Loading…
Design of a novel lateral mass screw-plate system for the treatment of unstable atlas fractures: a finite element analysis
Osteosynthesis of unstable atlas fractures preserves joint motion and therefore has a distinct advantage over a range of treatment procedures. To prevent the potential disadvantages associated with osteosynthesis, a new atlas lateral mass screw-plate (LMSP) system has been designed. However, the bio...
Saved in:
Published in: | Journal of orthopaedic surgery and research 2024-02, Vol.19 (1), p.120-120, Article 120 |
---|---|
Main Authors: | , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Osteosynthesis of unstable atlas fractures preserves joint motion and therefore has a distinct advantage over a range of treatment procedures. To prevent the potential disadvantages associated with osteosynthesis, a new atlas lateral mass screw-plate (LMSP) system has been designed. However, the biomechanical role of using the LMSP system in atlas internal fixation is not known. The aim of this study was to compare the biomechanical stability of a new LMSP with traditional posterior screw and rod (PSR) fixation techniques on the occipitocervical junction (C0-C2) through finite element analysis.
A nonlinear C0-C2 finite element model of the intact upper cervical spine was developed and validated. The unstable model using the PSR system was then compared with the model using the LMSP system for fixation. A vertical load of 40 N was applied to the C0 to simulate head weight, while a torque of 1.5 Nm was applied to the C0 to simulate flexion, extension, lateral bending, and axial rotation.
The range of motion of both systems was close to the intact model. Compared with the LMSP system model, the PSR system model increased flexion, extension, lateral bending, and axial rotation by 4.9%, 3.0%, 5.0%, and 29.5% in the C0-C1 segments, and 4.9%, 2.7%, 2.4%, and 22.6% in the C1-C2, respectively. In flexion, extension, and lateral bending motion, the LMSP system model exhibited similar stress to the PSR system model, while in axial rotation, the PSR system model exhibited higher stress.
The findings of our study indicate that the two tested system models provide comparable stability. However, better stability was achieved during axial rotation with the LMSP system, and in this system, the maximum von Mises stress was less than that of the PSR one. As the atlantoaxial joint functions primarily as a rotational joint, the use of the LMSP system may provide a more stable environment for the joint that has become unstable due to fracture. |
---|---|
ISSN: | 1749-799X 1749-799X |
DOI: | 10.1186/s13018-024-04582-6 |