Loading…
Tackling CD147 exosome-based cell-cell signaling by electrochemical biosensing for early colorectal cancer detection
The great opportunities represented by exosomes in liquid biopsy diagnostics and the relevance of CD147 protein as diagnostic and prognostic cancer biomarker led us to develop the first bio-electroanalytical platform for the determination of exosomal CD147 (exoCD147) by exploiting micro-sized magnet...
Saved in:
Published in: | Biosensors and bioelectronics. X 2022-09, Vol.11, p.100192, Article 100192 |
---|---|
Main Authors: | , , , , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | The great opportunities represented by exosomes in liquid biopsy diagnostics and the relevance of CD147 protein as diagnostic and prognostic cancer biomarker led us to develop the first bio-electroanalytical platform for the determination of exosomal CD147 (exoCD147) by exploiting micro-sized magnetic beads coated with specific anti-CD147 antibodies. The captured exosomal target protein was sandwiched by specific biotin functionalized detector antibodies followed by attaching streptavidin-HRP conjugate to perform the amperometric reading using screen-printed carbon electrodes (SPCEs) as electrode transducers in the presence of hydroquinone (HQ) and H2O2. The analytical and operational characteristics achieved by implementing this simple methodology allowed the sensitive (LOD 29 pg mL−1) and selective determination of CD147 and the analysis of exoCD147 in different but inter-related real clinical scenarios including lysed and entire exosomes previously isolated from CRC cell lines with different metastatic potential. The obtained results, in agreement with those provided by ELISA and WB, proved the reliability of the developed immunosensor and its potential to isolate or identify specific subpopulations of exosomes based on the differential expression of characteristic surface biomarkers.
[Display omitted]
•First bio-electroanalytical platform for the determination of exosomal CD147.•Magnetic microbeads-assisted sandwich immunoplatform.•Amperometric transduction at screen-printed electrodes.•LOD of 29 pg mL−1 for CD147 standards.•Accurate analysis in lysed and entire exosomes isolated from colorectal cancer cells. |
---|---|
ISSN: | 2590-1370 2590-1370 |
DOI: | 10.1016/j.biosx.2022.100192 |