Loading…

Statistical analysis of the removal of Chromium (VI) by Iron Oxide Nanoparticle (Fe3O4)

Investigation of the adsorption of Chromium (VI) on Fe3O4 is carried out using batch scale experiments according to statistical design using a software program minitab17 (Box-Behnken design). Experiments were carried out as per Box-Behnken design with four input parameters such as pH (2-8), initial...

Full description

Saved in:
Bibliographic Details
Published in:Journal of Engineering 2018-02, Vol.24 (2), p.62-79
Main Authors: Majid, Najwa Sabir, Naji, Dua Muhammad
Format: Article
Language:English
Citations: Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Investigation of the adsorption of Chromium (VI) on Fe3O4 is carried out using batch scale experiments according to statistical design using a software program minitab17 (Box-Behnken design). Experiments were carried out as per Box-Behnken design with four input parameters such as pH (2-8), initial concentration (50–150mg/L), adsorbent dosage (0.05–0.3 g) and time of adsorption (10–60min). The better conditions were showed at pH: 2; contact time: 60 min; chromium concentration: 50 mg/L and magnetite dosage: 0.3 g for maximum Chromium (VI) removal of (98.95%) with an error of 1.08%. The three models (Freundlich, Langmuir, and Temkin) were fitted to experimental data, Langmuir isotherm has better described the adsorption process. Whereas, the kinetics results of the adsorption process obeyed the pseudo-second-order. Keyword: Chromium (VI), Adsorption, Design of experiments, Iron Oxide Nanoparticle (Fe3O4).
ISSN:1726-4073
2520-3339
DOI:10.31026/j.eng.2018.02.05