Loading…

A prospective randomized study of different height of operation table for tracheal intubation with videolaryngoscopy in ramped position

Previous studies have reported that the ramped position provides a better laryngoscopic view, reduces tracheal intubation time, and increases the success rate of endotracheal intubation. However, the patient's head height changes while in the ramped position, which in turn changes the relative...

Full description

Saved in:
Bibliographic Details
Published in:BMC anesthesiology 2022-12, Vol.22 (1), p.378-378, Article 378
Main Authors: Kang, Dongho, Bae, Hong-Beom, Choi, Yun Ha, Bom, Joon-Suk, Kim, Joungmin
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Previous studies have reported that the ramped position provides a better laryngoscopic view, reduces tracheal intubation time, and increases the success rate of endotracheal intubation. However, the patient's head height changes while in the ramped position, which in turn changes the relative positions of the patient and intubator. Thus, making these changes may affect the efficiency of tracheal intubation; however, few studies have addressed this problem. This study analyzed intubation time and conditions during tracheal intubation using videolaryngoscope in the ramped position. This prospective study included 144 patients who were scheduled to receive general anesthesia for surgeries involving orotracheal intubation. The participants were randomly allocated to either the nipple or umbilical group according to the table height. Mask ventilation was assessed using the Warters grading scale. Tracheal intubation was performed using a McGrath MAC laryngoscope. The total intubation time, laryngoscopy time, tube insertion time, and difficulty of intubation (IDS score) were measured. The umbilical group had a significantly shorter laryngoscopy time (10 ± 3 vs. 16 ± 4 s), tube insertion time (18 ± 4 vs. 24 ± 6 s), and total intubation time (28 ± 5 vs. 40 ± 7 s) compared to the nipple group. No significant difference in the difficulty of mask ventilation was observed between the two groups. The IDS score was higher in the nipple than umbilical group. The lower (umbilical) table level reduced the intubation time and difficulty of videolaryngoscopy compared to the higher (nipple) table level. This study was registered at KCT0005987, 11/03/2021, Retrospectively registered.
ISSN:1471-2253
1471-2253
DOI:10.1186/s12871-022-01929-6