A Fast and Accurate Calculation Method of Line Breaking Power Flow Based on Taylor Expansion

In order to quickly obtain the voltage value of each node after the power system line is disconnected, a fast and accurate calculation method of breaking voltage based on Taylor series expansion is proposed in this study, which can calculate the value of nodal voltage of the system in a short time....

Full description

Saved in:
Bibliographic Details
Published in:Frontiers in energy research 2022-07, Vol.10
Main Authors: Li, Shuaihu, Zhao, Xiang, Liang, Wenju, Hossain, Md Tanjid, Zhang, Zhidan
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c354t-a1e7ddf115ceaf6083775d9c5c0fb0edc96fcc5ad4de4dfdabd20d0917b3b36d3
cites cdi_FETCH-LOGICAL-c354t-a1e7ddf115ceaf6083775d9c5c0fb0edc96fcc5ad4de4dfdabd20d0917b3b36d3
container_end_page
container_issue
container_start_page
container_title Frontiers in energy research
container_volume 10
creator Li, Shuaihu
Zhao, Xiang
Liang, Wenju
Hossain, Md Tanjid
Zhang, Zhidan
description In order to quickly obtain the voltage value of each node after the power system line is disconnected, a fast and accurate calculation method of breaking voltage based on Taylor series expansion is proposed in this study, which can calculate the value of nodal voltage of the system in a short time. At first, a breaking parameter is introduced into the admittance of the disconnected line, and a nonlinear disconnection function is constructed about the breaking parameter. After the line is disconnected, the voltage of each node and the admittance matrix of each node are functions of the relevant parameters, and then, the Taylor series is used to expand. The voltage of each node of the system before breaking is considered as the initial value of the Taylor series, and the first, second, and third derivatives of the node voltage with respect to the parameter are considered as the correction term; the voltage of each node of the system is calculated after the line is disconnected. Finally, the simulation results of the IEEE 14-node system are used to verify the correctness of the proposed method.
doi_str_mv 10.3389/fenrg.2022.943946
format article
fullrecord <record><control><sourceid>doaj_cross</sourceid><recordid>TN_cdi_doaj_primary_oai_doaj_org_article_be5dfe08dce942bfb769807db3f0511e</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><doaj_id>oai_doaj_org_article_be5dfe08dce942bfb769807db3f0511e</doaj_id><sourcerecordid>oai_doaj_org_article_be5dfe08dce942bfb769807db3f0511e</sourcerecordid><originalsourceid>FETCH-LOGICAL-c354t-a1e7ddf115ceaf6083775d9c5c0fb0edc96fcc5ad4de4dfdabd20d0917b3b36d3</originalsourceid><addsrcrecordid>eNpNkM1KAzEUhYMoWLQP4C4v0JpMJjOTZVtaLVR0UcGFEO7k3tSp46RkptS-vf0RcXUPl3O-xcfYnRRDpQpz76mJq2EikmRoUmXS7IL1ksRkA22Kt8t_-Zr123YthJAq0akUPfY-4jNoOw4N8pFz2wgd8QnUbltDV4WGP1H3EZAHzxdVQ3wcCT6rZsVfwo4in9Vhx8fQ0qHR8CXs6xD59HsDTXsY37IrD3VL_d97w15n0-XkcbB4fphPRouBUzrtBiApR_RSakfgM1GoPNdonHbCl4LQmcw7pwFTpBQ9QomJQGFkXqpSZahu2PzMxQBru4nVF8S9DVDZ0yPElYXYVa4mW5JGT6JARyZNSl_mmSlEjqXyQktJB5Y8s1wMbRvJ__GksEfb9mTbHm3bs231A5V4dZU</addsrcrecordid><sourcetype>Open Website</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>A Fast and Accurate Calculation Method of Line Breaking Power Flow Based on Taylor Expansion</title><source>ROAD: Directory of Open Access Scholarly Resources</source><creator>Li, Shuaihu ; Zhao, Xiang ; Liang, Wenju ; Hossain, Md Tanjid ; Zhang, Zhidan</creator><creatorcontrib>Li, Shuaihu ; Zhao, Xiang ; Liang, Wenju ; Hossain, Md Tanjid ; Zhang, Zhidan</creatorcontrib><description>In order to quickly obtain the voltage value of each node after the power system line is disconnected, a fast and accurate calculation method of breaking voltage based on Taylor series expansion is proposed in this study, which can calculate the value of nodal voltage of the system in a short time. At first, a breaking parameter is introduced into the admittance of the disconnected line, and a nonlinear disconnection function is constructed about the breaking parameter. After the line is disconnected, the voltage of each node and the admittance matrix of each node are functions of the relevant parameters, and then, the Taylor series is used to expand. The voltage of each node of the system before breaking is considered as the initial value of the Taylor series, and the first, second, and third derivatives of the node voltage with respect to the parameter are considered as the correction term; the voltage of each node of the system is calculated after the line is disconnected. Finally, the simulation results of the IEEE 14-node system are used to verify the correctness of the proposed method.</description><identifier>ISSN: 2296-598X</identifier><identifier>EISSN: 2296-598X</identifier><identifier>DOI: 10.3389/fenrg.2022.943946</identifier><language>eng</language><publisher>Frontiers Media S.A</publisher><subject>breaking power flow ; fast and accurate calculation ; nonlinear breaking function ; power system ; static safety analysis</subject><ispartof>Frontiers in energy research, 2022-07, Vol.10</ispartof><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c354t-a1e7ddf115ceaf6083775d9c5c0fb0edc96fcc5ad4de4dfdabd20d0917b3b36d3</citedby><cites>FETCH-LOGICAL-c354t-a1e7ddf115ceaf6083775d9c5c0fb0edc96fcc5ad4de4dfdabd20d0917b3b36d3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27901,27902</link.rule.ids></links><search><creatorcontrib>Li, Shuaihu</creatorcontrib><creatorcontrib>Zhao, Xiang</creatorcontrib><creatorcontrib>Liang, Wenju</creatorcontrib><creatorcontrib>Hossain, Md Tanjid</creatorcontrib><creatorcontrib>Zhang, Zhidan</creatorcontrib><title>A Fast and Accurate Calculation Method of Line Breaking Power Flow Based on Taylor Expansion</title><title>Frontiers in energy research</title><description>In order to quickly obtain the voltage value of each node after the power system line is disconnected, a fast and accurate calculation method of breaking voltage based on Taylor series expansion is proposed in this study, which can calculate the value of nodal voltage of the system in a short time. At first, a breaking parameter is introduced into the admittance of the disconnected line, and a nonlinear disconnection function is constructed about the breaking parameter. After the line is disconnected, the voltage of each node and the admittance matrix of each node are functions of the relevant parameters, and then, the Taylor series is used to expand. The voltage of each node of the system before breaking is considered as the initial value of the Taylor series, and the first, second, and third derivatives of the node voltage with respect to the parameter are considered as the correction term; the voltage of each node of the system is calculated after the line is disconnected. Finally, the simulation results of the IEEE 14-node system are used to verify the correctness of the proposed method.</description><subject>breaking power flow</subject><subject>fast and accurate calculation</subject><subject>nonlinear breaking function</subject><subject>power system</subject><subject>static safety analysis</subject><issn>2296-598X</issn><issn>2296-598X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2022</creationdate><recordtype>article</recordtype><sourceid>DOA</sourceid><recordid>eNpNkM1KAzEUhYMoWLQP4C4v0JpMJjOTZVtaLVR0UcGFEO7k3tSp46RkptS-vf0RcXUPl3O-xcfYnRRDpQpz76mJq2EikmRoUmXS7IL1ksRkA22Kt8t_-Zr123YthJAq0akUPfY-4jNoOw4N8pFz2wgd8QnUbltDV4WGP1H3EZAHzxdVQ3wcCT6rZsVfwo4in9Vhx8fQ0qHR8CXs6xD59HsDTXsY37IrD3VL_d97w15n0-XkcbB4fphPRouBUzrtBiApR_RSakfgM1GoPNdonHbCl4LQmcw7pwFTpBQ9QomJQGFkXqpSZahu2PzMxQBru4nVF8S9DVDZ0yPElYXYVa4mW5JGT6JARyZNSl_mmSlEjqXyQktJB5Y8s1wMbRvJ__GksEfb9mTbHm3bs231A5V4dZU</recordid><startdate>20220714</startdate><enddate>20220714</enddate><creator>Li, Shuaihu</creator><creator>Zhao, Xiang</creator><creator>Liang, Wenju</creator><creator>Hossain, Md Tanjid</creator><creator>Zhang, Zhidan</creator><general>Frontiers Media S.A</general><scope>AAYXX</scope><scope>CITATION</scope><scope>DOA</scope></search><sort><creationdate>20220714</creationdate><title>A Fast and Accurate Calculation Method of Line Breaking Power Flow Based on Taylor Expansion</title><author>Li, Shuaihu ; Zhao, Xiang ; Liang, Wenju ; Hossain, Md Tanjid ; Zhang, Zhidan</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c354t-a1e7ddf115ceaf6083775d9c5c0fb0edc96fcc5ad4de4dfdabd20d0917b3b36d3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2022</creationdate><topic>breaking power flow</topic><topic>fast and accurate calculation</topic><topic>nonlinear breaking function</topic><topic>power system</topic><topic>static safety analysis</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Li, Shuaihu</creatorcontrib><creatorcontrib>Zhao, Xiang</creatorcontrib><creatorcontrib>Liang, Wenju</creatorcontrib><creatorcontrib>Hossain, Md Tanjid</creatorcontrib><creatorcontrib>Zhang, Zhidan</creatorcontrib><collection>CrossRef</collection><collection>Directory of Open Access Journals</collection><jtitle>Frontiers in energy research</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Li, Shuaihu</au><au>Zhao, Xiang</au><au>Liang, Wenju</au><au>Hossain, Md Tanjid</au><au>Zhang, Zhidan</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A Fast and Accurate Calculation Method of Line Breaking Power Flow Based on Taylor Expansion</atitle><jtitle>Frontiers in energy research</jtitle><date>2022-07-14</date><risdate>2022</risdate><volume>10</volume><issn>2296-598X</issn><eissn>2296-598X</eissn><abstract>In order to quickly obtain the voltage value of each node after the power system line is disconnected, a fast and accurate calculation method of breaking voltage based on Taylor series expansion is proposed in this study, which can calculate the value of nodal voltage of the system in a short time. At first, a breaking parameter is introduced into the admittance of the disconnected line, and a nonlinear disconnection function is constructed about the breaking parameter. After the line is disconnected, the voltage of each node and the admittance matrix of each node are functions of the relevant parameters, and then, the Taylor series is used to expand. The voltage of each node of the system before breaking is considered as the initial value of the Taylor series, and the first, second, and third derivatives of the node voltage with respect to the parameter are considered as the correction term; the voltage of each node of the system is calculated after the line is disconnected. Finally, the simulation results of the IEEE 14-node system are used to verify the correctness of the proposed method.</abstract><pub>Frontiers Media S.A</pub><doi>10.3389/fenrg.2022.943946</doi><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 2296-598X
ispartof Frontiers in energy research, 2022-07, Vol.10
issn 2296-598X
2296-598X
language eng
recordid cdi_doaj_primary_oai_doaj_org_article_be5dfe08dce942bfb769807db3f0511e
source ROAD: Directory of Open Access Scholarly Resources
subjects breaking power flow
fast and accurate calculation
nonlinear breaking function
power system
static safety analysis
title A Fast and Accurate Calculation Method of Line Breaking Power Flow Based on Taylor Expansion
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-09T08%3A05%3A57IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-doaj_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20Fast%20and%20Accurate%20Calculation%20Method%20of%20Line%20Breaking%20Power%20Flow%20Based%20on%20Taylor%20Expansion&rft.jtitle=Frontiers%20in%20energy%20research&rft.au=Li,%20Shuaihu&rft.date=2022-07-14&rft.volume=10&rft.issn=2296-598X&rft.eissn=2296-598X&rft_id=info:doi/10.3389/fenrg.2022.943946&rft_dat=%3Cdoaj_cross%3Eoai_doaj_org_article_be5dfe08dce942bfb769807db3f0511e%3C/doaj_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c354t-a1e7ddf115ceaf6083775d9c5c0fb0edc96fcc5ad4de4dfdabd20d0917b3b36d3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true