A Wireless Gamma-Ray Monitoring System for Cemented Radwaste Drums

In the framework of the PREDIS EU project, a wireless battery-operated gamma-ray detection system was developed in order to provide a medium-to-long-term monitoring system for radioactive waste drums. It was initially proposed to monitor the gamma radioactivity outcoming from steel drums containing...

Full description

Saved in:
Bibliographic Details
Published in:Sensors (Basel, Switzerland) Switzerland), 2024-04, Vol.24 (7), p.2332
Main Authors: Romoli, Mauro, Di Giovanni, Michele, Di Meo, Paolo, Pandalone, Antonio, Principe, Claudio, Sabbarese, Carlo, D'Onofrio, Antonio, Prchal, Karel, Záruba, Jakub, Finocchiaro, Paolo
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites cdi_FETCH-LOGICAL-c413t-dce1f92a4f7ee5e8df709cb3c265f46c123e2e2e60e7f7b3d20ea800ac8a78543
container_end_page
container_issue 7
container_start_page 2332
container_title Sensors (Basel, Switzerland)
container_volume 24
creator Romoli, Mauro
Di Giovanni, Michele
Di Meo, Paolo
Pandalone, Antonio
Principe, Claudio
Sabbarese, Carlo
D'Onofrio, Antonio
Prchal, Karel
Záruba, Jakub
Finocchiaro, Paolo
description In the framework of the PREDIS EU project, a wireless battery-operated gamma-ray detection system was developed in order to provide a medium-to-long-term monitoring system for radioactive waste drums. It was initially proposed to monitor the gamma radioactivity outcoming from steel drums containing cemented radwaste, even though it could be usefully employed in a wider range of applications. Gamma rays are penetrating and convey information from the drum's internal structure, as the count rate measured on the surface depends on the thickness and density of the crossed materials. A number of sensors arranged around a drum, typically four units, provide indications of the emission anisotropy, and any sensitive change in the measured count rate would hint at some anomaly, thus triggering a suitable inspection by operators.
doi_str_mv 10.3390/s24072332
format article
fullrecord <record><control><sourceid>gale_doaj_</sourceid><recordid>TN_cdi_doaj_primary_oai_doaj_org_article_d35552c6a3414ec6859cfe8ecf0a2ad6</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><galeid>A790021392</galeid><doaj_id>oai_doaj_org_article_d35552c6a3414ec6859cfe8ecf0a2ad6</doaj_id><sourcerecordid>A790021392</sourcerecordid><originalsourceid>FETCH-LOGICAL-c413t-dce1f92a4f7ee5e8df709cb3c265f46c123e2e2e60e7f7b3d20ea800ac8a78543</originalsourceid><addsrcrecordid>eNpdkUGLFDEQhYMo7rp68A9Igxc99JpOpTvp4-yo68KKsCoem5qkMmTodNakG5l_b8ZZB5E6JDy-elXFY-xlwy8Bev4uC8mVABCP2Hkjhay1EPzxP_8z9iznHeeFAf2UnYHuGt5KOGdXq-qHTzRSztU1hoD1He6rz3Hyc0x-2lZf93mmULmYqjUFmmay1R3aX1jk6n1aQn7OnjgcM714eC_Y948fvq0_1bdfrm_Wq9vayAbm2hpqXC9QOkXUkrZO8d5swIiudbIzjQASpTpOyqkNWMEJNedoNCpdlr1gN0dfG3E33CcfMO2HiH74I8S0HTDN3ow0WGjbVpgOQTaSTKfb3jjSZBxHgbYrXm-OXvcp_lwoz0Pw2dA44kRxyQNw0BJ0r6Cgr_9Dd3FJU7n0QKkOeM8P1OWR2mKZ7ycX54SmlKXgTZzI-aKvVF9CaKAXpeHtscGkmHMid7qo4cMh1eGUamFfPaywbALZE_k3RvgNcqWZ4g</addsrcrecordid><sourcetype>Open Website</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>3037630903</pqid></control><display><type>article</type><title>A Wireless Gamma-Ray Monitoring System for Cemented Radwaste Drums</title><source>ProQuest - Publicly Available Content Database</source><source>PubMed Central</source><creator>Romoli, Mauro ; Di Giovanni, Michele ; Di Meo, Paolo ; Pandalone, Antonio ; Principe, Claudio ; Sabbarese, Carlo ; D'Onofrio, Antonio ; Prchal, Karel ; Záruba, Jakub ; Finocchiaro, Paolo</creator><creatorcontrib>Romoli, Mauro ; Di Giovanni, Michele ; Di Meo, Paolo ; Pandalone, Antonio ; Principe, Claudio ; Sabbarese, Carlo ; D'Onofrio, Antonio ; Prchal, Karel ; Záruba, Jakub ; Finocchiaro, Paolo</creatorcontrib><description>In the framework of the PREDIS EU project, a wireless battery-operated gamma-ray detection system was developed in order to provide a medium-to-long-term monitoring system for radioactive waste drums. It was initially proposed to monitor the gamma radioactivity outcoming from steel drums containing cemented radwaste, even though it could be usefully employed in a wider range of applications. Gamma rays are penetrating and convey information from the drum's internal structure, as the count rate measured on the surface depends on the thickness and density of the crossed materials. A number of sensors arranged around a drum, typically four units, provide indications of the emission anisotropy, and any sensitive change in the measured count rate would hint at some anomaly, thus triggering a suitable inspection by operators.</description><identifier>ISSN: 1424-8220</identifier><identifier>EISSN: 1424-8220</identifier><identifier>DOI: 10.3390/s24072332</identifier><identifier>PMID: 38610543</identifier><language>eng</language><publisher>Switzerland: MDPI AG</publisher><subject>cemented radwaste drum ; Electronics ; Gamma rays ; gamma-ray counter ; Modularity ; Radiation ; Radioactive wastes ; radwaste monitoring ; Receivers &amp; amplifiers ; Sensors ; Software ; wireless radiation sensor</subject><ispartof>Sensors (Basel, Switzerland), 2024-04, Vol.24 (7), p.2332</ispartof><rights>COPYRIGHT 2024 MDPI AG</rights><rights>2024 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c413t-dce1f92a4f7ee5e8df709cb3c265f46c123e2e2e60e7f7b3d20ea800ac8a78543</cites><orcidid>0000-0002-3088-9360 ; 0000-0001-7502-2229</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.proquest.com/docview/3037630903/fulltextPDF?pq-origsite=primo$$EPDF$$P50$$Gproquest$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.proquest.com/docview/3037630903?pq-origsite=primo$$EHTML$$P50$$Gproquest$$Hfree_for_read</linktohtml><link.rule.ids>314,780,784,25753,27924,27925,37012,37013,44590,75126</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/38610543$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Romoli, Mauro</creatorcontrib><creatorcontrib>Di Giovanni, Michele</creatorcontrib><creatorcontrib>Di Meo, Paolo</creatorcontrib><creatorcontrib>Pandalone, Antonio</creatorcontrib><creatorcontrib>Principe, Claudio</creatorcontrib><creatorcontrib>Sabbarese, Carlo</creatorcontrib><creatorcontrib>D'Onofrio, Antonio</creatorcontrib><creatorcontrib>Prchal, Karel</creatorcontrib><creatorcontrib>Záruba, Jakub</creatorcontrib><creatorcontrib>Finocchiaro, Paolo</creatorcontrib><title>A Wireless Gamma-Ray Monitoring System for Cemented Radwaste Drums</title><title>Sensors (Basel, Switzerland)</title><addtitle>Sensors (Basel)</addtitle><description>In the framework of the PREDIS EU project, a wireless battery-operated gamma-ray detection system was developed in order to provide a medium-to-long-term monitoring system for radioactive waste drums. It was initially proposed to monitor the gamma radioactivity outcoming from steel drums containing cemented radwaste, even though it could be usefully employed in a wider range of applications. Gamma rays are penetrating and convey information from the drum's internal structure, as the count rate measured on the surface depends on the thickness and density of the crossed materials. A number of sensors arranged around a drum, typically four units, provide indications of the emission anisotropy, and any sensitive change in the measured count rate would hint at some anomaly, thus triggering a suitable inspection by operators.</description><subject>cemented radwaste drum</subject><subject>Electronics</subject><subject>Gamma rays</subject><subject>gamma-ray counter</subject><subject>Modularity</subject><subject>Radiation</subject><subject>Radioactive wastes</subject><subject>radwaste monitoring</subject><subject>Receivers &amp; amplifiers</subject><subject>Sensors</subject><subject>Software</subject><subject>wireless radiation sensor</subject><issn>1424-8220</issn><issn>1424-8220</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><sourceid>PIMPY</sourceid><sourceid>DOA</sourceid><recordid>eNpdkUGLFDEQhYMo7rp68A9Igxc99JpOpTvp4-yo68KKsCoem5qkMmTodNakG5l_b8ZZB5E6JDy-elXFY-xlwy8Bev4uC8mVABCP2Hkjhay1EPzxP_8z9iznHeeFAf2UnYHuGt5KOGdXq-qHTzRSztU1hoD1He6rz3Hyc0x-2lZf93mmULmYqjUFmmay1R3aX1jk6n1aQn7OnjgcM714eC_Y948fvq0_1bdfrm_Wq9vayAbm2hpqXC9QOkXUkrZO8d5swIiudbIzjQASpTpOyqkNWMEJNedoNCpdlr1gN0dfG3E33CcfMO2HiH74I8S0HTDN3ow0WGjbVpgOQTaSTKfb3jjSZBxHgbYrXm-OXvcp_lwoz0Pw2dA44kRxyQNw0BJ0r6Cgr_9Dd3FJU7n0QKkOeM8P1OWR2mKZ7ycX54SmlKXgTZzI-aKvVF9CaKAXpeHtscGkmHMid7qo4cMh1eGUamFfPaywbALZE_k3RvgNcqWZ4g</recordid><startdate>20240401</startdate><enddate>20240401</enddate><creator>Romoli, Mauro</creator><creator>Di Giovanni, Michele</creator><creator>Di Meo, Paolo</creator><creator>Pandalone, Antonio</creator><creator>Principe, Claudio</creator><creator>Sabbarese, Carlo</creator><creator>D'Onofrio, Antonio</creator><creator>Prchal, Karel</creator><creator>Záruba, Jakub</creator><creator>Finocchiaro, Paolo</creator><general>MDPI AG</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>3V.</scope><scope>7X7</scope><scope>7XB</scope><scope>88E</scope><scope>8FI</scope><scope>8FJ</scope><scope>8FK</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>FYUFA</scope><scope>GHDGH</scope><scope>K9.</scope><scope>M0S</scope><scope>M1P</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>7X8</scope><scope>DOA</scope><orcidid>https://orcid.org/0000-0002-3088-9360</orcidid><orcidid>https://orcid.org/0000-0001-7502-2229</orcidid></search><sort><creationdate>20240401</creationdate><title>A Wireless Gamma-Ray Monitoring System for Cemented Radwaste Drums</title><author>Romoli, Mauro ; Di Giovanni, Michele ; Di Meo, Paolo ; Pandalone, Antonio ; Principe, Claudio ; Sabbarese, Carlo ; D'Onofrio, Antonio ; Prchal, Karel ; Záruba, Jakub ; Finocchiaro, Paolo</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c413t-dce1f92a4f7ee5e8df709cb3c265f46c123e2e2e60e7f7b3d20ea800ac8a78543</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><topic>cemented radwaste drum</topic><topic>Electronics</topic><topic>Gamma rays</topic><topic>gamma-ray counter</topic><topic>Modularity</topic><topic>Radiation</topic><topic>Radioactive wastes</topic><topic>radwaste monitoring</topic><topic>Receivers &amp; amplifiers</topic><topic>Sensors</topic><topic>Software</topic><topic>wireless radiation sensor</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Romoli, Mauro</creatorcontrib><creatorcontrib>Di Giovanni, Michele</creatorcontrib><creatorcontrib>Di Meo, Paolo</creatorcontrib><creatorcontrib>Pandalone, Antonio</creatorcontrib><creatorcontrib>Principe, Claudio</creatorcontrib><creatorcontrib>Sabbarese, Carlo</creatorcontrib><creatorcontrib>D'Onofrio, Antonio</creatorcontrib><creatorcontrib>Prchal, Karel</creatorcontrib><creatorcontrib>Záruba, Jakub</creatorcontrib><creatorcontrib>Finocchiaro, Paolo</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>ProQuest Central (Corporate)</collection><collection>Health &amp; Medical Collection</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>Medical Database (Alumni Edition)</collection><collection>Hospital Premium Collection</collection><collection>Hospital Premium Collection (Alumni Edition)</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>ProQuest Central (Alumni)</collection><collection>ProQuest Central</collection><collection>ProQuest Central Essentials</collection><collection>ProQuest Central</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central Korea</collection><collection>Health Research Premium Collection</collection><collection>Health Research Premium Collection (Alumni)</collection><collection>ProQuest Health &amp; Medical Complete (Alumni)</collection><collection>Health &amp; Medical Collection (Alumni Edition)</collection><collection>Medical Database</collection><collection>ProQuest - Publicly Available Content Database</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>MEDLINE - Academic</collection><collection>DOAJ Directory of Open Access Journals</collection><jtitle>Sensors (Basel, Switzerland)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Romoli, Mauro</au><au>Di Giovanni, Michele</au><au>Di Meo, Paolo</au><au>Pandalone, Antonio</au><au>Principe, Claudio</au><au>Sabbarese, Carlo</au><au>D'Onofrio, Antonio</au><au>Prchal, Karel</au><au>Záruba, Jakub</au><au>Finocchiaro, Paolo</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A Wireless Gamma-Ray Monitoring System for Cemented Radwaste Drums</atitle><jtitle>Sensors (Basel, Switzerland)</jtitle><addtitle>Sensors (Basel)</addtitle><date>2024-04-01</date><risdate>2024</risdate><volume>24</volume><issue>7</issue><spage>2332</spage><pages>2332-</pages><issn>1424-8220</issn><eissn>1424-8220</eissn><abstract>In the framework of the PREDIS EU project, a wireless battery-operated gamma-ray detection system was developed in order to provide a medium-to-long-term monitoring system for radioactive waste drums. It was initially proposed to monitor the gamma radioactivity outcoming from steel drums containing cemented radwaste, even though it could be usefully employed in a wider range of applications. Gamma rays are penetrating and convey information from the drum's internal structure, as the count rate measured on the surface depends on the thickness and density of the crossed materials. A number of sensors arranged around a drum, typically four units, provide indications of the emission anisotropy, and any sensitive change in the measured count rate would hint at some anomaly, thus triggering a suitable inspection by operators.</abstract><cop>Switzerland</cop><pub>MDPI AG</pub><pmid>38610543</pmid><doi>10.3390/s24072332</doi><orcidid>https://orcid.org/0000-0002-3088-9360</orcidid><orcidid>https://orcid.org/0000-0001-7502-2229</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1424-8220
ispartof Sensors (Basel, Switzerland), 2024-04, Vol.24 (7), p.2332
issn 1424-8220
1424-8220
language eng
recordid cdi_doaj_primary_oai_doaj_org_article_d35552c6a3414ec6859cfe8ecf0a2ad6
source ProQuest - Publicly Available Content Database; PubMed Central
subjects cemented radwaste drum
Electronics
Gamma rays
gamma-ray counter
Modularity
Radiation
Radioactive wastes
radwaste monitoring
Receivers & amplifiers
Sensors
Software
wireless radiation sensor
title A Wireless Gamma-Ray Monitoring System for Cemented Radwaste Drums
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-04T13%3A11%3A19IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-gale_doaj_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20Wireless%20Gamma-Ray%20Monitoring%20System%20for%20Cemented%20Radwaste%20Drums&rft.jtitle=Sensors%20(Basel,%20Switzerland)&rft.au=Romoli,%20Mauro&rft.date=2024-04-01&rft.volume=24&rft.issue=7&rft.spage=2332&rft.pages=2332-&rft.issn=1424-8220&rft.eissn=1424-8220&rft_id=info:doi/10.3390/s24072332&rft_dat=%3Cgale_doaj_%3EA790021392%3C/gale_doaj_%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c413t-dce1f92a4f7ee5e8df709cb3c265f46c123e2e2e60e7f7b3d20ea800ac8a78543%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=3037630903&rft_id=info:pmid/38610543&rft_galeid=A790021392&rfr_iscdi=true