Loading…

A novel model to correlate hydrogel spacer placement, perirectal space creation, and rectum dosimetry in prostate stereotactic body radiotherapy

The SpaceOAR hydrogel is employed to limit rectal radiation dose during prostate radiotherapy. We identified a novel parameter - the product of angle θ and hydrogel volume - to quantify hydrogel placement. This parameter predicted rectum dosimetry and acute rectal toxicity in prostate cancer patient...

Full description

Saved in:
Bibliographic Details
Published in:Radiation oncology (London, England) England), 2018-10, Vol.13 (1), p.192-192, Article 192
Main Authors: Hwang, Mark E, Black, Paul J, Elliston, Carl D, Wolthuis, Brian A, Smith, Deborah R, Wu, Cheng-Chia, Wenske, Sven, Deutsch, Israel
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:The SpaceOAR hydrogel is employed to limit rectal radiation dose during prostate radiotherapy. We identified a novel parameter - the product of angle θ and hydrogel volume - to quantify hydrogel placement. This parameter predicted rectum dosimetry and acute rectal toxicity in prostate cancer patients treated with stereotactic body radiotherapy to 36.25 Gy in 5 fractions. Twenty men with low- and intermediate-risk prostate cancer underwent hydrogel placement from 2015 to 2017. Hydrogel symmetry was assessed on the CT simulation scan in 3 axial slices (midgland, 1 cm above midgland, 1 cm below midgland). Two novel parameters quantifying hydrogel placement - hydrogel volume and angle θ formed by the prostate, hydrogel, and rectum - were measured, and the normalized product of θ and hydrogel volume calculated. These were then correlated with perirectal distance, rectum maximum 1-3 cc point doses (rD 1-3 cc), and rectum volumes receiving 80-95% of the prescription dose (rV80-95%). Acute rectal toxicity was recorded per RTOG criteria. In 50% of patients, hydrogel placement was symmetric bilaterally to within 1 cm of midline in all three CT simulation scan axial slices. Lateral hydrogel asymmetry
ISSN:1748-717X
1748-717X
DOI:10.1186/s13014-018-1135-6