Feasibility and performance of a device for automatic self-detection of symptomatic acute coronary artery occlusion in outpatients with coronary artery disease: a multicentre observational study

Time delay between onset of symptoms and seeking medical attention is a major determinant of mortality and morbidity in patients with acute coronary artery occlusion. Response time might be reduced by reliable self-detection. We aimed to formally assess the proof-of-concept and accuracy of self-dete...

Full description

Saved in:
Bibliographic Details
Published in:The Lancet. Digital health 2019-06, Vol.1 (2), p.e90-e99
Main Authors: Van Heuverswyn, Frederic, De Buyzere, Marc, Coeman, Mathieu, De Pooter, Jan, Drieghe, Benny, Duytschaever, Mattias, Gevaert, Sofie, Kayaert, Peter, Vandekerckhove, Yves, Voet, Joeri, El Haddad, Milad, Gheeraert, Peter
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c422t-a8d42c1fcbf5c3b5f025c4d9a57c80c8d9b6bccd623cfc5ce9af469836a150c43
cites cdi_FETCH-LOGICAL-c422t-a8d42c1fcbf5c3b5f025c4d9a57c80c8d9b6bccd623cfc5ce9af469836a150c43
container_end_page e99
container_issue 2
container_start_page e90
container_title The Lancet. Digital health
container_volume 1
creator Van Heuverswyn, Frederic
De Buyzere, Marc
Coeman, Mathieu
De Pooter, Jan
Drieghe, Benny
Duytschaever, Mattias
Gevaert, Sofie
Kayaert, Peter
Vandekerckhove, Yves
Voet, Joeri
El Haddad, Milad
Gheeraert, Peter
description Time delay between onset of symptoms and seeking medical attention is a major determinant of mortality and morbidity in patients with acute coronary artery occlusion. Response time might be reduced by reliable self-detection. We aimed to formally assess the proof-of-concept and accuracy of self-detection of acute coronary artery occlusion by patients during daily life situations and during the very early stages of acute coronary artery occlusion. In this multicentre, observational study, we tested the operational feasibility, specificity, and sensitivity of our RELF method, a three-lead detection system with an automatic algorithm built into a mobile handheld device, for detection of acute coronary artery occlusion. Patients were recruited continuously by physician referrals from three Belgian hospitals until the desired sample size was achieved, had been discharged with planned elective percutaneous coronary intervention, and were able to use a smartphone; they were asked to perform random ambulatory self-recordings for at least 1 week. A similar self-recording was made before percutaneous coronary intervention and at 60 s of balloon occlusion. Patients were clinically followed up until 1 month after discharge. We quantitatively assessed the operational feasibility with an automated dichotomous quality check of self-recordings. Performance was assessed by analysing the receiver operator characteristics of the ST difference vector magnitude. This trial is registered with ClinicalTrials.gov, number NCT02983396. From Nov 18, 2016, to April 25, 2018, we enrolled 64 patients into the study, of whom 59 (92%) were eligible for self-applications. 58 (91%) of 64 (95% CI 81·0-95·6) patients were able to perform ambulatory self-recordings. Of all 5011 self-recordings, 4567 (91%) were automatically classified as successful within 1 min. In 65 balloon occlusions, 63 index tests at 60 s of occlusion in 55 patients were available. The mean specificity of daily life recordings was 0·96 (0·95-0·97). The mean false positive rate during daily life conditions was 4·19% (95% CI 3·29-5·10). The sensitivity for the target conditions was 0·87 (55 of 63; 95% CI 0·77-0·93) for acute coronary artery occlusion, 0·95 (54 of 57; 0·86-0·98) for acute coronary artery occlusion with electrocardiogram (ECG) changes, and 1·00 (35 of 35) for acute coronary artery occlusion with ECG changes and ST-segment elevation myocardial infarction criteria (STEMI). The index test was more sensitive to
doi_str_mv 10.1016/S2589-7500(19)30026-3
format article
fullrecord <record><control><sourceid>proquest_doaj_</sourceid><recordid>TN_cdi_doaj_primary_oai_doaj_org_article_baf891836b2443a5b958b2d97be09c6d</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><doaj_id>oai_doaj_org_article_baf891836b2443a5b958b2d97be09c6d</doaj_id><sourcerecordid>2470629230</sourcerecordid><originalsourceid>FETCH-LOGICAL-c422t-a8d42c1fcbf5c3b5f025c4d9a57c80c8d9b6bccd623cfc5ce9af469836a150c43</originalsourceid><addsrcrecordid>eNplksFu1DAQhiMEolXpI4B8LIcUx46TmBuqKK1UiQNwtuzxGFwlcbCdVvt6PBnObrtCQj7MaPzNP780U1VvG3rZ0Kb78I2JQda9oPSike85payr-Yvq9Fh--U9-Up2ndE8LxBre9_3r6oRzzsrjp9Wfa9TJGz_6vCN6tmTB6EKc9AxIgiOaWHzwJS9FotccJp09kISjqy1mhOzDvIFpNy3PvxrWjARCDLOORTZmLCEAjGvacF861rwUFuecyKPPv_6jrU_FGX4sDqZ1LKoFjcWSSRgf9DZVjyTl1e7eVK-cHhOeP8Wz6sf15-9XN_Xd1y-3V5_uamgZy7UebMugcWCcAG6Eo0xAa6UWPQwUBitNZwBsxzg4EIBSu7aTA-90Iyi0_Ky6PejaoO_VEv1U7KqgvdoXQvypincPIyqj3SCb0mpY23ItjBSDYVb2BqmEzhati4PWEsPvFVNWk0-A46hnDGtSrO1pxyTjtKDigEIMKUV0x9ENVds1qP01qG3VqpFqfw2Kl753TyNWM6E9dj3vnv8FxKK2yQ</addsrcrecordid><sourcetype>Open Website</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2470629230</pqid></control><display><type>article</type><title>Feasibility and performance of a device for automatic self-detection of symptomatic acute coronary artery occlusion in outpatients with coronary artery disease: a multicentre observational study</title><source>ScienceDirect Additional Titles</source><creator>Van Heuverswyn, Frederic ; De Buyzere, Marc ; Coeman, Mathieu ; De Pooter, Jan ; Drieghe, Benny ; Duytschaever, Mattias ; Gevaert, Sofie ; Kayaert, Peter ; Vandekerckhove, Yves ; Voet, Joeri ; El Haddad, Milad ; Gheeraert, Peter</creator><creatorcontrib>Van Heuverswyn, Frederic ; De Buyzere, Marc ; Coeman, Mathieu ; De Pooter, Jan ; Drieghe, Benny ; Duytschaever, Mattias ; Gevaert, Sofie ; Kayaert, Peter ; Vandekerckhove, Yves ; Voet, Joeri ; El Haddad, Milad ; Gheeraert, Peter</creatorcontrib><description>Time delay between onset of symptoms and seeking medical attention is a major determinant of mortality and morbidity in patients with acute coronary artery occlusion. Response time might be reduced by reliable self-detection. We aimed to formally assess the proof-of-concept and accuracy of self-detection of acute coronary artery occlusion by patients during daily life situations and during the very early stages of acute coronary artery occlusion. In this multicentre, observational study, we tested the operational feasibility, specificity, and sensitivity of our RELF method, a three-lead detection system with an automatic algorithm built into a mobile handheld device, for detection of acute coronary artery occlusion. Patients were recruited continuously by physician referrals from three Belgian hospitals until the desired sample size was achieved, had been discharged with planned elective percutaneous coronary intervention, and were able to use a smartphone; they were asked to perform random ambulatory self-recordings for at least 1 week. A similar self-recording was made before percutaneous coronary intervention and at 60 s of balloon occlusion. Patients were clinically followed up until 1 month after discharge. We quantitatively assessed the operational feasibility with an automated dichotomous quality check of self-recordings. Performance was assessed by analysing the receiver operator characteristics of the ST difference vector magnitude. This trial is registered with ClinicalTrials.gov, number NCT02983396. From Nov 18, 2016, to April 25, 2018, we enrolled 64 patients into the study, of whom 59 (92%) were eligible for self-applications. 58 (91%) of 64 (95% CI 81·0-95·6) patients were able to perform ambulatory self-recordings. Of all 5011 self-recordings, 4567 (91%) were automatically classified as successful within 1 min. In 65 balloon occlusions, 63 index tests at 60 s of occlusion in 55 patients were available. The mean specificity of daily life recordings was 0·96 (0·95-0·97). The mean false positive rate during daily life conditions was 4·19% (95% CI 3·29-5·10). The sensitivity for the target conditions was 0·87 (55 of 63; 95% CI 0·77-0·93) for acute coronary artery occlusion, 0·95 (54 of 57; 0·86-0·98) for acute coronary artery occlusion with electrocardiogram (ECG) changes, and 1·00 (35 of 35) for acute coronary artery occlusion with ECG changes and ST-segment elevation myocardial infarction criteria (STEMI). The index test was more sensitive to detect a 60 s balloon occlusion than the STEMI criteria on 12-lead ECG (87% vs 56%; p&lt;0·0001). The proportion of total variation in study estimates due to heterogeneity between patients (I ) was low (12·6%). The area under the receiver operator characteristics curve was 0·973 (95% CI 0·956-0·990) for acute coronary artery occlusion at different cutoff values of the magnitude of the ST difference vector. No patients died during the study. Self-recording with our RELF device is feasible for most patients with coronary artery disease. The sensitivity and specificity for automatic detection of the earliest phase of acute coronary artery occlusion support the concept of our RELF device for patient empowerment to reduce delay and increase Survival without overloading emergency services. Ghent University, Industrial Research Fund.</description><identifier>ISSN: 2589-7500</identifier><identifier>EISSN: 2589-7500</identifier><identifier>DOI: 10.1016/S2589-7500(19)30026-3</identifier><identifier>PMID: 33323233</identifier><language>eng</language><publisher>England: Elsevier</publisher><subject>Belgium ; Computers, Handheld ; Coronary Artery Disease ; Coronary Occlusion - diagnosis ; Coronary Occlusion - mortality ; Electrocardiography ; Feasibility Studies ; Female ; Humans ; Male ; Middle Aged ; Outpatients ; Percutaneous Coronary Intervention ; Sensitivity and Specificity ; ST Elevation Myocardial Infarction</subject><ispartof>The Lancet. Digital health, 2019-06, Vol.1 (2), p.e90-e99</ispartof><rights>Copyright © 2019 The Author(s). Published by Elsevier Ltd. This is an Open Access article under the CC BY 4.0 license. Published by Elsevier Ltd.. All rights reserved.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c422t-a8d42c1fcbf5c3b5f025c4d9a57c80c8d9b6bccd623cfc5ce9af469836a150c43</citedby><cites>FETCH-LOGICAL-c422t-a8d42c1fcbf5c3b5f025c4d9a57c80c8d9b6bccd623cfc5ce9af469836a150c43</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/33323233$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Van Heuverswyn, Frederic</creatorcontrib><creatorcontrib>De Buyzere, Marc</creatorcontrib><creatorcontrib>Coeman, Mathieu</creatorcontrib><creatorcontrib>De Pooter, Jan</creatorcontrib><creatorcontrib>Drieghe, Benny</creatorcontrib><creatorcontrib>Duytschaever, Mattias</creatorcontrib><creatorcontrib>Gevaert, Sofie</creatorcontrib><creatorcontrib>Kayaert, Peter</creatorcontrib><creatorcontrib>Vandekerckhove, Yves</creatorcontrib><creatorcontrib>Voet, Joeri</creatorcontrib><creatorcontrib>El Haddad, Milad</creatorcontrib><creatorcontrib>Gheeraert, Peter</creatorcontrib><title>Feasibility and performance of a device for automatic self-detection of symptomatic acute coronary artery occlusion in outpatients with coronary artery disease: a multicentre observational study</title><title>The Lancet. Digital health</title><addtitle>Lancet Digit Health</addtitle><description>Time delay between onset of symptoms and seeking medical attention is a major determinant of mortality and morbidity in patients with acute coronary artery occlusion. Response time might be reduced by reliable self-detection. We aimed to formally assess the proof-of-concept and accuracy of self-detection of acute coronary artery occlusion by patients during daily life situations and during the very early stages of acute coronary artery occlusion. In this multicentre, observational study, we tested the operational feasibility, specificity, and sensitivity of our RELF method, a three-lead detection system with an automatic algorithm built into a mobile handheld device, for detection of acute coronary artery occlusion. Patients were recruited continuously by physician referrals from three Belgian hospitals until the desired sample size was achieved, had been discharged with planned elective percutaneous coronary intervention, and were able to use a smartphone; they were asked to perform random ambulatory self-recordings for at least 1 week. A similar self-recording was made before percutaneous coronary intervention and at 60 s of balloon occlusion. Patients were clinically followed up until 1 month after discharge. We quantitatively assessed the operational feasibility with an automated dichotomous quality check of self-recordings. Performance was assessed by analysing the receiver operator characteristics of the ST difference vector magnitude. This trial is registered with ClinicalTrials.gov, number NCT02983396. From Nov 18, 2016, to April 25, 2018, we enrolled 64 patients into the study, of whom 59 (92%) were eligible for self-applications. 58 (91%) of 64 (95% CI 81·0-95·6) patients were able to perform ambulatory self-recordings. Of all 5011 self-recordings, 4567 (91%) were automatically classified as successful within 1 min. In 65 balloon occlusions, 63 index tests at 60 s of occlusion in 55 patients were available. The mean specificity of daily life recordings was 0·96 (0·95-0·97). The mean false positive rate during daily life conditions was 4·19% (95% CI 3·29-5·10). The sensitivity for the target conditions was 0·87 (55 of 63; 95% CI 0·77-0·93) for acute coronary artery occlusion, 0·95 (54 of 57; 0·86-0·98) for acute coronary artery occlusion with electrocardiogram (ECG) changes, and 1·00 (35 of 35) for acute coronary artery occlusion with ECG changes and ST-segment elevation myocardial infarction criteria (STEMI). The index test was more sensitive to detect a 60 s balloon occlusion than the STEMI criteria on 12-lead ECG (87% vs 56%; p&lt;0·0001). The proportion of total variation in study estimates due to heterogeneity between patients (I ) was low (12·6%). The area under the receiver operator characteristics curve was 0·973 (95% CI 0·956-0·990) for acute coronary artery occlusion at different cutoff values of the magnitude of the ST difference vector. No patients died during the study. Self-recording with our RELF device is feasible for most patients with coronary artery disease. The sensitivity and specificity for automatic detection of the earliest phase of acute coronary artery occlusion support the concept of our RELF device for patient empowerment to reduce delay and increase Survival without overloading emergency services. Ghent University, Industrial Research Fund.</description><subject>Belgium</subject><subject>Computers, Handheld</subject><subject>Coronary Artery Disease</subject><subject>Coronary Occlusion - diagnosis</subject><subject>Coronary Occlusion - mortality</subject><subject>Electrocardiography</subject><subject>Feasibility Studies</subject><subject>Female</subject><subject>Humans</subject><subject>Male</subject><subject>Middle Aged</subject><subject>Outpatients</subject><subject>Percutaneous Coronary Intervention</subject><subject>Sensitivity and Specificity</subject><subject>ST Elevation Myocardial Infarction</subject><issn>2589-7500</issn><issn>2589-7500</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2019</creationdate><recordtype>article</recordtype><sourceid>DOA</sourceid><recordid>eNplksFu1DAQhiMEolXpI4B8LIcUx46TmBuqKK1UiQNwtuzxGFwlcbCdVvt6PBnObrtCQj7MaPzNP780U1VvG3rZ0Kb78I2JQda9oPSike85payr-Yvq9Fh--U9-Up2ndE8LxBre9_3r6oRzzsrjp9Wfa9TJGz_6vCN6tmTB6EKc9AxIgiOaWHzwJS9FotccJp09kISjqy1mhOzDvIFpNy3PvxrWjARCDLOORTZmLCEAjGvacF861rwUFuecyKPPv_6jrU_FGX4sDqZ1LKoFjcWSSRgf9DZVjyTl1e7eVK-cHhOeP8Wz6sf15-9XN_Xd1y-3V5_uamgZy7UebMugcWCcAG6Eo0xAa6UWPQwUBitNZwBsxzg4EIBSu7aTA-90Iyi0_Ky6PejaoO_VEv1U7KqgvdoXQvypincPIyqj3SCb0mpY23ItjBSDYVb2BqmEzhati4PWEsPvFVNWk0-A46hnDGtSrO1pxyTjtKDigEIMKUV0x9ENVds1qP01qG3VqpFqfw2Kl753TyNWM6E9dj3vnv8FxKK2yQ</recordid><startdate>201906</startdate><enddate>201906</enddate><creator>Van Heuverswyn, Frederic</creator><creator>De Buyzere, Marc</creator><creator>Coeman, Mathieu</creator><creator>De Pooter, Jan</creator><creator>Drieghe, Benny</creator><creator>Duytschaever, Mattias</creator><creator>Gevaert, Sofie</creator><creator>Kayaert, Peter</creator><creator>Vandekerckhove, Yves</creator><creator>Voet, Joeri</creator><creator>El Haddad, Milad</creator><creator>Gheeraert, Peter</creator><general>Elsevier</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>DOA</scope></search><sort><creationdate>201906</creationdate><title>Feasibility and performance of a device for automatic self-detection of symptomatic acute coronary artery occlusion in outpatients with coronary artery disease: a multicentre observational study</title><author>Van Heuverswyn, Frederic ; De Buyzere, Marc ; Coeman, Mathieu ; De Pooter, Jan ; Drieghe, Benny ; Duytschaever, Mattias ; Gevaert, Sofie ; Kayaert, Peter ; Vandekerckhove, Yves ; Voet, Joeri ; El Haddad, Milad ; Gheeraert, Peter</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c422t-a8d42c1fcbf5c3b5f025c4d9a57c80c8d9b6bccd623cfc5ce9af469836a150c43</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2019</creationdate><topic>Belgium</topic><topic>Computers, Handheld</topic><topic>Coronary Artery Disease</topic><topic>Coronary Occlusion - diagnosis</topic><topic>Coronary Occlusion - mortality</topic><topic>Electrocardiography</topic><topic>Feasibility Studies</topic><topic>Female</topic><topic>Humans</topic><topic>Male</topic><topic>Middle Aged</topic><topic>Outpatients</topic><topic>Percutaneous Coronary Intervention</topic><topic>Sensitivity and Specificity</topic><topic>ST Elevation Myocardial Infarction</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Van Heuverswyn, Frederic</creatorcontrib><creatorcontrib>De Buyzere, Marc</creatorcontrib><creatorcontrib>Coeman, Mathieu</creatorcontrib><creatorcontrib>De Pooter, Jan</creatorcontrib><creatorcontrib>Drieghe, Benny</creatorcontrib><creatorcontrib>Duytschaever, Mattias</creatorcontrib><creatorcontrib>Gevaert, Sofie</creatorcontrib><creatorcontrib>Kayaert, Peter</creatorcontrib><creatorcontrib>Vandekerckhove, Yves</creatorcontrib><creatorcontrib>Voet, Joeri</creatorcontrib><creatorcontrib>El Haddad, Milad</creatorcontrib><creatorcontrib>Gheeraert, Peter</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>DOAJ Directory of Open Access Journals</collection><jtitle>The Lancet. Digital health</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Van Heuverswyn, Frederic</au><au>De Buyzere, Marc</au><au>Coeman, Mathieu</au><au>De Pooter, Jan</au><au>Drieghe, Benny</au><au>Duytschaever, Mattias</au><au>Gevaert, Sofie</au><au>Kayaert, Peter</au><au>Vandekerckhove, Yves</au><au>Voet, Joeri</au><au>El Haddad, Milad</au><au>Gheeraert, Peter</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Feasibility and performance of a device for automatic self-detection of symptomatic acute coronary artery occlusion in outpatients with coronary artery disease: a multicentre observational study</atitle><jtitle>The Lancet. Digital health</jtitle><addtitle>Lancet Digit Health</addtitle><date>2019-06</date><risdate>2019</risdate><volume>1</volume><issue>2</issue><spage>e90</spage><epage>e99</epage><pages>e90-e99</pages><issn>2589-7500</issn><eissn>2589-7500</eissn><abstract>Time delay between onset of symptoms and seeking medical attention is a major determinant of mortality and morbidity in patients with acute coronary artery occlusion. Response time might be reduced by reliable self-detection. We aimed to formally assess the proof-of-concept and accuracy of self-detection of acute coronary artery occlusion by patients during daily life situations and during the very early stages of acute coronary artery occlusion. In this multicentre, observational study, we tested the operational feasibility, specificity, and sensitivity of our RELF method, a three-lead detection system with an automatic algorithm built into a mobile handheld device, for detection of acute coronary artery occlusion. Patients were recruited continuously by physician referrals from three Belgian hospitals until the desired sample size was achieved, had been discharged with planned elective percutaneous coronary intervention, and were able to use a smartphone; they were asked to perform random ambulatory self-recordings for at least 1 week. A similar self-recording was made before percutaneous coronary intervention and at 60 s of balloon occlusion. Patients were clinically followed up until 1 month after discharge. We quantitatively assessed the operational feasibility with an automated dichotomous quality check of self-recordings. Performance was assessed by analysing the receiver operator characteristics of the ST difference vector magnitude. This trial is registered with ClinicalTrials.gov, number NCT02983396. From Nov 18, 2016, to April 25, 2018, we enrolled 64 patients into the study, of whom 59 (92%) were eligible for self-applications. 58 (91%) of 64 (95% CI 81·0-95·6) patients were able to perform ambulatory self-recordings. Of all 5011 self-recordings, 4567 (91%) were automatically classified as successful within 1 min. In 65 balloon occlusions, 63 index tests at 60 s of occlusion in 55 patients were available. The mean specificity of daily life recordings was 0·96 (0·95-0·97). The mean false positive rate during daily life conditions was 4·19% (95% CI 3·29-5·10). The sensitivity for the target conditions was 0·87 (55 of 63; 95% CI 0·77-0·93) for acute coronary artery occlusion, 0·95 (54 of 57; 0·86-0·98) for acute coronary artery occlusion with electrocardiogram (ECG) changes, and 1·00 (35 of 35) for acute coronary artery occlusion with ECG changes and ST-segment elevation myocardial infarction criteria (STEMI). The index test was more sensitive to detect a 60 s balloon occlusion than the STEMI criteria on 12-lead ECG (87% vs 56%; p&lt;0·0001). The proportion of total variation in study estimates due to heterogeneity between patients (I ) was low (12·6%). The area under the receiver operator characteristics curve was 0·973 (95% CI 0·956-0·990) for acute coronary artery occlusion at different cutoff values of the magnitude of the ST difference vector. No patients died during the study. Self-recording with our RELF device is feasible for most patients with coronary artery disease. The sensitivity and specificity for automatic detection of the earliest phase of acute coronary artery occlusion support the concept of our RELF device for patient empowerment to reduce delay and increase Survival without overloading emergency services. Ghent University, Industrial Research Fund.</abstract><cop>England</cop><pub>Elsevier</pub><pmid>33323233</pmid><doi>10.1016/S2589-7500(19)30026-3</doi><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 2589-7500
ispartof The Lancet. Digital health, 2019-06, Vol.1 (2), p.e90-e99
issn 2589-7500
2589-7500
language eng
recordid cdi_doaj_primary_oai_doaj_org_article_baf891836b2443a5b958b2d97be09c6d
source ScienceDirect Additional Titles
subjects Belgium
Computers, Handheld
Coronary Artery Disease
Coronary Occlusion - diagnosis
Coronary Occlusion - mortality
Electrocardiography
Feasibility Studies
Female
Humans
Male
Middle Aged
Outpatients
Percutaneous Coronary Intervention
Sensitivity and Specificity
ST Elevation Myocardial Infarction
title Feasibility and performance of a device for automatic self-detection of symptomatic acute coronary artery occlusion in outpatients with coronary artery disease: a multicentre observational study
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-29T15%3A33%3A20IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_doaj_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Feasibility%20and%20performance%20of%20a%20device%20for%20automatic%20self-detection%20of%20symptomatic%20acute%20coronary%20artery%20occlusion%20in%20outpatients%20with%20coronary%20artery%20disease:%20a%20multicentre%20observational%20study&rft.jtitle=The%20Lancet.%20Digital%20health&rft.au=Van%20Heuverswyn,%20Frederic&rft.date=2019-06&rft.volume=1&rft.issue=2&rft.spage=e90&rft.epage=e99&rft.pages=e90-e99&rft.issn=2589-7500&rft.eissn=2589-7500&rft_id=info:doi/10.1016/S2589-7500(19)30026-3&rft_dat=%3Cproquest_doaj_%3E2470629230%3C/proquest_doaj_%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c422t-a8d42c1fcbf5c3b5f025c4d9a57c80c8d9b6bccd623cfc5ce9af469836a150c43%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2470629230&rft_id=info:pmid/33323233&rfr_iscdi=true