Loading…
Real-time plasmid transmission detection pipeline
The spread of antimicrobial resistance among bacteria by horizontal plasmid transmissions poses a major challenge for clinical microbiology. Here, we evaluate a new real-time plasmid transmission detection pipeline implemented in the SeqSphere (Ridom GmbH, Münster, Germany) software. Within the pipe...
Saved in:
Published in: | Microbiology spectrum 2024-10, Vol.12 (12), p.e0210024 |
---|---|
Main Authors: | , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | The spread of antimicrobial resistance among bacteria by horizontal plasmid transmissions poses a major challenge for clinical microbiology. Here, we evaluate a new real-time plasmid transmission detection pipeline implemented in the SeqSphere
(Ridom GmbH, Münster, Germany) software. Within the pipeline, a local Mash plasmid database is created, and Mash searches with a distance threshold of 0.001 are used to trigger plasmid transmission early warning alerts (EWAs). Clonal transmissions are detected using core-genome multi-locus sequence typing allelic differences. The tools MOB-suite, NCBI AMRFinderPlus, CGE MobileElementFinder, pyGenomeViz, and MUMmer, integrated in SeqSphere+, are used to characterize plasmids and for visual pairwise plasmid comparisons, respectively. We evaluated the pipeline using published hybrid assemblies (Oxford Nanopore Technology/Illumina) of a surveillance and outbreak data set with plasmid transmissions. To emulate prospective usage, samples were imported in chronological order of sampling date. Different combinations of the user-adjustable parameters sketch size (1,000 vs 10,000) and plasmid size correction were tested, and discrepancies between resulting clusters were analyzed with Quast. When using a sketch size of 1,000 with size correction turned on, the SeqSphere
pipeline agreed with the published data and produced the same clonal and carbapenemase-carrying plasmid clusters. EWAs were in the correct chronological order. In summary, the developed pipeline presented here is suitable for integration into clinical microbiology settings with limited bioinformatics knowledge due to its automated analyses and alert system, which are combined with the GUI-based SeqSphere
platform. Thus, with its integrated sample database, (near) real-time plasmid transmission detection is within reach in bacterial routine-diagnostic settings when long-read sequencing is employed.
Plasmid-mediated spread of antimicrobial resistance is a major challenge for clinical microbiology, and monitoring of potential plasmid transmissions is essential to combat further dissemination. Whole-genome sequencing is often used to surveil nosocomial transmissions but usually limited to the detection of clonal transmissions (based on chromosomal markers). Recent advances in long-read sequencing technologies enable full reconstruction of plasmids and the detection of very similar plasmids, but so far, easy-to-use bioinformatic tools for this purpose have been missi |
---|---|
ISSN: | 2165-0497 2165-0497 |
DOI: | 10.1128/spectrum.02100-24 |