Loading…
Efficacy of Esthetic Retainers: Clinical Comparison between Multistranded Wires and Direct-Bond Glass Fiber-Reinforced Composite Splints
The purpose of this longitudinal prospective randomized study was to evaluate the reliability of two different types of orthodontic retainers in clinical use: a multistrand stainless steel wire and a polyethylene ribbon-reinforced resin composite. Moreover the level of satisfaction of the patient ab...
Saved in:
Published in: | International Journal of Dentistry 2011-01, Vol.2011 (2011), p.180-184 |
---|---|
Main Authors: | , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-a572t-23b94bf4597d8a2c0f5ddf74e9e4ef2d13bf7b4cbc8ae4b6a03c7b77de9cbb483 |
---|---|
cites | cdi_FETCH-LOGICAL-a572t-23b94bf4597d8a2c0f5ddf74e9e4ef2d13bf7b4cbc8ae4b6a03c7b77de9cbb483 |
container_end_page | 184 |
container_issue | 2011 |
container_start_page | 180 |
container_title | International Journal of Dentistry |
container_volume | 2011 |
creator | Scribante, Andrea Sfondrini, Maria Francesca Broggini, Simona D'Allocco, Marina Gandini, Paola |
description | The purpose of this longitudinal prospective randomized study was to evaluate the reliability of two different types of orthodontic retainers in clinical use: a multistrand stainless steel wire and a polyethylene ribbon-reinforced resin composite. Moreover the level of satisfaction of the patient about the esthetic result was also analyzed by means of a Visual Analogue Scale (VAS). 34 patients (9 boys and 25 girls, mean age 14.3), in the finishing phase of orthodontic treatment, were selected for the study. Since splints were applied the number, cause, and date of splint failures were recorded for each single tooth over 12 months. Statistical analysis was performed using a paired t-test, Kaplan Meier survival estimates, and the log-rank test. Kruskal Wallis test was performed to analyze VAS recordings. Differences between the bond failure rates were not statistically significant. Esthetic result of VAS was significantly higher for polyethylene ribbon-reinforced resin retainers than for stainless steel wires. |
doi_str_mv | 10.1155/2011/548356 |
format | article |
fullrecord | <record><control><sourceid>proquest_doaj_</sourceid><recordid>TN_cdi_doaj_primary_oai_doaj_org_article_c3bef12676e240c1ba83a55340631a54</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><airiti_id>P20160526004_201112_201702240004_201702240004_180_184</airiti_id><doaj_id>oai_doaj_org_article_c3bef12676e240c1ba83a55340631a54</doaj_id><sourcerecordid>906154145</sourcerecordid><originalsourceid>FETCH-LOGICAL-a572t-23b94bf4597d8a2c0f5ddf74e9e4ef2d13bf7b4cbc8ae4b6a03c7b77de9cbb483</originalsourceid><addsrcrecordid>eNqFkk1v1DAQQCMEolXpiTPINyRQqL-T5VAJlm2ptAhUQBwt2xl3XWXjxfZS9R_ws3GaZaEncvHYfnrjzExVPSX4NSFCnFBMyIngLRPyQXVIZNvUbcPkw31M24PqOKVrXD5GuCDycXVAKSnhrDmsfi2c81bbWxQcWqS8guwtuoSs_QAxvUHz3g8F6NE8rDc6-hQGZCDfAAzo47bPPuWohw469N1HSKjE6H2JbK7fhRKf9zoldOYNxPoS_OBCtAUebSH5DOjLpmTI6Un1yOk-wfFuPaq-nS2-zj_Uy0_nF_O3y1qLhuaaMjPjxo2P71pNLXai61zDYQYcHO0IM64x3BrbauBGasxsY5qmg5k1ptTpqLqYvF3Q12oT_VrHWxW0V3cHIV4pHUsNelCWGXCEykYC5dgSo1umhWAcS0a04MV1Ork2W7OGzsJQatHfk96_GfxKXYWfilEspCRF8GIniOHHFlJWa58s9L0eIGyTmmFJBC-tKuSribQxpBTB7bMQrMZJUOMkqGkSCv3834ft2T99L8DLCVj5odM3_j-2ZxMMBQGn9zBvsRDjXyyne-2jz15dh20cSg_V52KRWFCJMb8zEjouDaalnruzvxvSltwtZ78BGmDb9Q</addsrcrecordid><sourcetype>Open Website</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>906154145</pqid></control><display><type>article</type><title>Efficacy of Esthetic Retainers: Clinical Comparison between Multistranded Wires and Direct-Bond Glass Fiber-Reinforced Composite Splints</title><source>PubMed (Medline)</source><source>Publicly Available Content Database (Proquest) (PQ_SDU_P3)</source><source>Wiley Online Library Open Access</source><creator>Scribante, Andrea ; Sfondrini, Maria Francesca ; Broggini, Simona ; D'Allocco, Marina ; Gandini, Paola</creator><contributor>Ariji, Eiichiro</contributor><creatorcontrib>Scribante, Andrea ; Sfondrini, Maria Francesca ; Broggini, Simona ; D'Allocco, Marina ; Gandini, Paola ; Ariji, Eiichiro</creatorcontrib><description>The purpose of this longitudinal prospective randomized study was to evaluate the reliability of two different types of orthodontic retainers in clinical use: a multistrand stainless steel wire and a polyethylene ribbon-reinforced resin composite. Moreover the level of satisfaction of the patient about the esthetic result was also analyzed by means of a Visual Analogue Scale (VAS). 34 patients (9 boys and 25 girls, mean age 14.3), in the finishing phase of orthodontic treatment, were selected for the study. Since splints were applied the number, cause, and date of splint failures were recorded for each single tooth over 12 months. Statistical analysis was performed using a paired t-test, Kaplan Meier survival estimates, and the log-rank test. Kruskal Wallis test was performed to analyze VAS recordings. Differences between the bond failure rates were not statistically significant. Esthetic result of VAS was significantly higher for polyethylene ribbon-reinforced resin retainers than for stainless steel wires.</description><identifier>ISSN: 1687-8728</identifier><identifier>EISSN: 1687-8736</identifier><identifier>DOI: 10.1155/2011/548356</identifier><identifier>PMID: 22114597</identifier><language>eng</language><publisher>Cairo, Egypt: Hindawi Limiteds</publisher><subject>Clinical Study</subject><ispartof>International Journal of Dentistry, 2011-01, Vol.2011 (2011), p.180-184</ispartof><rights>Copyright © 2011 Andrea Scribante et al.</rights><rights>Copyright © 2011 Andrea Scribante et al. 2011</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-a572t-23b94bf4597d8a2c0f5ddf74e9e4ef2d13bf7b4cbc8ae4b6a03c7b77de9cbb483</citedby><cites>FETCH-LOGICAL-a572t-23b94bf4597d8a2c0f5ddf74e9e4ef2d13bf7b4cbc8ae4b6a03c7b77de9cbb483</cites><orcidid>0000-0003-3445-3289 ; 0000-0002-2760-0124</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC3205661/pdf/$$EPDF$$P50$$Gpubmedcentral$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC3205661/$$EHTML$$P50$$Gpubmedcentral$$Hfree_for_read</linktohtml><link.rule.ids>230,314,727,780,784,885,27924,27925,37013,53791,53793</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/22114597$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><contributor>Ariji, Eiichiro</contributor><creatorcontrib>Scribante, Andrea</creatorcontrib><creatorcontrib>Sfondrini, Maria Francesca</creatorcontrib><creatorcontrib>Broggini, Simona</creatorcontrib><creatorcontrib>D'Allocco, Marina</creatorcontrib><creatorcontrib>Gandini, Paola</creatorcontrib><title>Efficacy of Esthetic Retainers: Clinical Comparison between Multistranded Wires and Direct-Bond Glass Fiber-Reinforced Composite Splints</title><title>International Journal of Dentistry</title><addtitle>Int J Dent</addtitle><description>The purpose of this longitudinal prospective randomized study was to evaluate the reliability of two different types of orthodontic retainers in clinical use: a multistrand stainless steel wire and a polyethylene ribbon-reinforced resin composite. Moreover the level of satisfaction of the patient about the esthetic result was also analyzed by means of a Visual Analogue Scale (VAS). 34 patients (9 boys and 25 girls, mean age 14.3), in the finishing phase of orthodontic treatment, were selected for the study. Since splints were applied the number, cause, and date of splint failures were recorded for each single tooth over 12 months. Statistical analysis was performed using a paired t-test, Kaplan Meier survival estimates, and the log-rank test. Kruskal Wallis test was performed to analyze VAS recordings. Differences between the bond failure rates were not statistically significant. Esthetic result of VAS was significantly higher for polyethylene ribbon-reinforced resin retainers than for stainless steel wires.</description><subject>Clinical Study</subject><issn>1687-8728</issn><issn>1687-8736</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2011</creationdate><recordtype>article</recordtype><sourceid>DOA</sourceid><recordid>eNqFkk1v1DAQQCMEolXpiTPINyRQqL-T5VAJlm2ptAhUQBwt2xl3XWXjxfZS9R_ws3GaZaEncvHYfnrjzExVPSX4NSFCnFBMyIngLRPyQXVIZNvUbcPkw31M24PqOKVrXD5GuCDycXVAKSnhrDmsfi2c81bbWxQcWqS8guwtuoSs_QAxvUHz3g8F6NE8rDc6-hQGZCDfAAzo47bPPuWohw469N1HSKjE6H2JbK7fhRKf9zoldOYNxPoS_OBCtAUebSH5DOjLpmTI6Un1yOk-wfFuPaq-nS2-zj_Uy0_nF_O3y1qLhuaaMjPjxo2P71pNLXai61zDYQYcHO0IM64x3BrbauBGasxsY5qmg5k1ptTpqLqYvF3Q12oT_VrHWxW0V3cHIV4pHUsNelCWGXCEykYC5dgSo1umhWAcS0a04MV1Ork2W7OGzsJQatHfk96_GfxKXYWfilEspCRF8GIniOHHFlJWa58s9L0eIGyTmmFJBC-tKuSribQxpBTB7bMQrMZJUOMkqGkSCv3834ft2T99L8DLCVj5odM3_j-2ZxMMBQGn9zBvsRDjXyyne-2jz15dh20cSg_V52KRWFCJMb8zEjouDaalnruzvxvSltwtZ78BGmDb9Q</recordid><startdate>20110101</startdate><enddate>20110101</enddate><creator>Scribante, Andrea</creator><creator>Sfondrini, Maria Francesca</creator><creator>Broggini, Simona</creator><creator>D'Allocco, Marina</creator><creator>Gandini, Paola</creator><general>Hindawi Limiteds</general><general>Hindawi Puplishing Corporation</general><general>Hindawi Publishing Corporation</general><general>Hindawi Limited</general><scope>188</scope><scope>ADJCN</scope><scope>AHFXO</scope><scope>RHU</scope><scope>RHW</scope><scope>RHX</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>5PM</scope><scope>DOA</scope><orcidid>https://orcid.org/0000-0003-3445-3289</orcidid><orcidid>https://orcid.org/0000-0002-2760-0124</orcidid></search><sort><creationdate>20110101</creationdate><title>Efficacy of Esthetic Retainers: Clinical Comparison between Multistranded Wires and Direct-Bond Glass Fiber-Reinforced Composite Splints</title><author>Scribante, Andrea ; Sfondrini, Maria Francesca ; Broggini, Simona ; D'Allocco, Marina ; Gandini, Paola</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-a572t-23b94bf4597d8a2c0f5ddf74e9e4ef2d13bf7b4cbc8ae4b6a03c7b77de9cbb483</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2011</creationdate><topic>Clinical Study</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Scribante, Andrea</creatorcontrib><creatorcontrib>Sfondrini, Maria Francesca</creatorcontrib><creatorcontrib>Broggini, Simona</creatorcontrib><creatorcontrib>D'Allocco, Marina</creatorcontrib><creatorcontrib>Gandini, Paola</creatorcontrib><collection>Airiti Library</collection><collection>الدوريات العلمية والإحصائية - e-Marefa Academic and Statistical Periodicals</collection><collection>معرفة - المحتوى العربي الأكاديمي المتكامل - e-Marefa Academic Complete</collection><collection>Hindawi Publishing Complete</collection><collection>Hindawi Publishing Subscription Journals</collection><collection>Hindawi Publishing Open Access</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><collection>Directory of Open Access Journals</collection><jtitle>International Journal of Dentistry</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Scribante, Andrea</au><au>Sfondrini, Maria Francesca</au><au>Broggini, Simona</au><au>D'Allocco, Marina</au><au>Gandini, Paola</au><au>Ariji, Eiichiro</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Efficacy of Esthetic Retainers: Clinical Comparison between Multistranded Wires and Direct-Bond Glass Fiber-Reinforced Composite Splints</atitle><jtitle>International Journal of Dentistry</jtitle><addtitle>Int J Dent</addtitle><date>2011-01-01</date><risdate>2011</risdate><volume>2011</volume><issue>2011</issue><spage>180</spage><epage>184</epage><pages>180-184</pages><issn>1687-8728</issn><eissn>1687-8736</eissn><abstract>The purpose of this longitudinal prospective randomized study was to evaluate the reliability of two different types of orthodontic retainers in clinical use: a multistrand stainless steel wire and a polyethylene ribbon-reinforced resin composite. Moreover the level of satisfaction of the patient about the esthetic result was also analyzed by means of a Visual Analogue Scale (VAS). 34 patients (9 boys and 25 girls, mean age 14.3), in the finishing phase of orthodontic treatment, were selected for the study. Since splints were applied the number, cause, and date of splint failures were recorded for each single tooth over 12 months. Statistical analysis was performed using a paired t-test, Kaplan Meier survival estimates, and the log-rank test. Kruskal Wallis test was performed to analyze VAS recordings. Differences between the bond failure rates were not statistically significant. Esthetic result of VAS was significantly higher for polyethylene ribbon-reinforced resin retainers than for stainless steel wires.</abstract><cop>Cairo, Egypt</cop><pub>Hindawi Limiteds</pub><pmid>22114597</pmid><doi>10.1155/2011/548356</doi><tpages>5</tpages><orcidid>https://orcid.org/0000-0003-3445-3289</orcidid><orcidid>https://orcid.org/0000-0002-2760-0124</orcidid><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1687-8728 |
ispartof | International Journal of Dentistry, 2011-01, Vol.2011 (2011), p.180-184 |
issn | 1687-8728 1687-8736 |
language | eng |
recordid | cdi_doaj_primary_oai_doaj_org_article_c3bef12676e240c1ba83a55340631a54 |
source | PubMed (Medline); Publicly Available Content Database (Proquest) (PQ_SDU_P3); Wiley Online Library Open Access |
subjects | Clinical Study |
title | Efficacy of Esthetic Retainers: Clinical Comparison between Multistranded Wires and Direct-Bond Glass Fiber-Reinforced Composite Splints |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-27T08%3A43%3A47IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_doaj_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Efficacy%20of%20Esthetic%20Retainers:%20Clinical%20Comparison%20between%20Multistranded%20Wires%20and%20Direct-Bond%20Glass%20Fiber-Reinforced%20Composite%20Splints&rft.jtitle=International%20Journal%20of%20Dentistry&rft.au=Scribante,%20Andrea&rft.date=2011-01-01&rft.volume=2011&rft.issue=2011&rft.spage=180&rft.epage=184&rft.pages=180-184&rft.issn=1687-8728&rft.eissn=1687-8736&rft_id=info:doi/10.1155/2011/548356&rft_dat=%3Cproquest_doaj_%3E906154145%3C/proquest_doaj_%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-a572t-23b94bf4597d8a2c0f5ddf74e9e4ef2d13bf7b4cbc8ae4b6a03c7b77de9cbb483%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=906154145&rft_id=info:pmid/22114597&rft_airiti_id=P20160526004_201112_201702240004_201702240004_180_184&rfr_iscdi=true |