Biomechanical evaluation of implant options for unilateral maxillary defects: a finite element analysis
This study aimed to evaluate stress distribution in unilateral maxillary defects using finite element analysis (FEA) to compare subperiosteal (SI) and zygomatic implants (ZI). A 3D model of a unilaterally atrophied maxilla was reconstructed from CT scans. Five scenarios were simulated: (1) quad zygo...
Saved in:
Published in: | BMC oral health 2024-11, Vol.24 (1), p.1338-14, Article 1338 |
---|---|
Main Authors: | , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | This study aimed to evaluate stress distribution in unilateral maxillary defects using finite element analysis (FEA) to compare subperiosteal (SI) and zygomatic implants (ZI).
A 3D model of a unilaterally atrophied maxilla was reconstructed from CT scans. Five scenarios were simulated: (1) quad zygoma implants (SC1), (2) zygoma and conventional implants (SC2), (3) two-piece SI and conventional implants (SC3), (4) one-piece SI and conventional implants (SC4) and (5) one-piece SI implant (SC5). Mechanical properties were assigned based on data in the literature; a 450 N force for occlusal loading and a 93 N force for oblique loads were applied.
Under vertical loading, SC2 exhibited the highest tensile stress (Pmax) in the atrophic region (R-AM), while SC4 showed the lowest Pmax across the entire maxilla, indicating better stress distribution. Under oblique forces, SC2 also showed the highest Pmax in R-AM, while SC5 had the lowest Pmax overall. Minimum principal stress (Pmin) followed similar patterns, with SC4 and SC5 demonstrating lower stress levels than the other scenarios. Abutment stresses were highest in SC2 and lowest in SC4. Overall, the SI scenarios (SC3-SC5) exhibited lower stress transmission to the alveolar bone than the ZI scenarios (SC1 and SC2), with SC4 providing the most balanced stress distribution across all regions.
SI implants, mainly the one-piece SI (SC4), offered a more favourable stress distribution than ZI implants in unilateral maxillary defects, reducing the risk of excessive bone stress. This finding suggests that SI implants may be superior for such cases, although individual patient anatomy should guide implant selection. Further clinical studies are necessary to confirm these biomechanical findings in vivo.
This study underscores the crucial role of implant selection in minimising stress on the alveolar bone in unilateral maxillary defects. Based on these findings, we recommend personalised implant strategies based on biomechanical insights to enhance outcomes in maxillofacial reconstruction. |
---|---|