Loading…
Body Position Affects Capillary Blood Flow Regulation Measured with Wearable Blood Flow Sensors
In this study we demonstrate what kind of relative alterations can be expected in average perfusion and blood flow oscillations during postural changes being measured in the skin of limbs and on the brow of the forehead by wearable laser Doppler flowmetry (LDF) sensors. The aims of the study were to...
Saved in:
Published in: | Diagnostics (Basel) 2021-03, Vol.11 (3), p.436 |
---|---|
Main Authors: | , , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c499t-eddd94031711591465995a355ce3c7408e85b69a54a05d91432bb71f1fea8fc93 |
---|---|
cites | cdi_FETCH-LOGICAL-c499t-eddd94031711591465995a355ce3c7408e85b69a54a05d91432bb71f1fea8fc93 |
container_end_page | |
container_issue | 3 |
container_start_page | 436 |
container_title | Diagnostics (Basel) |
container_volume | 11 |
creator | Fedorovich, Andrey A Loktionova, Yulia I Zharkikh, Elena V Mikhailova, Maria A Popova, Julia A Suvorov, Alexander V Zherebtsov, Evgeny A |
description | In this study we demonstrate what kind of relative alterations can be expected in average perfusion and blood flow oscillations during postural changes being measured in the skin of limbs and on the brow of the forehead by wearable laser Doppler flowmetry (LDF) sensors. The aims of the study were to evaluate the dynamics of cutaneous blood perfusion and the regulatory mechanisms of blood microcirculation in the areas of interest, and evaluate the possible significance of those effects for the diagnostics based on blood perfusion monitoring. The study involved 10 conditionally healthy volunteers (44 ± 12 years). Wearable laser Doppler flowmetry monitors were fixed at six points on the body: two devices were fixed on the forehead, on the brow; two were on the distal thirds of the right and left forearms; and two were on the distal thirds of the right and left lower legs. The protocol was used to record three body positions on the tilt table for orthostatic test for each volunteer in the following sequence: (a) supine body position; (b) upright body position (+75°); (c) tilted with the feet elevated above the head and the inclination of body axis of 15° (-15°, Trendelenburg position). Skin blood perfusion was recorded for 10 min in each body position, followed by the amplitude-frequency analysis of the registered signals using wavelet decomposition. The measurements were supplemented with the blood pressure and heart rate for every body position analysed. The results identified a statistically significant transformation in microcirculation parameters of the average level of skin blood perfusion and oscillations of amplitudes of neurogenic, myogenic and cardiac sensors caused by the postural changes. In paper, we present the analysis of microcirculation in the skin of the forehead, which for the first time was carried out in various positions of the body. The area is supplied by the internal carotid artery system and can be of particular interest for evaluation of the sufficiency of blood supply for the brain. |
doi_str_mv | 10.3390/diagnostics11030436 |
format | article |
fullrecord | <record><control><sourceid>proquest_doaj_</sourceid><recordid>TN_cdi_doaj_primary_oai_doaj_org_article_bafdc5f2acab4d029df27e66eaa2fb08</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><doaj_id>oai_doaj_org_article_bafdc5f2acab4d029df27e66eaa2fb08</doaj_id><sourcerecordid>2499191950</sourcerecordid><originalsourceid>FETCH-LOGICAL-c499t-eddd94031711591465995a355ce3c7408e85b69a54a05d91432bb71f1fea8fc93</originalsourceid><addsrcrecordid>eNptkl1rFDEUhoMottT-AkEGvPFmNR-TmeRGaJdWCxXFD7wMZ5KTbZbsZE1mLP33pt1atmLORcLJc15O3hxCXjL6VghN37kAqzGVKdjCGBW0Fd0TcshpLxdty9TTvfMBOS5lTevSTCgun5MDIRTtBFeHxJwmd9N8SSVMIY3Nifdop9IsYRtihHzTnMaUXHMe03XzFVdzhDvuE0KZM7rmOkxXzU-EDEPEffgbjiXl8oI88xALHt_vR-TH-dn35cfF5ecPF8uTy4VttZ4W6JzTLRWsZ0xq1nZSawlCSovC9i1VqOTQaZAtUOkqIPgw9Mwzj6C81eKIXOx0XYK12eawqc2bBMHcJVJeGcjVrYhmAO-s9BwsDK2jXDvPe-w6BOB-oKpqvd9pbedhg87iOGWIj0Qf34zhyqzSb9NrrZW4FXhzL5DTrxnLZDahWKyGjpjmYrikSna9ZLyir_9B12nOY7XK8OoMqyFppcSOsjmVktE_NMOouZ0H8595qFWv9t_xUPP398UfdZi1FQ</addsrcrecordid><sourcetype>Open Website</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2499191950</pqid></control><display><type>article</type><title>Body Position Affects Capillary Blood Flow Regulation Measured with Wearable Blood Flow Sensors</title><source>Publicly Available Content Database</source><source>PubMed Central</source><creator>Fedorovich, Andrey A ; Loktionova, Yulia I ; Zharkikh, Elena V ; Mikhailova, Maria A ; Popova, Julia A ; Suvorov, Alexander V ; Zherebtsov, Evgeny A</creator><creatorcontrib>Fedorovich, Andrey A ; Loktionova, Yulia I ; Zharkikh, Elena V ; Mikhailova, Maria A ; Popova, Julia A ; Suvorov, Alexander V ; Zherebtsov, Evgeny A</creatorcontrib><description>In this study we demonstrate what kind of relative alterations can be expected in average perfusion and blood flow oscillations during postural changes being measured in the skin of limbs and on the brow of the forehead by wearable laser Doppler flowmetry (LDF) sensors. The aims of the study were to evaluate the dynamics of cutaneous blood perfusion and the regulatory mechanisms of blood microcirculation in the areas of interest, and evaluate the possible significance of those effects for the diagnostics based on blood perfusion monitoring. The study involved 10 conditionally healthy volunteers (44 ± 12 years). Wearable laser Doppler flowmetry monitors were fixed at six points on the body: two devices were fixed on the forehead, on the brow; two were on the distal thirds of the right and left forearms; and two were on the distal thirds of the right and left lower legs. The protocol was used to record three body positions on the tilt table for orthostatic test for each volunteer in the following sequence: (a) supine body position; (b) upright body position (+75°); (c) tilted with the feet elevated above the head and the inclination of body axis of 15° (-15°, Trendelenburg position). Skin blood perfusion was recorded for 10 min in each body position, followed by the amplitude-frequency analysis of the registered signals using wavelet decomposition. The measurements were supplemented with the blood pressure and heart rate for every body position analysed. The results identified a statistically significant transformation in microcirculation parameters of the average level of skin blood perfusion and oscillations of amplitudes of neurogenic, myogenic and cardiac sensors caused by the postural changes. In paper, we present the analysis of microcirculation in the skin of the forehead, which for the first time was carried out in various positions of the body. The area is supplied by the internal carotid artery system and can be of particular interest for evaluation of the sufficiency of blood supply for the brain.</description><identifier>ISSN: 2075-4418</identifier><identifier>EISSN: 2075-4418</identifier><identifier>DOI: 10.3390/diagnostics11030436</identifier><identifier>PMID: 33806328</identifier><language>eng</language><publisher>Switzerland: MDPI AG</publisher><subject>blood perfusion ; Blood pressure ; body position ; Cardiovascular system ; Heart rate ; laser Doppler flowmetry ; Lasers ; ortostatic test ; Physiology ; postural changes ; Posture ; Sensors ; Skin ; wearable blood flow sensors</subject><ispartof>Diagnostics (Basel), 2021-03, Vol.11 (3), p.436</ispartof><rights>2021. This work is licensed under http://creativecommons.org/licenses/by/3.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.</rights><rights>2021 by the authors. 2021</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c499t-eddd94031711591465995a355ce3c7408e85b69a54a05d91432bb71f1fea8fc93</citedby><cites>FETCH-LOGICAL-c499t-eddd94031711591465995a355ce3c7408e85b69a54a05d91432bb71f1fea8fc93</cites><orcidid>0000-0002-6628-1285 ; 0000-0001-5735-3366 ; 0000-0002-3635-1430 ; 0000-0003-4706-8064 ; 0000-0001-5140-568X</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.proquest.com/docview/2499191950/fulltextPDF?pq-origsite=primo$$EPDF$$P50$$Gproquest$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.proquest.com/docview/2499191950?pq-origsite=primo$$EHTML$$P50$$Gproquest$$Hfree_for_read</linktohtml><link.rule.ids>230,314,727,780,784,885,25753,27924,27925,37012,37013,44590,53791,53793,75126</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/33806328$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Fedorovich, Andrey A</creatorcontrib><creatorcontrib>Loktionova, Yulia I</creatorcontrib><creatorcontrib>Zharkikh, Elena V</creatorcontrib><creatorcontrib>Mikhailova, Maria A</creatorcontrib><creatorcontrib>Popova, Julia A</creatorcontrib><creatorcontrib>Suvorov, Alexander V</creatorcontrib><creatorcontrib>Zherebtsov, Evgeny A</creatorcontrib><title>Body Position Affects Capillary Blood Flow Regulation Measured with Wearable Blood Flow Sensors</title><title>Diagnostics (Basel)</title><addtitle>Diagnostics (Basel)</addtitle><description>In this study we demonstrate what kind of relative alterations can be expected in average perfusion and blood flow oscillations during postural changes being measured in the skin of limbs and on the brow of the forehead by wearable laser Doppler flowmetry (LDF) sensors. The aims of the study were to evaluate the dynamics of cutaneous blood perfusion and the regulatory mechanisms of blood microcirculation in the areas of interest, and evaluate the possible significance of those effects for the diagnostics based on blood perfusion monitoring. The study involved 10 conditionally healthy volunteers (44 ± 12 years). Wearable laser Doppler flowmetry monitors were fixed at six points on the body: two devices were fixed on the forehead, on the brow; two were on the distal thirds of the right and left forearms; and two were on the distal thirds of the right and left lower legs. The protocol was used to record three body positions on the tilt table for orthostatic test for each volunteer in the following sequence: (a) supine body position; (b) upright body position (+75°); (c) tilted with the feet elevated above the head and the inclination of body axis of 15° (-15°, Trendelenburg position). Skin blood perfusion was recorded for 10 min in each body position, followed by the amplitude-frequency analysis of the registered signals using wavelet decomposition. The measurements were supplemented with the blood pressure and heart rate for every body position analysed. The results identified a statistically significant transformation in microcirculation parameters of the average level of skin blood perfusion and oscillations of amplitudes of neurogenic, myogenic and cardiac sensors caused by the postural changes. In paper, we present the analysis of microcirculation in the skin of the forehead, which for the first time was carried out in various positions of the body. The area is supplied by the internal carotid artery system and can be of particular interest for evaluation of the sufficiency of blood supply for the brain.</description><subject>blood perfusion</subject><subject>Blood pressure</subject><subject>body position</subject><subject>Cardiovascular system</subject><subject>Heart rate</subject><subject>laser Doppler flowmetry</subject><subject>Lasers</subject><subject>ortostatic test</subject><subject>Physiology</subject><subject>postural changes</subject><subject>Posture</subject><subject>Sensors</subject><subject>Skin</subject><subject>wearable blood flow sensors</subject><issn>2075-4418</issn><issn>2075-4418</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2021</creationdate><recordtype>article</recordtype><sourceid>PIMPY</sourceid><sourceid>DOA</sourceid><recordid>eNptkl1rFDEUhoMottT-AkEGvPFmNR-TmeRGaJdWCxXFD7wMZ5KTbZbsZE1mLP33pt1atmLORcLJc15O3hxCXjL6VghN37kAqzGVKdjCGBW0Fd0TcshpLxdty9TTvfMBOS5lTevSTCgun5MDIRTtBFeHxJwmd9N8SSVMIY3Nifdop9IsYRtihHzTnMaUXHMe03XzFVdzhDvuE0KZM7rmOkxXzU-EDEPEffgbjiXl8oI88xALHt_vR-TH-dn35cfF5ecPF8uTy4VttZ4W6JzTLRWsZ0xq1nZSawlCSovC9i1VqOTQaZAtUOkqIPgw9Mwzj6C81eKIXOx0XYK12eawqc2bBMHcJVJeGcjVrYhmAO-s9BwsDK2jXDvPe-w6BOB-oKpqvd9pbedhg87iOGWIj0Qf34zhyqzSb9NrrZW4FXhzL5DTrxnLZDahWKyGjpjmYrikSna9ZLyir_9B12nOY7XK8OoMqyFppcSOsjmVktE_NMOouZ0H8595qFWv9t_xUPP398UfdZi1FQ</recordid><startdate>20210304</startdate><enddate>20210304</enddate><creator>Fedorovich, Andrey A</creator><creator>Loktionova, Yulia I</creator><creator>Zharkikh, Elena V</creator><creator>Mikhailova, Maria A</creator><creator>Popova, Julia A</creator><creator>Suvorov, Alexander V</creator><creator>Zherebtsov, Evgeny A</creator><general>MDPI AG</general><general>MDPI</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>3V.</scope><scope>7XB</scope><scope>8FK</scope><scope>8G5</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>GNUQQ</scope><scope>GUQSH</scope><scope>M2O</scope><scope>MBDVC</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>Q9U</scope><scope>7X8</scope><scope>5PM</scope><scope>DOA</scope><orcidid>https://orcid.org/0000-0002-6628-1285</orcidid><orcidid>https://orcid.org/0000-0001-5735-3366</orcidid><orcidid>https://orcid.org/0000-0002-3635-1430</orcidid><orcidid>https://orcid.org/0000-0003-4706-8064</orcidid><orcidid>https://orcid.org/0000-0001-5140-568X</orcidid></search><sort><creationdate>20210304</creationdate><title>Body Position Affects Capillary Blood Flow Regulation Measured with Wearable Blood Flow Sensors</title><author>Fedorovich, Andrey A ; Loktionova, Yulia I ; Zharkikh, Elena V ; Mikhailova, Maria A ; Popova, Julia A ; Suvorov, Alexander V ; Zherebtsov, Evgeny A</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c499t-eddd94031711591465995a355ce3c7408e85b69a54a05d91432bb71f1fea8fc93</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2021</creationdate><topic>blood perfusion</topic><topic>Blood pressure</topic><topic>body position</topic><topic>Cardiovascular system</topic><topic>Heart rate</topic><topic>laser Doppler flowmetry</topic><topic>Lasers</topic><topic>ortostatic test</topic><topic>Physiology</topic><topic>postural changes</topic><topic>Posture</topic><topic>Sensors</topic><topic>Skin</topic><topic>wearable blood flow sensors</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Fedorovich, Andrey A</creatorcontrib><creatorcontrib>Loktionova, Yulia I</creatorcontrib><creatorcontrib>Zharkikh, Elena V</creatorcontrib><creatorcontrib>Mikhailova, Maria A</creatorcontrib><creatorcontrib>Popova, Julia A</creatorcontrib><creatorcontrib>Suvorov, Alexander V</creatorcontrib><creatorcontrib>Zherebtsov, Evgeny A</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>ProQuest Central (Corporate)</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>Research Library (Alumni Edition)</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest Central UK/Ireland</collection><collection>ProQuest Central Essentials</collection><collection>ProQuest Central</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central Korea</collection><collection>ProQuest Central Student</collection><collection>Research Library Prep</collection><collection>Research Library</collection><collection>Research Library (Corporate)</collection><collection>Publicly Available Content Database</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>ProQuest Central Basic</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><collection>DOAJ Directory of Open Access Journals</collection><jtitle>Diagnostics (Basel)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Fedorovich, Andrey A</au><au>Loktionova, Yulia I</au><au>Zharkikh, Elena V</au><au>Mikhailova, Maria A</au><au>Popova, Julia A</au><au>Suvorov, Alexander V</au><au>Zherebtsov, Evgeny A</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Body Position Affects Capillary Blood Flow Regulation Measured with Wearable Blood Flow Sensors</atitle><jtitle>Diagnostics (Basel)</jtitle><addtitle>Diagnostics (Basel)</addtitle><date>2021-03-04</date><risdate>2021</risdate><volume>11</volume><issue>3</issue><spage>436</spage><pages>436-</pages><issn>2075-4418</issn><eissn>2075-4418</eissn><abstract>In this study we demonstrate what kind of relative alterations can be expected in average perfusion and blood flow oscillations during postural changes being measured in the skin of limbs and on the brow of the forehead by wearable laser Doppler flowmetry (LDF) sensors. The aims of the study were to evaluate the dynamics of cutaneous blood perfusion and the regulatory mechanisms of blood microcirculation in the areas of interest, and evaluate the possible significance of those effects for the diagnostics based on blood perfusion monitoring. The study involved 10 conditionally healthy volunteers (44 ± 12 years). Wearable laser Doppler flowmetry monitors were fixed at six points on the body: two devices were fixed on the forehead, on the brow; two were on the distal thirds of the right and left forearms; and two were on the distal thirds of the right and left lower legs. The protocol was used to record three body positions on the tilt table for orthostatic test for each volunteer in the following sequence: (a) supine body position; (b) upright body position (+75°); (c) tilted with the feet elevated above the head and the inclination of body axis of 15° (-15°, Trendelenburg position). Skin blood perfusion was recorded for 10 min in each body position, followed by the amplitude-frequency analysis of the registered signals using wavelet decomposition. The measurements were supplemented with the blood pressure and heart rate for every body position analysed. The results identified a statistically significant transformation in microcirculation parameters of the average level of skin blood perfusion and oscillations of amplitudes of neurogenic, myogenic and cardiac sensors caused by the postural changes. In paper, we present the analysis of microcirculation in the skin of the forehead, which for the first time was carried out in various positions of the body. The area is supplied by the internal carotid artery system and can be of particular interest for evaluation of the sufficiency of blood supply for the brain.</abstract><cop>Switzerland</cop><pub>MDPI AG</pub><pmid>33806328</pmid><doi>10.3390/diagnostics11030436</doi><orcidid>https://orcid.org/0000-0002-6628-1285</orcidid><orcidid>https://orcid.org/0000-0001-5735-3366</orcidid><orcidid>https://orcid.org/0000-0002-3635-1430</orcidid><orcidid>https://orcid.org/0000-0003-4706-8064</orcidid><orcidid>https://orcid.org/0000-0001-5140-568X</orcidid><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 2075-4418 |
ispartof | Diagnostics (Basel), 2021-03, Vol.11 (3), p.436 |
issn | 2075-4418 2075-4418 |
language | eng |
recordid | cdi_doaj_primary_oai_doaj_org_article_bafdc5f2acab4d029df27e66eaa2fb08 |
source | Publicly Available Content Database; PubMed Central |
subjects | blood perfusion Blood pressure body position Cardiovascular system Heart rate laser Doppler flowmetry Lasers ortostatic test Physiology postural changes Posture Sensors Skin wearable blood flow sensors |
title | Body Position Affects Capillary Blood Flow Regulation Measured with Wearable Blood Flow Sensors |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-03T08%3A12%3A16IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_doaj_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Body%20Position%20Affects%20Capillary%20Blood%20Flow%20Regulation%20Measured%20with%20Wearable%20Blood%20Flow%20Sensors&rft.jtitle=Diagnostics%20(Basel)&rft.au=Fedorovich,%20Andrey%20A&rft.date=2021-03-04&rft.volume=11&rft.issue=3&rft.spage=436&rft.pages=436-&rft.issn=2075-4418&rft.eissn=2075-4418&rft_id=info:doi/10.3390/diagnostics11030436&rft_dat=%3Cproquest_doaj_%3E2499191950%3C/proquest_doaj_%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c499t-eddd94031711591465995a355ce3c7408e85b69a54a05d91432bb71f1fea8fc93%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2499191950&rft_id=info:pmid/33806328&rfr_iscdi=true |