Loading…

Estimation of anisotropic permeability in trabecular bone based on microCT imaging and pore-scale fluid dynamics simulations

In this paper, a comprehensive framework is proposed to estimate the anisotropic permeability matrix in trabecular bone specimens based on micro-computed tomography (microCT) imaging combined with pore-scale fluid dynamics simulations. Two essential steps in the proposed methodology are the selectio...

Full description

Saved in:
Bibliographic Details
Published in:Bone Reports 2017-06, Vol.6 (C), p.129-139
Main Authors: Daish, C, Blanchard, R, Gulati, K, Losic, D, Findlay, D, Harvie, D J E, Pivonka, P
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c3832-f770eb291a257eee3a6b3aed01d81f9f8b319f67bedf6bb7aa30c4c8c23df9933
cites cdi_FETCH-LOGICAL-c3832-f770eb291a257eee3a6b3aed01d81f9f8b319f67bedf6bb7aa30c4c8c23df9933
container_end_page 139
container_issue C
container_start_page 129
container_title Bone Reports
container_volume 6
creator Daish, C
Blanchard, R
Gulati, K
Losic, D
Findlay, D
Harvie, D J E
Pivonka, P
description In this paper, a comprehensive framework is proposed to estimate the anisotropic permeability matrix in trabecular bone specimens based on micro-computed tomography (microCT) imaging combined with pore-scale fluid dynamics simulations. Two essential steps in the proposed methodology are the selection of (i) a representative volume element (RVE) for calculation of trabecular bone permeability and (ii) a converged mesh for accurate calculation of pore fluid flow properties. Accurate estimates of trabecular bone porosities are obtained using a microCT image resolution of approximately 10 μm. We show that a trabecular bone RVE in the order of 2 × 2 × 2 mm is most suitable. Mesh convergence studies show that accurate fluid flow properties are obtained for a mesh size above 125,000 elements. Volume averaging of the pore-scale fluid flow properties allows calculation of the apparent permeability matrix of trabecular bone specimens. For the four specimens chosen, our numerical results show that the so obtained permeability coefficients are in excellent agreement with previously reported experimental data for both human and bovine trabecular bone samples. We also identified that bone samples taken from long bones generally exhibit a larger permeability in the longitudinal direction. The fact that all coefficients of the permeability matrix were different from zero indicates that bone samples are generally not harvested in the principal flow directions. The full permeability matrix was diagonalized by calculating the eigenvalues, while the eigenvectors showed how strongly the bone sample's orientations deviated from the principal flow directions. Porosity values of the four bone specimens range from 0.83 to 0.86, with a low standard deviation of ± 0.016, principal permeability values range from 0.22 to 1.45 ⋅ 10  m , with a high standard deviation of ± 0.33. Also, the anisotropic ratio ranged from 0.27 to 0.83, with high standard deviation. These results indicate that while the four specimens are quite similar in terms of average porosity, large variability exists with respect to permeability and specimen anisotropy. The utilized computational approach compares well with semi-analytical models based on homogenization theory. This methodology can be applied in bone tissue engineering applications for generating accurate pore morphologies of bone replacement materials and to consistently select similar bone specimens in bone bioreactor studies.
doi_str_mv 10.1016/j.bonr.2016.12.002
format article
fullrecord <record><control><sourceid>proquest_doaj_</sourceid><recordid>TN_cdi_doaj_primary_oai_doaj_org_article_bd98a13dfdb74608803e044d64726f01</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><doaj_id>oai_doaj_org_article_bd98a13dfdb74608803e044d64726f01</doaj_id><sourcerecordid>1894518839</sourcerecordid><originalsourceid>FETCH-LOGICAL-c3832-f770eb291a257eee3a6b3aed01d81f9f8b319f67bedf6bb7aa30c4c8c23df9933</originalsourceid><addsrcrecordid>eNpVkk1r3DAQhk1paUKaP9BD0bEXu_rwh3QplCVtA4Fe0rMYSaOtFtvaSnZhoT8-cjcNyUmDNO_zDqO3qt4z2jDK-k-HxsQ5NbzUDeMNpfxVdclFx2smB_76WX1RXed8oJSyTrWDUm-rCy7bnoueXVZ_b_ISJlhCnEn0BOaQ45LiMVhyxDQhmDCG5UTCTJYEBu06QiLFGomBjI4U3RRsirt7Ujj7MO8LxJFjTFhnCyMSP67BEXeaoTRmksNUGJthfle98TBmvH48r6qfX2_ud9_rux_fbndf7morpOC1HwaKhisGvBsQUUBvBKCjzEnmlZdGMOX7waDzvTEDgKC2tdJy4bxSQlxVt2eui3DQx1QGTScdIeh_FzHtNaQl2BG1cUoCKzpnhranUlKBtG1d3w6895QV1ucz67iaCZ3FuexlfAF9-TKHX3of_-iupZKJDfDxEZDi7xXzoqeQLY4jzBjXrJlUbcekFKq08nNr2W_OCf2TDaN6S4E-6C0FekuBZlyXFBTRh-cDPkn-_7l4AN92spc</addsrcrecordid><sourcetype>Open Website</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1894518839</pqid></control><display><type>article</type><title>Estimation of anisotropic permeability in trabecular bone based on microCT imaging and pore-scale fluid dynamics simulations</title><source>ScienceDirect®</source><source>PubMed Central</source><creator>Daish, C ; Blanchard, R ; Gulati, K ; Losic, D ; Findlay, D ; Harvie, D J E ; Pivonka, P</creator><creatorcontrib>Daish, C ; Blanchard, R ; Gulati, K ; Losic, D ; Findlay, D ; Harvie, D J E ; Pivonka, P</creatorcontrib><description>In this paper, a comprehensive framework is proposed to estimate the anisotropic permeability matrix in trabecular bone specimens based on micro-computed tomography (microCT) imaging combined with pore-scale fluid dynamics simulations. Two essential steps in the proposed methodology are the selection of (i) a representative volume element (RVE) for calculation of trabecular bone permeability and (ii) a converged mesh for accurate calculation of pore fluid flow properties. Accurate estimates of trabecular bone porosities are obtained using a microCT image resolution of approximately 10 μm. We show that a trabecular bone RVE in the order of 2 × 2 × 2 mm is most suitable. Mesh convergence studies show that accurate fluid flow properties are obtained for a mesh size above 125,000 elements. Volume averaging of the pore-scale fluid flow properties allows calculation of the apparent permeability matrix of trabecular bone specimens. For the four specimens chosen, our numerical results show that the so obtained permeability coefficients are in excellent agreement with previously reported experimental data for both human and bovine trabecular bone samples. We also identified that bone samples taken from long bones generally exhibit a larger permeability in the longitudinal direction. The fact that all coefficients of the permeability matrix were different from zero indicates that bone samples are generally not harvested in the principal flow directions. The full permeability matrix was diagonalized by calculating the eigenvalues, while the eigenvectors showed how strongly the bone sample's orientations deviated from the principal flow directions. Porosity values of the four bone specimens range from 0.83 to 0.86, with a low standard deviation of ± 0.016, principal permeability values range from 0.22 to 1.45 ⋅ 10  m , with a high standard deviation of ± 0.33. Also, the anisotropic ratio ranged from 0.27 to 0.83, with high standard deviation. These results indicate that while the four specimens are quite similar in terms of average porosity, large variability exists with respect to permeability and specimen anisotropy. The utilized computational approach compares well with semi-analytical models based on homogenization theory. This methodology can be applied in bone tissue engineering applications for generating accurate pore morphologies of bone replacement materials and to consistently select similar bone specimens in bone bioreactor studies.</description><identifier>ISSN: 2352-1872</identifier><identifier>EISSN: 2352-1872</identifier><identifier>DOI: 10.1016/j.bonr.2016.12.002</identifier><identifier>PMID: 28462361</identifier><language>eng</language><publisher>United States: Elsevier</publisher><subject>Anisotropic permeability ; Darcy's law ; Fluid dynamics ; MicroCT ; Trabecular bone</subject><ispartof>Bone Reports, 2017-06, Vol.6 (C), p.129-139</ispartof><rights>2016 The Authors 2016</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c3832-f770eb291a257eee3a6b3aed01d81f9f8b319f67bedf6bb7aa30c4c8c23df9933</citedby><cites>FETCH-LOGICAL-c3832-f770eb291a257eee3a6b3aed01d81f9f8b319f67bedf6bb7aa30c4c8c23df9933</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC5408131/pdf/$$EPDF$$P50$$Gpubmedcentral$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC5408131/$$EHTML$$P50$$Gpubmedcentral$$Hfree_for_read</linktohtml><link.rule.ids>230,314,727,780,784,885,27923,27924,53790,53792</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/28462361$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Daish, C</creatorcontrib><creatorcontrib>Blanchard, R</creatorcontrib><creatorcontrib>Gulati, K</creatorcontrib><creatorcontrib>Losic, D</creatorcontrib><creatorcontrib>Findlay, D</creatorcontrib><creatorcontrib>Harvie, D J E</creatorcontrib><creatorcontrib>Pivonka, P</creatorcontrib><title>Estimation of anisotropic permeability in trabecular bone based on microCT imaging and pore-scale fluid dynamics simulations</title><title>Bone Reports</title><addtitle>Bone Rep</addtitle><description>In this paper, a comprehensive framework is proposed to estimate the anisotropic permeability matrix in trabecular bone specimens based on micro-computed tomography (microCT) imaging combined with pore-scale fluid dynamics simulations. Two essential steps in the proposed methodology are the selection of (i) a representative volume element (RVE) for calculation of trabecular bone permeability and (ii) a converged mesh for accurate calculation of pore fluid flow properties. Accurate estimates of trabecular bone porosities are obtained using a microCT image resolution of approximately 10 μm. We show that a trabecular bone RVE in the order of 2 × 2 × 2 mm is most suitable. Mesh convergence studies show that accurate fluid flow properties are obtained for a mesh size above 125,000 elements. Volume averaging of the pore-scale fluid flow properties allows calculation of the apparent permeability matrix of trabecular bone specimens. For the four specimens chosen, our numerical results show that the so obtained permeability coefficients are in excellent agreement with previously reported experimental data for both human and bovine trabecular bone samples. We also identified that bone samples taken from long bones generally exhibit a larger permeability in the longitudinal direction. The fact that all coefficients of the permeability matrix were different from zero indicates that bone samples are generally not harvested in the principal flow directions. The full permeability matrix was diagonalized by calculating the eigenvalues, while the eigenvectors showed how strongly the bone sample's orientations deviated from the principal flow directions. Porosity values of the four bone specimens range from 0.83 to 0.86, with a low standard deviation of ± 0.016, principal permeability values range from 0.22 to 1.45 ⋅ 10  m , with a high standard deviation of ± 0.33. Also, the anisotropic ratio ranged from 0.27 to 0.83, with high standard deviation. These results indicate that while the four specimens are quite similar in terms of average porosity, large variability exists with respect to permeability and specimen anisotropy. The utilized computational approach compares well with semi-analytical models based on homogenization theory. This methodology can be applied in bone tissue engineering applications for generating accurate pore morphologies of bone replacement materials and to consistently select similar bone specimens in bone bioreactor studies.</description><subject>Anisotropic permeability</subject><subject>Darcy's law</subject><subject>Fluid dynamics</subject><subject>MicroCT</subject><subject>Trabecular bone</subject><issn>2352-1872</issn><issn>2352-1872</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2017</creationdate><recordtype>article</recordtype><sourceid>DOA</sourceid><recordid>eNpVkk1r3DAQhk1paUKaP9BD0bEXu_rwh3QplCVtA4Fe0rMYSaOtFtvaSnZhoT8-cjcNyUmDNO_zDqO3qt4z2jDK-k-HxsQ5NbzUDeMNpfxVdclFx2smB_76WX1RXed8oJSyTrWDUm-rCy7bnoueXVZ_b_ISJlhCnEn0BOaQ45LiMVhyxDQhmDCG5UTCTJYEBu06QiLFGomBjI4U3RRsirt7Ujj7MO8LxJFjTFhnCyMSP67BEXeaoTRmksNUGJthfle98TBmvH48r6qfX2_ud9_rux_fbndf7morpOC1HwaKhisGvBsQUUBvBKCjzEnmlZdGMOX7waDzvTEDgKC2tdJy4bxSQlxVt2eui3DQx1QGTScdIeh_FzHtNaQl2BG1cUoCKzpnhranUlKBtG1d3w6895QV1ucz67iaCZ3FuexlfAF9-TKHX3of_-iupZKJDfDxEZDi7xXzoqeQLY4jzBjXrJlUbcekFKq08nNr2W_OCf2TDaN6S4E-6C0FekuBZlyXFBTRh-cDPkn-_7l4AN92spc</recordid><startdate>20170601</startdate><enddate>20170601</enddate><creator>Daish, C</creator><creator>Blanchard, R</creator><creator>Gulati, K</creator><creator>Losic, D</creator><creator>Findlay, D</creator><creator>Harvie, D J E</creator><creator>Pivonka, P</creator><general>Elsevier</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>5PM</scope><scope>DOA</scope></search><sort><creationdate>20170601</creationdate><title>Estimation of anisotropic permeability in trabecular bone based on microCT imaging and pore-scale fluid dynamics simulations</title><author>Daish, C ; Blanchard, R ; Gulati, K ; Losic, D ; Findlay, D ; Harvie, D J E ; Pivonka, P</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c3832-f770eb291a257eee3a6b3aed01d81f9f8b319f67bedf6bb7aa30c4c8c23df9933</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2017</creationdate><topic>Anisotropic permeability</topic><topic>Darcy's law</topic><topic>Fluid dynamics</topic><topic>MicroCT</topic><topic>Trabecular bone</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Daish, C</creatorcontrib><creatorcontrib>Blanchard, R</creatorcontrib><creatorcontrib>Gulati, K</creatorcontrib><creatorcontrib>Losic, D</creatorcontrib><creatorcontrib>Findlay, D</creatorcontrib><creatorcontrib>Harvie, D J E</creatorcontrib><creatorcontrib>Pivonka, P</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><collection>Directory of Open Access Journals</collection><jtitle>Bone Reports</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Daish, C</au><au>Blanchard, R</au><au>Gulati, K</au><au>Losic, D</au><au>Findlay, D</au><au>Harvie, D J E</au><au>Pivonka, P</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Estimation of anisotropic permeability in trabecular bone based on microCT imaging and pore-scale fluid dynamics simulations</atitle><jtitle>Bone Reports</jtitle><addtitle>Bone Rep</addtitle><date>2017-06-01</date><risdate>2017</risdate><volume>6</volume><issue>C</issue><spage>129</spage><epage>139</epage><pages>129-139</pages><issn>2352-1872</issn><eissn>2352-1872</eissn><abstract>In this paper, a comprehensive framework is proposed to estimate the anisotropic permeability matrix in trabecular bone specimens based on micro-computed tomography (microCT) imaging combined with pore-scale fluid dynamics simulations. Two essential steps in the proposed methodology are the selection of (i) a representative volume element (RVE) for calculation of trabecular bone permeability and (ii) a converged mesh for accurate calculation of pore fluid flow properties. Accurate estimates of trabecular bone porosities are obtained using a microCT image resolution of approximately 10 μm. We show that a trabecular bone RVE in the order of 2 × 2 × 2 mm is most suitable. Mesh convergence studies show that accurate fluid flow properties are obtained for a mesh size above 125,000 elements. Volume averaging of the pore-scale fluid flow properties allows calculation of the apparent permeability matrix of trabecular bone specimens. For the four specimens chosen, our numerical results show that the so obtained permeability coefficients are in excellent agreement with previously reported experimental data for both human and bovine trabecular bone samples. We also identified that bone samples taken from long bones generally exhibit a larger permeability in the longitudinal direction. The fact that all coefficients of the permeability matrix were different from zero indicates that bone samples are generally not harvested in the principal flow directions. The full permeability matrix was diagonalized by calculating the eigenvalues, while the eigenvectors showed how strongly the bone sample's orientations deviated from the principal flow directions. Porosity values of the four bone specimens range from 0.83 to 0.86, with a low standard deviation of ± 0.016, principal permeability values range from 0.22 to 1.45 ⋅ 10  m , with a high standard deviation of ± 0.33. Also, the anisotropic ratio ranged from 0.27 to 0.83, with high standard deviation. These results indicate that while the four specimens are quite similar in terms of average porosity, large variability exists with respect to permeability and specimen anisotropy. The utilized computational approach compares well with semi-analytical models based on homogenization theory. This methodology can be applied in bone tissue engineering applications for generating accurate pore morphologies of bone replacement materials and to consistently select similar bone specimens in bone bioreactor studies.</abstract><cop>United States</cop><pub>Elsevier</pub><pmid>28462361</pmid><doi>10.1016/j.bonr.2016.12.002</doi><tpages>11</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 2352-1872
ispartof Bone Reports, 2017-06, Vol.6 (C), p.129-139
issn 2352-1872
2352-1872
language eng
recordid cdi_doaj_primary_oai_doaj_org_article_bd98a13dfdb74608803e044d64726f01
source ScienceDirect®; PubMed Central
subjects Anisotropic permeability
Darcy's law
Fluid dynamics
MicroCT
Trabecular bone
title Estimation of anisotropic permeability in trabecular bone based on microCT imaging and pore-scale fluid dynamics simulations
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-08T11%3A18%3A00IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_doaj_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Estimation%20of%20anisotropic%20permeability%20in%20trabecular%20bone%20based%20on%20microCT%20imaging%20and%20pore-scale%20fluid%20dynamics%20simulations&rft.jtitle=Bone%20Reports&rft.au=Daish,%20C&rft.date=2017-06-01&rft.volume=6&rft.issue=C&rft.spage=129&rft.epage=139&rft.pages=129-139&rft.issn=2352-1872&rft.eissn=2352-1872&rft_id=info:doi/10.1016/j.bonr.2016.12.002&rft_dat=%3Cproquest_doaj_%3E1894518839%3C/proquest_doaj_%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c3832-f770eb291a257eee3a6b3aed01d81f9f8b319f67bedf6bb7aa30c4c8c23df9933%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=1894518839&rft_id=info:pmid/28462361&rfr_iscdi=true