Experimental Study of Perfobond Rib Shear Connector under Lateral Force
A series of full-scale pushed out tests were performed on the Perfobond rib shear connector. The tests were designed to examine the performance of the Perfobond rib shear connector under different rib hole sizes and shapes, reinforcing bar sizes, rib thicknesses, as well as the presence of lateral f...
Saved in:
Published in: | Applied sciences 2021-10, Vol.11 (19), p.9088 |
---|---|
Main Authors: | , , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | A series of full-scale pushed out tests were performed on the Perfobond rib shear connector. The tests were designed to examine the performance of the Perfobond rib shear connector under different rib hole sizes and shapes, reinforcing bar sizes, rib thicknesses, as well as the presence of lateral forces. It has been revealed from the test results that the rib hole size and reinforcement diameter may not act independently, and the influence of one’s size is actually dependent on the size of the other one. The lateral forces also affect the performance of the shear connector; for example, the capacity of the shear connector would be larger under compression than under tension. The existence of transverse pretension stress accelerated the cracking of concrete, leading to the strength and stiffness of concrete, perforated plate, and reinforcing rebars unable to fully exert their effect. In addition, the constraint effect of transverse stress improved the strength and stiffness of concrete and delayed the concrete cracking, bringing the strength and stiffness of concrete, perforated plate, and reinforcing rebars into full play, and resulting in a significant improvement in the shear capacity of Perfobond rib shear connectors. |
---|---|
ISSN: | 2076-3417 2076-3417 |
DOI: | 10.3390/app11199088 |