Loading…
Monte Carlo-based dose calculation for 32 P patch source for superficial brachytherapy applications
Skin cancer treatment involving 32 P source is an easy, less expensive method of treatment limited to small and superficial lesions of approximately 1 mm deep. Bhabha Atomic Research Centre (BARC) has indigenously developed 32 P nafion-based patch source (1 cm Χ 1 cm) for treating skin cancer. For t...
Saved in:
Published in: | Journal of medical physics 2015-01, Vol.40 (1), p.13-17 |
---|---|
Main Authors: | , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Skin cancer treatment involving 32 P source is an easy, less expensive method of treatment limited to small and superficial lesions of approximately 1 mm deep. Bhabha Atomic Research Centre (BARC) has indigenously developed 32 P nafion-based patch source (1 cm Χ 1 cm) for treating skin cancer. For this source, the values of dose per unit activity at different depths including dose profiles in water are calculated using the EGSnrc-based Monte Carlo code system. For an initial activity of 1 Bq distributed in 1 cm 2 surface area of the source, the calculated central axis depth dose values are 3.62 Χ 10 -10 GyBq -1 and 8.41 Χ 10 -11 GyBq -1 at 0.0125 and 1 mm depths in water, respectively. Hence, the treatment time calculated for delivering therapeutic dose of 30 Gy at 1 mm depth along the central axis of the source involving 37 MBq activity is about 2.7 hrs. |
---|---|
ISSN: | 0971-6203 1998-3913 |
DOI: | 10.4103/0971-6203.152232 |