Electrochemistry of Freely Diffusing Mediators in Polyelectrolyte Membranes Used for Blood Glucose Test Strips with a High Upper Limit of the Linear Range
Co-immobilization of low-molecular-weight mediators and glucose oxidase in polyelectrolyte membranes results in glucose test strips operating in the millimolar concentration range. The density and charge of polyelectrolyte membranes formed on the surface of the screen-printed electrodes allow the di...
Saved in:
Published in: | Engineering proceedings 2023-05, Vol.35 (1), p.19 |
---|---|
Main Authors: | , , |
Format: | Article |
Language: | English |
Subjects: | |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | |
---|---|
cites | |
container_end_page | |
container_issue | 1 |
container_start_page | 19 |
container_title | Engineering proceedings |
container_volume | 35 |
creator | Vita Nikitina Ivan Solovyev Arkady Karyakin |
description | Co-immobilization of low-molecular-weight mediators and glucose oxidase in polyelectrolyte membranes results in glucose test strips operating in the millimolar concentration range. The density and charge of polyelectrolyte membranes formed on the surface of the screen-printed electrodes allow the diffusion of mediators to be controlled. Negatively charged perfluorosulfonated ionomer (PFSI) hampers the diffusion of the commonly used ferricyanide (III) ion, while the hexammine ruthenium (III) cation apparent diffusion coefficient in PFSI membrane remains the same as without the membrane. In contrast to PFSI, electrode modification with positively charged chitosan leads to additional adsorption of potassium hexacyanoferrate on the membrane. Additionally, the rate of mediator leakage from the membrane was found to govern the sensitivity of the resulting biosensors. The leakage rate also depends on the density and charge of the polyelectrolyte and mediator. However, the main advantage of the proposed simple approach of single-step deposition of three-component membrane-forming mixtures on the screen-printed electrodes is the extended upper limit of the linearity: 30–50 mM glucose. Hence, the obtained test strips are suitable for glucose detection in undiluted blood. |
doi_str_mv | 10.3390/IECB2023-14603 |
format | article |
fullrecord | <record><control><sourceid>doaj</sourceid><recordid>TN_cdi_doaj_primary_oai_doaj_org_article_d9e99144d1ed4ae384f628240d087c33</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><doaj_id>oai_doaj_org_article_d9e99144d1ed4ae384f628240d087c33</doaj_id><sourcerecordid>oai_doaj_org_article_d9e99144d1ed4ae384f628240d087c33</sourcerecordid><originalsourceid>FETCH-LOGICAL-d1763-9a0b1ab83d2a042351ebaa08157762310cd7a4e164fb0a3528a08bee27af077f3</originalsourceid><addsrcrecordid>eNotjd1O4zAUhKOVkBYBt3t9XiCL7ePEyeVSClTqahHbXkcn8XFrlMaVbYTyKjwt5edqNPNpZorilxS_EVtxvVoubpRQWEpdC_xRnKvaYKmrVv4srlJ6FkKoSiqNeF68LUcecgzDng8-5ThDcHAXmccZbr1zL8lPO_jL1lMOMYGf4DGMM3-1xjnzCR76SBMn2Ca24EKEmzEEC_fjyxASw4ZThv85-mOCV5_3QPDgd3vYHo8cYe0PPn-85j2fzMQU4YmmHV8WZ47GxFffelFs75abxUO5_ne_WvxZl1aaGsuWRC-pb9AqElphJbknEo2sjKkVSjFYQ5plrV0vCCvVnGDPrAw5YYzDi2L1tWsDPXfH6A8U5y6Q7z6DEHcdxeyHkTvbcttKra1kq4mx0a5WjdLCisYMiPgOYSt2oA</addsrcrecordid><sourcetype>Open Website</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Electrochemistry of Freely Diffusing Mediators in Polyelectrolyte Membranes Used for Blood Glucose Test Strips with a High Upper Limit of the Linear Range</title><source>Open Access: DOAJ - Directory of Open Access Journals</source><creator>Vita Nikitina ; Ivan Solovyev ; Arkady Karyakin</creator><creatorcontrib>Vita Nikitina ; Ivan Solovyev ; Arkady Karyakin</creatorcontrib><description>Co-immobilization of low-molecular-weight mediators and glucose oxidase in polyelectrolyte membranes results in glucose test strips operating in the millimolar concentration range. The density and charge of polyelectrolyte membranes formed on the surface of the screen-printed electrodes allow the diffusion of mediators to be controlled. Negatively charged perfluorosulfonated ionomer (PFSI) hampers the diffusion of the commonly used ferricyanide (III) ion, while the hexammine ruthenium (III) cation apparent diffusion coefficient in PFSI membrane remains the same as without the membrane. In contrast to PFSI, electrode modification with positively charged chitosan leads to additional adsorption of potassium hexacyanoferrate on the membrane. Additionally, the rate of mediator leakage from the membrane was found to govern the sensitivity of the resulting biosensors. The leakage rate also depends on the density and charge of the polyelectrolyte and mediator. However, the main advantage of the proposed simple approach of single-step deposition of three-component membrane-forming mixtures on the screen-printed electrodes is the extended upper limit of the linearity: 30–50 mM glucose. Hence, the obtained test strips are suitable for glucose detection in undiluted blood.</description><identifier>EISSN: 2673-4591</identifier><identifier>DOI: 10.3390/IECB2023-14603</identifier><language>eng</language><publisher>MDPI AG</publisher><subject>biosensor ; diffusion ; glucose ; mediator ; membrane ; test strip</subject><ispartof>Engineering proceedings, 2023-05, Vol.35 (1), p.19</ispartof><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,860,2096,27901,27902</link.rule.ids></links><search><creatorcontrib>Vita Nikitina</creatorcontrib><creatorcontrib>Ivan Solovyev</creatorcontrib><creatorcontrib>Arkady Karyakin</creatorcontrib><title>Electrochemistry of Freely Diffusing Mediators in Polyelectrolyte Membranes Used for Blood Glucose Test Strips with a High Upper Limit of the Linear Range</title><title>Engineering proceedings</title><description>Co-immobilization of low-molecular-weight mediators and glucose oxidase in polyelectrolyte membranes results in glucose test strips operating in the millimolar concentration range. The density and charge of polyelectrolyte membranes formed on the surface of the screen-printed electrodes allow the diffusion of mediators to be controlled. Negatively charged perfluorosulfonated ionomer (PFSI) hampers the diffusion of the commonly used ferricyanide (III) ion, while the hexammine ruthenium (III) cation apparent diffusion coefficient in PFSI membrane remains the same as without the membrane. In contrast to PFSI, electrode modification with positively charged chitosan leads to additional adsorption of potassium hexacyanoferrate on the membrane. Additionally, the rate of mediator leakage from the membrane was found to govern the sensitivity of the resulting biosensors. The leakage rate also depends on the density and charge of the polyelectrolyte and mediator. However, the main advantage of the proposed simple approach of single-step deposition of three-component membrane-forming mixtures on the screen-printed electrodes is the extended upper limit of the linearity: 30–50 mM glucose. Hence, the obtained test strips are suitable for glucose detection in undiluted blood.</description><subject>biosensor</subject><subject>diffusion</subject><subject>glucose</subject><subject>mediator</subject><subject>membrane</subject><subject>test strip</subject><issn>2673-4591</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2023</creationdate><recordtype>article</recordtype><sourceid>DOA</sourceid><recordid>eNotjd1O4zAUhKOVkBYBt3t9XiCL7ePEyeVSClTqahHbXkcn8XFrlMaVbYTyKjwt5edqNPNpZorilxS_EVtxvVoubpRQWEpdC_xRnKvaYKmrVv4srlJ6FkKoSiqNeF68LUcecgzDng8-5ThDcHAXmccZbr1zL8lPO_jL1lMOMYGf4DGMM3-1xjnzCR76SBMn2Ca24EKEmzEEC_fjyxASw4ZThv85-mOCV5_3QPDgd3vYHo8cYe0PPn-85j2fzMQU4YmmHV8WZ47GxFffelFs75abxUO5_ne_WvxZl1aaGsuWRC-pb9AqElphJbknEo2sjKkVSjFYQ5plrV0vCCvVnGDPrAw5YYzDi2L1tWsDPXfH6A8U5y6Q7z6DEHcdxeyHkTvbcttKra1kq4mx0a5WjdLCisYMiPgOYSt2oA</recordid><startdate>20230501</startdate><enddate>20230501</enddate><creator>Vita Nikitina</creator><creator>Ivan Solovyev</creator><creator>Arkady Karyakin</creator><general>MDPI AG</general><scope>DOA</scope></search><sort><creationdate>20230501</creationdate><title>Electrochemistry of Freely Diffusing Mediators in Polyelectrolyte Membranes Used for Blood Glucose Test Strips with a High Upper Limit of the Linear Range</title><author>Vita Nikitina ; Ivan Solovyev ; Arkady Karyakin</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-d1763-9a0b1ab83d2a042351ebaa08157762310cd7a4e164fb0a3528a08bee27af077f3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2023</creationdate><topic>biosensor</topic><topic>diffusion</topic><topic>glucose</topic><topic>mediator</topic><topic>membrane</topic><topic>test strip</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Vita Nikitina</creatorcontrib><creatorcontrib>Ivan Solovyev</creatorcontrib><creatorcontrib>Arkady Karyakin</creatorcontrib><collection>Open Access: DOAJ - Directory of Open Access Journals</collection><jtitle>Engineering proceedings</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Vita Nikitina</au><au>Ivan Solovyev</au><au>Arkady Karyakin</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Electrochemistry of Freely Diffusing Mediators in Polyelectrolyte Membranes Used for Blood Glucose Test Strips with a High Upper Limit of the Linear Range</atitle><jtitle>Engineering proceedings</jtitle><date>2023-05-01</date><risdate>2023</risdate><volume>35</volume><issue>1</issue><spage>19</spage><pages>19-</pages><eissn>2673-4591</eissn><abstract>Co-immobilization of low-molecular-weight mediators and glucose oxidase in polyelectrolyte membranes results in glucose test strips operating in the millimolar concentration range. The density and charge of polyelectrolyte membranes formed on the surface of the screen-printed electrodes allow the diffusion of mediators to be controlled. Negatively charged perfluorosulfonated ionomer (PFSI) hampers the diffusion of the commonly used ferricyanide (III) ion, while the hexammine ruthenium (III) cation apparent diffusion coefficient in PFSI membrane remains the same as without the membrane. In contrast to PFSI, electrode modification with positively charged chitosan leads to additional adsorption of potassium hexacyanoferrate on the membrane. Additionally, the rate of mediator leakage from the membrane was found to govern the sensitivity of the resulting biosensors. The leakage rate also depends on the density and charge of the polyelectrolyte and mediator. However, the main advantage of the proposed simple approach of single-step deposition of three-component membrane-forming mixtures on the screen-printed electrodes is the extended upper limit of the linearity: 30–50 mM glucose. Hence, the obtained test strips are suitable for glucose detection in undiluted blood.</abstract><pub>MDPI AG</pub><doi>10.3390/IECB2023-14603</doi><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | EISSN: 2673-4591 |
ispartof | Engineering proceedings, 2023-05, Vol.35 (1), p.19 |
issn | 2673-4591 |
language | eng |
recordid | cdi_doaj_primary_oai_doaj_org_article_d9e99144d1ed4ae384f628240d087c33 |
source | Open Access: DOAJ - Directory of Open Access Journals |
subjects | biosensor diffusion glucose mediator membrane test strip |
title | Electrochemistry of Freely Diffusing Mediators in Polyelectrolyte Membranes Used for Blood Glucose Test Strips with a High Upper Limit of the Linear Range |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-08T11%3A03%3A09IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-doaj&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Electrochemistry%20of%20Freely%20Diffusing%20Mediators%20in%20Polyelectrolyte%20Membranes%20Used%20for%20Blood%20Glucose%20Test%20Strips%20with%20a%20High%20Upper%20Limit%20of%20the%20Linear%20Range&rft.jtitle=Engineering%20proceedings&rft.au=Vita%20Nikitina&rft.date=2023-05-01&rft.volume=35&rft.issue=1&rft.spage=19&rft.pages=19-&rft.eissn=2673-4591&rft_id=info:doi/10.3390/IECB2023-14603&rft_dat=%3Cdoaj%3Eoai_doaj_org_article_d9e99144d1ed4ae384f628240d087c33%3C/doaj%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-d1763-9a0b1ab83d2a042351ebaa08157762310cd7a4e164fb0a3528a08bee27af077f3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true |