A New Approach to the Assessment of the Reduction in Visibility Caused by Fires of Electrical Cables
Electricity is the most important form of household energy and one of the most important forms of energy for industry and transport. Electrical distribution in construction and transport is almost exclusively implemented using electrical cables. One of the unresolved problems associated with electri...
Saved in:
Published in: | Safety (Basel) 2019, Vol.5 (3), p.44 |
---|---|
Main Authors: | , , , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | |
---|---|
cites | cdi_FETCH-LOGICAL-c326t-e0c01f0ea0bae9a20554503ea720bff33266e02dc83ad907ee1daa03d837243b3 |
container_end_page | |
container_issue | 3 |
container_start_page | 44 |
container_title | Safety (Basel) |
container_volume | 5 |
creator | Martinka, Jozef Rantuch, Peter Rolinec, Marek Pokorny, Jiri Balog, Karol Kucera, Petr Rybakowski, Marek Sulova, Janka |
description | Electricity is the most important form of household energy and one of the most important forms of energy for industry and transport. Electrical distribution in construction and transport is almost exclusively implemented using electrical cables. One of the unresolved problems associated with electrical cables is the release of smoke and the resulting reduction of visibility in case of fire in the area. In this study, a new approach was developed to assess the reduction of visibility in an area affected by an electrical cable fire. This approach is based on the determination of the critical ratio of smoke volume (in the smoke layer and exhausted from the fire compartment) to the length of the burning cable, through which the visibility of reflective and illuminated signs was reduced to a lower limit value (a standard of 10 m). The input data for this approach was the extinction area of the smoke released from one meter of burning cable and the length of the cables in the area. This approach was used to test two power cables (CHKE-V J3x1.5 and CHKE-R J3x1.5) and one signal cable J-H(St)H 1 × 2 × 0.8 with the B2ca, s1, d1, a1 fire reaction class. The smoke extinction area of the examined cables was determined using a cone calorimeter at a heat flux of 50 kW/m2. The obtained data showed that in order to maintain a visibility of 10 m for reflective signs, the critical ratio of smoke volume to length of burning cable was 7.5 m3/m. For illuminated signs, the critical ratio was 2.8 m3/m. The relationship between burning length and visibility allows the calculation of visibility in the fire compartment affected by cable fire only from cables length. |
doi_str_mv | 10.3390/safety5030044 |
format | article |
fullrecord | <record><control><sourceid>proquest_doaj_</sourceid><recordid>TN_cdi_doaj_primary_oai_doaj_org_article_c2fad75d46474acd8e896c4ed3c71323</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><doaj_id>oai_doaj_org_article_c2fad75d46474acd8e896c4ed3c71323</doaj_id><sourcerecordid>2550246573</sourcerecordid><originalsourceid>FETCH-LOGICAL-c326t-e0c01f0ea0bae9a20554503ea720bff33266e02dc83ad907ee1daa03d837243b3</originalsourceid><addsrcrecordid>eNpVkU1LAzEQhhdRULRH7wHPq7OZ7G73WEqrgiiIircwm8zalLWpSYr037u1Inqa4Z2Hd76y7LyAS8QGriJ1nLYlIIBSB9mJxALzsq5eD__kx9koxiUAFA0iNM1JZifinj_FZL0OnsxCJC_SgsUkRo7xnVdJ-O5beWS7Mcn5lXAr8eKia13v0lZMaRPZinYr5i5w3OGznk0KzlA_VNue41l21FEfefQTT7Pn-expepPfPVzfTid3uUFZpZzBQNEBE7TEDUkoSzUsxFRLaLsOB6hikNaMkWwDNXNhiQDtGGupsMXT7Hbvaz0t9Tq4dwpb7cnpb8GHN00hOdOzNrIjW5dWVapWZOyYx01lFFs0dYESB6-LvddwmI8Nx6SXfhNWw_haliVIVZX1jsr3lAk-xsDdb9cC9O4v-t9f8AtOJYDI</addsrcrecordid><sourcetype>Open Website</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2550246573</pqid></control><display><type>article</type><title>A New Approach to the Assessment of the Reduction in Visibility Caused by Fires of Electrical Cables</title><source>Publicly Available Content Database</source><source>ABI/INFORM Global</source><creator>Martinka, Jozef ; Rantuch, Peter ; Rolinec, Marek ; Pokorny, Jiri ; Balog, Karol ; Kucera, Petr ; Rybakowski, Marek ; Sulova, Janka</creator><creatorcontrib>Martinka, Jozef ; Rantuch, Peter ; Rolinec, Marek ; Pokorny, Jiri ; Balog, Karol ; Kucera, Petr ; Rybakowski, Marek ; Sulova, Janka</creatorcontrib><description>Electricity is the most important form of household energy and one of the most important forms of energy for industry and transport. Electrical distribution in construction and transport is almost exclusively implemented using electrical cables. One of the unresolved problems associated with electrical cables is the release of smoke and the resulting reduction of visibility in case of fire in the area. In this study, a new approach was developed to assess the reduction of visibility in an area affected by an electrical cable fire. This approach is based on the determination of the critical ratio of smoke volume (in the smoke layer and exhausted from the fire compartment) to the length of the burning cable, through which the visibility of reflective and illuminated signs was reduced to a lower limit value (a standard of 10 m). The input data for this approach was the extinction area of the smoke released from one meter of burning cable and the length of the cables in the area. This approach was used to test two power cables (CHKE-V J3x1.5 and CHKE-R J3x1.5) and one signal cable J-H(St)H 1 × 2 × 0.8 with the B2ca, s1, d1, a1 fire reaction class. The smoke extinction area of the examined cables was determined using a cone calorimeter at a heat flux of 50 kW/m2. The obtained data showed that in order to maintain a visibility of 10 m for reflective signs, the critical ratio of smoke volume to length of burning cable was 7.5 m3/m. For illuminated signs, the critical ratio was 2.8 m3/m. The relationship between burning length and visibility allows the calculation of visibility in the fire compartment affected by cable fire only from cables length.</description><identifier>ISSN: 2313-576X</identifier><identifier>EISSN: 2313-576X</identifier><identifier>DOI: 10.3390/safety5030044</identifier><language>eng</language><publisher>Basel: MDPI AG</publisher><subject>Cables ; Electric currents ; electrical cable ; electrical energy ; Electricity ; energy security ; fire risk ; Fires ; Heat ; Insulation ; Light ; Polymers ; safety ; smoke ; Toxicity ; visibility reduction</subject><ispartof>Safety (Basel), 2019, Vol.5 (3), p.44</ispartof><rights>2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c326t-e0c01f0ea0bae9a20554503ea720bff33266e02dc83ad907ee1daa03d837243b3</cites><orcidid>0000-0001-5826-8323 ; 0000-0002-0060-5785</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.proquest.com/docview/2550246573/fulltextPDF?pq-origsite=primo$$EPDF$$P50$$Gproquest$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.proquest.com/docview/2550246573?pq-origsite=primo$$EHTML$$P50$$Gproquest$$Hfree_for_read</linktohtml><link.rule.ids>314,780,784,4024,11688,25753,27923,27924,27925,36060,37012,44363,44590,74895,75126</link.rule.ids></links><search><creatorcontrib>Martinka, Jozef</creatorcontrib><creatorcontrib>Rantuch, Peter</creatorcontrib><creatorcontrib>Rolinec, Marek</creatorcontrib><creatorcontrib>Pokorny, Jiri</creatorcontrib><creatorcontrib>Balog, Karol</creatorcontrib><creatorcontrib>Kucera, Petr</creatorcontrib><creatorcontrib>Rybakowski, Marek</creatorcontrib><creatorcontrib>Sulova, Janka</creatorcontrib><title>A New Approach to the Assessment of the Reduction in Visibility Caused by Fires of Electrical Cables</title><title>Safety (Basel)</title><description>Electricity is the most important form of household energy and one of the most important forms of energy for industry and transport. Electrical distribution in construction and transport is almost exclusively implemented using electrical cables. One of the unresolved problems associated with electrical cables is the release of smoke and the resulting reduction of visibility in case of fire in the area. In this study, a new approach was developed to assess the reduction of visibility in an area affected by an electrical cable fire. This approach is based on the determination of the critical ratio of smoke volume (in the smoke layer and exhausted from the fire compartment) to the length of the burning cable, through which the visibility of reflective and illuminated signs was reduced to a lower limit value (a standard of 10 m). The input data for this approach was the extinction area of the smoke released from one meter of burning cable and the length of the cables in the area. This approach was used to test two power cables (CHKE-V J3x1.5 and CHKE-R J3x1.5) and one signal cable J-H(St)H 1 × 2 × 0.8 with the B2ca, s1, d1, a1 fire reaction class. The smoke extinction area of the examined cables was determined using a cone calorimeter at a heat flux of 50 kW/m2. The obtained data showed that in order to maintain a visibility of 10 m for reflective signs, the critical ratio of smoke volume to length of burning cable was 7.5 m3/m. For illuminated signs, the critical ratio was 2.8 m3/m. The relationship between burning length and visibility allows the calculation of visibility in the fire compartment affected by cable fire only from cables length.</description><subject>Cables</subject><subject>Electric currents</subject><subject>electrical cable</subject><subject>electrical energy</subject><subject>Electricity</subject><subject>energy security</subject><subject>fire risk</subject><subject>Fires</subject><subject>Heat</subject><subject>Insulation</subject><subject>Light</subject><subject>Polymers</subject><subject>safety</subject><subject>smoke</subject><subject>Toxicity</subject><subject>visibility reduction</subject><issn>2313-576X</issn><issn>2313-576X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2019</creationdate><recordtype>article</recordtype><sourceid>M0C</sourceid><sourceid>PIMPY</sourceid><sourceid>DOA</sourceid><recordid>eNpVkU1LAzEQhhdRULRH7wHPq7OZ7G73WEqrgiiIircwm8zalLWpSYr037u1Inqa4Z2Hd76y7LyAS8QGriJ1nLYlIIBSB9mJxALzsq5eD__kx9koxiUAFA0iNM1JZifinj_FZL0OnsxCJC_SgsUkRo7xnVdJ-O5beWS7Mcn5lXAr8eKia13v0lZMaRPZinYr5i5w3OGznk0KzlA_VNue41l21FEfefQTT7Pn-expepPfPVzfTid3uUFZpZzBQNEBE7TEDUkoSzUsxFRLaLsOB6hikNaMkWwDNXNhiQDtGGupsMXT7Hbvaz0t9Tq4dwpb7cnpb8GHN00hOdOzNrIjW5dWVapWZOyYx01lFFs0dYESB6-LvddwmI8Nx6SXfhNWw_haliVIVZX1jsr3lAk-xsDdb9cC9O4v-t9f8AtOJYDI</recordid><startdate>2019</startdate><enddate>2019</enddate><creator>Martinka, Jozef</creator><creator>Rantuch, Peter</creator><creator>Rolinec, Marek</creator><creator>Pokorny, Jiri</creator><creator>Balog, Karol</creator><creator>Kucera, Petr</creator><creator>Rybakowski, Marek</creator><creator>Sulova, Janka</creator><general>MDPI AG</general><scope>AAYXX</scope><scope>CITATION</scope><scope>3V.</scope><scope>7WY</scope><scope>7WZ</scope><scope>7XB</scope><scope>87Z</scope><scope>8FK</scope><scope>8FL</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>BEZIV</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>FRNLG</scope><scope>F~G</scope><scope>K60</scope><scope>K6~</scope><scope>L.-</scope><scope>M0C</scope><scope>PIMPY</scope><scope>PQBIZ</scope><scope>PQBZA</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>Q9U</scope><scope>DOA</scope><orcidid>https://orcid.org/0000-0001-5826-8323</orcidid><orcidid>https://orcid.org/0000-0002-0060-5785</orcidid></search><sort><creationdate>2019</creationdate><title>A New Approach to the Assessment of the Reduction in Visibility Caused by Fires of Electrical Cables</title><author>Martinka, Jozef ; Rantuch, Peter ; Rolinec, Marek ; Pokorny, Jiri ; Balog, Karol ; Kucera, Petr ; Rybakowski, Marek ; Sulova, Janka</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c326t-e0c01f0ea0bae9a20554503ea720bff33266e02dc83ad907ee1daa03d837243b3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2019</creationdate><topic>Cables</topic><topic>Electric currents</topic><topic>electrical cable</topic><topic>electrical energy</topic><topic>Electricity</topic><topic>energy security</topic><topic>fire risk</topic><topic>Fires</topic><topic>Heat</topic><topic>Insulation</topic><topic>Light</topic><topic>Polymers</topic><topic>safety</topic><topic>smoke</topic><topic>Toxicity</topic><topic>visibility reduction</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Martinka, Jozef</creatorcontrib><creatorcontrib>Rantuch, Peter</creatorcontrib><creatorcontrib>Rolinec, Marek</creatorcontrib><creatorcontrib>Pokorny, Jiri</creatorcontrib><creatorcontrib>Balog, Karol</creatorcontrib><creatorcontrib>Kucera, Petr</creatorcontrib><creatorcontrib>Rybakowski, Marek</creatorcontrib><creatorcontrib>Sulova, Janka</creatorcontrib><collection>CrossRef</collection><collection>ProQuest Central (Corporate)</collection><collection>ProQuest_ABI/INFORM Collection</collection><collection>ABI/INFORM Global (PDF only)</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>ABI/INFORM Collection</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>ABI/INFORM Collection (Alumni Edition)</collection><collection>ProQuest Central (Alumni)</collection><collection>ProQuest Central</collection><collection>ProQuest Central Essentials</collection><collection>ProQuest Central</collection><collection>Business Premium Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central Korea</collection><collection>Business Premium Collection (Alumni)</collection><collection>ABI/INFORM Global (Corporate)</collection><collection>ProQuest Business Collection (Alumni Edition)</collection><collection>ProQuest Business Collection</collection><collection>ABI/INFORM Professional Advanced</collection><collection>ABI/INFORM Global</collection><collection>Publicly Available Content Database</collection><collection>One Business</collection><collection>ProQuest One Business (Alumni)</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>ProQuest Central Basic</collection><collection>DOAJ Directory of Open Access Journals</collection><jtitle>Safety (Basel)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Martinka, Jozef</au><au>Rantuch, Peter</au><au>Rolinec, Marek</au><au>Pokorny, Jiri</au><au>Balog, Karol</au><au>Kucera, Petr</au><au>Rybakowski, Marek</au><au>Sulova, Janka</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A New Approach to the Assessment of the Reduction in Visibility Caused by Fires of Electrical Cables</atitle><jtitle>Safety (Basel)</jtitle><date>2019</date><risdate>2019</risdate><volume>5</volume><issue>3</issue><spage>44</spage><pages>44-</pages><issn>2313-576X</issn><eissn>2313-576X</eissn><abstract>Electricity is the most important form of household energy and one of the most important forms of energy for industry and transport. Electrical distribution in construction and transport is almost exclusively implemented using electrical cables. One of the unresolved problems associated with electrical cables is the release of smoke and the resulting reduction of visibility in case of fire in the area. In this study, a new approach was developed to assess the reduction of visibility in an area affected by an electrical cable fire. This approach is based on the determination of the critical ratio of smoke volume (in the smoke layer and exhausted from the fire compartment) to the length of the burning cable, through which the visibility of reflective and illuminated signs was reduced to a lower limit value (a standard of 10 m). The input data for this approach was the extinction area of the smoke released from one meter of burning cable and the length of the cables in the area. This approach was used to test two power cables (CHKE-V J3x1.5 and CHKE-R J3x1.5) and one signal cable J-H(St)H 1 × 2 × 0.8 with the B2ca, s1, d1, a1 fire reaction class. The smoke extinction area of the examined cables was determined using a cone calorimeter at a heat flux of 50 kW/m2. The obtained data showed that in order to maintain a visibility of 10 m for reflective signs, the critical ratio of smoke volume to length of burning cable was 7.5 m3/m. For illuminated signs, the critical ratio was 2.8 m3/m. The relationship between burning length and visibility allows the calculation of visibility in the fire compartment affected by cable fire only from cables length.</abstract><cop>Basel</cop><pub>MDPI AG</pub><doi>10.3390/safety5030044</doi><orcidid>https://orcid.org/0000-0001-5826-8323</orcidid><orcidid>https://orcid.org/0000-0002-0060-5785</orcidid><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 2313-576X |
ispartof | Safety (Basel), 2019, Vol.5 (3), p.44 |
issn | 2313-576X 2313-576X |
language | eng |
recordid | cdi_doaj_primary_oai_doaj_org_article_c2fad75d46474acd8e896c4ed3c71323 |
source | Publicly Available Content Database; ABI/INFORM Global |
subjects | Cables Electric currents electrical cable electrical energy Electricity energy security fire risk Fires Heat Insulation Light Polymers safety smoke Toxicity visibility reduction |
title | A New Approach to the Assessment of the Reduction in Visibility Caused by Fires of Electrical Cables |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-03T07%3A17%3A01IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_doaj_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20New%20Approach%20to%20the%20Assessment%20of%20the%20Reduction%20in%20Visibility%20Caused%20by%20Fires%20of%20Electrical%20Cables&rft.jtitle=Safety%20(Basel)&rft.au=Martinka,%20Jozef&rft.date=2019&rft.volume=5&rft.issue=3&rft.spage=44&rft.pages=44-&rft.issn=2313-576X&rft.eissn=2313-576X&rft_id=info:doi/10.3390/safety5030044&rft_dat=%3Cproquest_doaj_%3E2550246573%3C/proquest_doaj_%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c326t-e0c01f0ea0bae9a20554503ea720bff33266e02dc83ad907ee1daa03d837243b3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2550246573&rft_id=info:pmid/&rfr_iscdi=true |