Introduce a method of dynamic force calibration by impact excitation. An analysis of the 200kN standard dynamic force calibration equipment at NIM is presented. The heavy hammer and the force transducer under test are brought to collision, and the impact force is measured by laser-Doppler interferom...
Saved in:
Published in: | EPJ Web of conferences 2014, Vol.77, p.8-1-00008-4 |
---|---|
Main Authors: | , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Introduce a method of dynamic force calibration by impact excitation. An analysis of the 200kN standard dynamic force calibration equipment at NIM is presented. The heavy hammer and the force transducer under test are brought to collision, and the impact force is measured by laser-Doppler interferometer. Traceability of force is realized by the determination of mass and acceleration. Two experiments were introduced and a typical example of impact process was performed. |
---|---|