</subject><issn>1424-8220</issn><issn>1424-8220</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2021</creationdate><recordtype>article</recordtype><sourceid>PIMPY</sourceid><sourceid>DOA</sourceid><recordid>eNpdkktvEzEUhUcIREthwR9AltjAIuC3xyyQ2hJKpVYgAmvLsa8TR5PxYM8Uwa_HISVqWfl1_N3j69M0zwl-w5jGbwsllChG6YPmmHDKZy2l-OGd-VHzpJQNxpQx1j5ujhhXCkuqjpth3oEbc_KAFvE3INt79KWzDrbQjyikjBZTDnWN5tcX6CwOqbMZfYCx3oqpRyGnLRrXgM6ydeuYsvXRdrGg66m4Dt6hU7RwaYj9Cn2Fmwg_nzaPgu0KPLsdT5rvH-ffzj_Nrj5fXJ6fXs0cl3qcKeetCloslQ7Kt04usdeOSNxiTagVSgETXGOhKQtW2UAEZeCZJAwEbxk7aS73XJ_sxgw5bm3-ZZKN5u9Gyitj8xirR2MD5jxIjr3g3EtcayrLCF620nHvQ2W937OGabkF72prsu3uQe-f9HFtVunGtKJVXJAKeHULyOnHBGU021gcdJ3tIU3FUKEVb0X9yyp9-Z90k6bc11btVBJLifXuda_3KpdTKRnCwQzBZpcJc8hE1b646_6g_BcC9gfoK7AQ</recordid><startdate>20211103</startdate><enddate>20211103</enddate><creator>Merlo, Andrea</creator><creator>Bò, Maria Chiara</creator><creator>Campanini, Isabella</creator><general>MDPI AG</general><general>MDPI</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>3V.</scope><scope>7X7</scope><scope>7XB</scope><scope>88E</scope><scope>8FI</scope><scope>8FJ</scope><scope>8FK</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>FYUFA</scope><scope>GHDGH</scope><scope>K9.</scope><scope>M0S</scope><scope>M1P</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>7X8</scope><scope>5PM</scope><scope>DOA</scope><orcidid>https://orcid.org/0000-0002-5587-5686</orcidid><orcidid>https://orcid.org/0000-0002-9286-6711</orcidid></search><sort><creationdate>20211103</creationdate><title>Electrode Size and Placement for Surface EMG Bipolar Detection from the Brachioradialis Muscle: A Scoping Review</title><author>Merlo, Andrea ; Bò, Maria Chiara ; Campanini, Isabella</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c469t-7cda7f95b79f7d8c6b0d9c16080912a577e354905923fa7af1523ed3613e54833</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2021</creationdate><topic>Bioengineering</topic><topic>Bone surgery</topic><topic>brachioradialis</topic><topic>Crosstalk</topic><topic>Elbow</topic><topic>electrode placement</topic><topic>Electrodes</topic><topic>Electromyography</topic><topic>Ergonomics</topic><topic>Flexors</topic><topic>Forearm</topic><topic>Guidelines</topic><topic>Humans</topic><topic>Investigations</topic><topic>Muscle function</topic><topic>Muscle, Skeletal - physiology</topic><topic>Muscles</topic><topic>Physiology</topic><topic>Reliability</topic><topic>Reproducibility of Results</topic><topic>Review</topic><topic>Sensors</topic><topic>surface electromyography</topic><topic>upper limb</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Merlo, Andrea</creatorcontrib><creatorcontrib>Bò, Maria Chiara</creatorcontrib><creatorcontrib>Campanini, Isabella</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>ProQuest Central (Corporate)</collection><collection>Health &amp; Medical Collection</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>Medical Database (Alumni Edition)</collection><collection>Hospital Premium Collection</collection><collection>Hospital Premium Collection (Alumni Edition)</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>ProQuest Central (Alumni)</collection><collection>ProQuest Central</collection><collection>ProQuest Central Essentials</collection><collection>ProQuest Central</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central Korea</collection><collection>Health Research Premium Collection</collection><collection>Health Research Premium Collection (Alumni)</collection><collection>ProQuest Health &amp; Medical Complete (Alumni)</collection><collection>Health &amp; Medical Collection (Alumni Edition)</collection><collection>Medical Database</collection><collection>Publicly Available Content Database</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><collection>Open Access: DOAJ - Directory of Open Access Journals</collection><jtitle>Sensors (Basel, Switzerland)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Merlo, Andrea</au><au>Bò, Maria Chiara</au><au>Campanini, Isabella</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Electrode Size and Placement for Surface EMG Bipolar Detection from the Brachioradialis Muscle: A Scoping Review</atitle><jtitle>Sensors (Basel, Switzerland)</jtitle><addtitle>Sensors (Basel)</addtitle><date>2021-11-03</date><risdate>2021</risdate><volume>21</volume><issue>21</issue><spage>7322</spage><pages>7322-</pages><issn>1424-8220</issn><eissn>1424-8220</eissn><abstract>The brachioradialis muscle (BRD) is one of the main elbow flexors and is often assessed by surface electromyography (sEMG) in physiology, clinical, sports, ergonomics, and bioengineering applications. The reliability of the sEMG measurement strongly relies on the characteristics of the detection system used, because of possible crosstalk from the surrounding forearm muscles. We conducted a scoping review of the main databases to explore available guidelines of electrode placement on BRD and to map the electrode configurations used and authors' awareness on the issues of crosstalk. One hundred and thirty-four studies were included in the review. The crosstalk was mentioned in 29 studies, although two studies only were specifically designed to assess it. One hundred and six studies (79%) did not even address the issue by generically placing the sensors above BRD, usually choosing large disposable ECG electrodes. The analysis of the literature highlights a general lack of awareness on the issues of crosstalk and the need for adequate training in the sEMG field. Three guidelines were found, whose recommendations have been compared and summarized to promote reliability in further studies. In particular, it is crucial to use miniaturized electrodes placed on a specific area over the muscle, especially when BRD activity is recorded for clinical applications.</abstract><cop>Switzerland</cop><pub>MDPI AG</pub><pmid>34770627</pmid><doi>10.3390/s21217322</doi><orcidid>https://orcid.org/0000-0002-5587-5686</orcidid><orcidid>https://orcid.org/0000-0002-9286-6711</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1424-8220
ispartof Sensors (Basel, Switzerland), 2021-11, Vol.21 (21), p.7322
issn 1424-8220
1424-8220
language eng
recordid cdi_doaj_primary_oai_doaj_org_article_af044f640d544d60b797a310b86c4ddf
source Open Access: PubMed Central; Publicly Available Content Database
subjects Bioengineering
Bone surgery
brachioradialis
Crosstalk
Elbow
electrode placement
Electrodes
Electromyography
Ergonomics
Flexors
Forearm
Guidelines
Humans
Investigations
Muscle function
Muscle, Skeletal - physiology
Muscles
Physiology
Reliability
Reproducibility of Results
Review
Sensors
surface electromyography
upper limb
title Electrode Size and Placement for Surface EMG Bipolar Detection from the Brachioradialis Muscle: A Scoping Review
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-09T17%3A10%3A59IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_doaj_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Electrode%20Size%20and%20Placement%20for%20Surface%20EMG%20Bipolar%20Detection%20from%20the%20Brachioradialis%20Muscle:%20A%20Scoping%20Review&rft.jtitle=Sensors%20(Basel,%20Switzerland)&rft.au=Merlo,%20Andrea&rft.date=2021-11-03&rft.volume=21&rft.issue=21&rft.spage=7322&rft.pages=7322-&rft.issn=1424-8220&rft.eissn=1424-8220&rft_id=info:doi/10.3390/s21217322&rft_dat=%3Cproquest_doaj_%3E2596066093%3C/proquest_doaj_%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c469t-7cda7f95b79f7d8c6b0d9c16080912a577e354905923fa7af1523ed3613e54833%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2596066093&rft_id=info:pmid/34770627&rfr_iscdi=true