Loading…
Late Results of Cox Maze III Procedure in Patients with Atrial Fibrillation Associated with Structural Heart Disease
Cox-Maze III procedure is one of the surgical techniques used in the surgical treatment of atrial fibrillation (AF). To determine late results of Cox-Maze III in terms of maintenance of sinus rhythm, and mortality and stroke rates. Between January 2006 and January 2013, 93 patients were submitted to...
Saved in:
Published in: | Arquivos brasileiros de cardiologia 2017-07, Vol.109 (1), p.14-22 |
---|---|
Main Authors: | , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Cox-Maze III procedure is one of the surgical techniques used in the surgical treatment of atrial fibrillation (AF).
To determine late results of Cox-Maze III in terms of maintenance of sinus rhythm, and mortality and stroke rates.
Between January 2006 and January 2013, 93 patients were submitted to the cut-and-sew Cox-Maze III procedure in combination with structural heart disease repair. Heart rhythm was determined by 24-hour Holter monitoring. Procedural success rates were determined by longitudinal methods and recurrence predictors by multivariate Cox regression models.
Thirteen patients that obtained hospital discharge alive were excluded due to lost follow-up. The remaining 80 patients were aged 49.9 ± 12 years and 47 (58.7%) of them were female. Involvement of mitral valve and rheumatic heart disease were found in 67 (83.7%) and 63 (78.7%) patients, respectively. Seventy patients (87.5%) had persistent or long-standing persistent AF. Mean follow-up with Holter monitoring was 27.5 months. There were no hospital deaths. Sinus rhythm maintenance rates were 88%, 85.1% and 80.6% at 6 months, 24 months and 36 months, respectively. Predictors of late recurrence of AF were female gender (HR 3.52; 95% CI 1.21-10.25; p = 0.02), coronary artery disease (HR 4.73 95% CI 1.37-16.36; p = 0.01) and greater left atrium diameter (HR 1.05; 95% CI 1.01-1.09; p = 0.02). Actuarial survival was 98.5% at 12, 24 and 48 months and actuarial freedom from stroke was 100%, 100% and 97.5% in the same time frames.
The Cox-Maze III procedure, in our experience, is efficacious for sinus rhythm maintenance, with very low late mortality and stroke rates.
A operação de Cox-Maze III é uma das variantes técnicas no tratamento cirúrgico da fibrilação atrial (FA).
Estudar os resultados tardios da operação de Cox-Maze III, quanto à eficácia na manutenção de ritmo sinusal e taxas de mortalidade e acidente vascular cerebral (AVC).
Entre janeiro de 2006 a janeiro de 2013, 93 pacientes foram submetidos a operação de Cox-Maze III por corte e sutura associada a correção de cardiopatias estruturais. Avaliação do ritmo cardíaco ocorreu por Holter 24 horas. Taxas de sucesso da operação foram estudadas por métodos longitudinais e os preditores de recorrência por análise de regressão de Cox multivariada.
Foram excluídos 13 pacientes sobreviventes ao período intra-hospitalar cujo seguimento tardio não foi possível. Os 80 pacientes restantes tinham idade média de 49,9 ± 12 anos e 47 (58,75%) eram do se |
---|---|
ISSN: | 0066-782X 1678-4170 1678-4170 |
DOI: | 10.5935/abc.20170082 |