Loading…

Inspection for Voids in the Grout below the Protective Duct of an External Post-Tensioning Bridge Tendon Using a THz A-Scanner

Grout voids in the tendons of a post-tensioning bridge reduce their strength. Grout voids are also severe flaws causing corrosion of the steel strands in the tendons. Detecting voids during construction and operation of the tendons is essential to prevent tendon failure, which is critical to bridge...

Full description

Saved in:
Bibliographic Details
Published in:Applied sciences 2023-11, Vol.13 (22), p.12119
Main Authors: Yee, Dae-Su, Yahng, Ji Sang, Cho, Seung Hyun
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites cdi_FETCH-LOGICAL-c363t-19e237bd1c892f984f4ca83dcc60bcc0eaa3fb50695c53fdb8d5b80b1e65f9043
container_end_page
container_issue 22
container_start_page 12119
container_title Applied sciences
container_volume 13
creator Yee, Dae-Su
Yahng, Ji Sang
Cho, Seung Hyun
description Grout voids in the tendons of a post-tensioning bridge reduce their strength. Grout voids are also severe flaws causing corrosion of the steel strands in the tendons. Detecting voids during construction and operation of the tendons is essential to prevent tendon failure, which is critical to bridge safety. This study presents a method for inspecting external tendons for voids in the grout below the protective duct pipe using terahertz electromagnetic waves. Due to low attenuation in the high-density polyethylene duct and the large reflectivity difference between the duct/grout and the duct/void interfaces, terahertz waves are suitable for detecting voids in the grout inside tendons. For this study, we developed a mobile frequency-domain terahertz A-scanner that can be used to measure terahertz A-scan data in real time. It is shown that the mobile terahertz A-scanner can be used to assess the area of the grout void in external bridge tendons.
doi_str_mv 10.3390/app132212119
format article
fullrecord <record><control><sourceid>gale_doaj_</sourceid><recordid>TN_cdi_doaj_primary_oai_doaj_org_article_dd59f29967bd40eea2115ec589c83db0</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><galeid>A774316694</galeid><doaj_id>oai_doaj_org_article_dd59f29967bd40eea2115ec589c83db0</doaj_id><sourcerecordid>A774316694</sourcerecordid><originalsourceid>FETCH-LOGICAL-c363t-19e237bd1c892f984f4ca83dcc60bcc0eaa3fb50695c53fdb8d5b80b1e65f9043</originalsourceid><addsrcrecordid>eNpNkUtvGyEUhUdVK9VKsusPQMo2k8IwL5aOmyaWItVSnG4Rc7m4WDZMAPeRRX57mLiKAgvg6PDdo3uL4gujl5wL-lWNI-NVxSrGxIdiVtGuLXnNuo_v7p-Lsxi3NC_BeM_orHheujgiJOsdMT6Qn97qSKwj6ReSm-APiQy4839e36vg0-T9jeTbARLxhihHrv8mDE7tyMrHVK7RxQyzbkOugtUbJFnRmf4QJ02R9e0TmZf3oJzDcFp8MmoX8ez_eVI8fL9eL27Lux83y8X8rgTe8lQygRXvBs2gF5URfW1qUD3XAC0dACgqxc3Q0FY00HCjh143Q08Hhm1jBK35SbE8crVXWzkGu1fhn_TKylfBh41UIVnYodS6EaYSos31aoqockMbhKYXkCsONLPOj6wx-McDxiS3_jA1IMoqxxNd3bE-uy6Pro3KUOuMT0FB3hr3FrxDY7M-77qas7YVU8SL4wcIPsaA5i0mo3KasHw_Yf4Cm-2Ynw</addsrcrecordid><sourcetype>Open Website</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2892974718</pqid></control><display><type>article</type><title>Inspection for Voids in the Grout below the Protective Duct of an External Post-Tensioning Bridge Tendon Using a THz A-Scanner</title><source>Publicly Available Content Database</source><creator>Yee, Dae-Su ; Yahng, Ji Sang ; Cho, Seung Hyun</creator><creatorcontrib>Yee, Dae-Su ; Yahng, Ji Sang ; Cho, Seung Hyun</creatorcontrib><description>Grout voids in the tendons of a post-tensioning bridge reduce their strength. Grout voids are also severe flaws causing corrosion of the steel strands in the tendons. Detecting voids during construction and operation of the tendons is essential to prevent tendon failure, which is critical to bridge safety. This study presents a method for inspecting external tendons for voids in the grout below the protective duct pipe using terahertz electromagnetic waves. Due to low attenuation in the high-density polyethylene duct and the large reflectivity difference between the duct/grout and the duct/void interfaces, terahertz waves are suitable for detecting voids in the grout inside tendons. For this study, we developed a mobile frequency-domain terahertz A-scanner that can be used to measure terahertz A-scan data in real time. It is shown that the mobile terahertz A-scanner can be used to assess the area of the grout void in external bridge tendons.</description><identifier>ISSN: 2076-3417</identifier><identifier>EISSN: 2076-3417</identifier><identifier>DOI: 10.3390/app132212119</identifier><language>eng</language><publisher>Basel: MDPI AG</publisher><subject>Bridges ; Corrosion ; Electric waves ; Electromagnetic radiation ; Electromagnetic waves ; Electromagnetism ; external tendon ; Fourier transforms ; Heat ; High density polyethylenes ; Lasers ; Methods ; nondestructive inspection ; Nondestructive testing ; post-tensioning bridge ; Radiation ; Radiography ; Scanners ; Spectrum analysis ; Steel ; terahertz wave ; Tomography ; voids in grout</subject><ispartof>Applied sciences, 2023-11, Vol.13 (22), p.12119</ispartof><rights>COPYRIGHT 2023 MDPI AG</rights><rights>2023 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c363t-19e237bd1c892f984f4ca83dcc60bcc0eaa3fb50695c53fdb8d5b80b1e65f9043</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.proquest.com/docview/2892974718/fulltextPDF?pq-origsite=primo$$EPDF$$P50$$Gproquest$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.proquest.com/docview/2892974718?pq-origsite=primo$$EHTML$$P50$$Gproquest$$Hfree_for_read</linktohtml><link.rule.ids>314,780,784,25753,27924,27925,37012,44590,74998</link.rule.ids></links><search><creatorcontrib>Yee, Dae-Su</creatorcontrib><creatorcontrib>Yahng, Ji Sang</creatorcontrib><creatorcontrib>Cho, Seung Hyun</creatorcontrib><title>Inspection for Voids in the Grout below the Protective Duct of an External Post-Tensioning Bridge Tendon Using a THz A-Scanner</title><title>Applied sciences</title><description>Grout voids in the tendons of a post-tensioning bridge reduce their strength. Grout voids are also severe flaws causing corrosion of the steel strands in the tendons. Detecting voids during construction and operation of the tendons is essential to prevent tendon failure, which is critical to bridge safety. This study presents a method for inspecting external tendons for voids in the grout below the protective duct pipe using terahertz electromagnetic waves. Due to low attenuation in the high-density polyethylene duct and the large reflectivity difference between the duct/grout and the duct/void interfaces, terahertz waves are suitable for detecting voids in the grout inside tendons. For this study, we developed a mobile frequency-domain terahertz A-scanner that can be used to measure terahertz A-scan data in real time. It is shown that the mobile terahertz A-scanner can be used to assess the area of the grout void in external bridge tendons.</description><subject>Bridges</subject><subject>Corrosion</subject><subject>Electric waves</subject><subject>Electromagnetic radiation</subject><subject>Electromagnetic waves</subject><subject>Electromagnetism</subject><subject>external tendon</subject><subject>Fourier transforms</subject><subject>Heat</subject><subject>High density polyethylenes</subject><subject>Lasers</subject><subject>Methods</subject><subject>nondestructive inspection</subject><subject>Nondestructive testing</subject><subject>post-tensioning bridge</subject><subject>Radiation</subject><subject>Radiography</subject><subject>Scanners</subject><subject>Spectrum analysis</subject><subject>Steel</subject><subject>terahertz wave</subject><subject>Tomography</subject><subject>voids in grout</subject><issn>2076-3417</issn><issn>2076-3417</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2023</creationdate><recordtype>article</recordtype><sourceid>PIMPY</sourceid><sourceid>DOA</sourceid><recordid>eNpNkUtvGyEUhUdVK9VKsusPQMo2k8IwL5aOmyaWItVSnG4Rc7m4WDZMAPeRRX57mLiKAgvg6PDdo3uL4gujl5wL-lWNI-NVxSrGxIdiVtGuLXnNuo_v7p-Lsxi3NC_BeM_orHheujgiJOsdMT6Qn97qSKwj6ReSm-APiQy4839e36vg0-T9jeTbARLxhihHrv8mDE7tyMrHVK7RxQyzbkOugtUbJFnRmf4QJ02R9e0TmZf3oJzDcFp8MmoX8ez_eVI8fL9eL27Lux83y8X8rgTe8lQygRXvBs2gF5URfW1qUD3XAC0dACgqxc3Q0FY00HCjh143Q08Hhm1jBK35SbE8crVXWzkGu1fhn_TKylfBh41UIVnYodS6EaYSos31aoqockMbhKYXkCsONLPOj6wx-McDxiS3_jA1IMoqxxNd3bE-uy6Pro3KUOuMT0FB3hr3FrxDY7M-77qas7YVU8SL4wcIPsaA5i0mo3KasHw_Yf4Cm-2Ynw</recordid><startdate>20231101</startdate><enddate>20231101</enddate><creator>Yee, Dae-Su</creator><creator>Yahng, Ji Sang</creator><creator>Cho, Seung Hyun</creator><general>MDPI AG</general><scope>AAYXX</scope><scope>CITATION</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>DOA</scope></search><sort><creationdate>20231101</creationdate><title>Inspection for Voids in the Grout below the Protective Duct of an External Post-Tensioning Bridge Tendon Using a THz A-Scanner</title><author>Yee, Dae-Su ; Yahng, Ji Sang ; Cho, Seung Hyun</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c363t-19e237bd1c892f984f4ca83dcc60bcc0eaa3fb50695c53fdb8d5b80b1e65f9043</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2023</creationdate><topic>Bridges</topic><topic>Corrosion</topic><topic>Electric waves</topic><topic>Electromagnetic radiation</topic><topic>Electromagnetic waves</topic><topic>Electromagnetism</topic><topic>external tendon</topic><topic>Fourier transforms</topic><topic>Heat</topic><topic>High density polyethylenes</topic><topic>Lasers</topic><topic>Methods</topic><topic>nondestructive inspection</topic><topic>Nondestructive testing</topic><topic>post-tensioning bridge</topic><topic>Radiation</topic><topic>Radiography</topic><topic>Scanners</topic><topic>Spectrum analysis</topic><topic>Steel</topic><topic>terahertz wave</topic><topic>Tomography</topic><topic>voids in grout</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Yee, Dae-Su</creatorcontrib><creatorcontrib>Yahng, Ji Sang</creatorcontrib><creatorcontrib>Cho, Seung Hyun</creatorcontrib><collection>CrossRef</collection><collection>ProQuest Central (Alumni)</collection><collection>ProQuest Central</collection><collection>ProQuest Central Essentials</collection><collection>AUTh Library subscriptions: ProQuest Central</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central</collection><collection>Publicly Available Content Database</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>DOAJ Directory of Open Access Journals</collection><jtitle>Applied sciences</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Yee, Dae-Su</au><au>Yahng, Ji Sang</au><au>Cho, Seung Hyun</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Inspection for Voids in the Grout below the Protective Duct of an External Post-Tensioning Bridge Tendon Using a THz A-Scanner</atitle><jtitle>Applied sciences</jtitle><date>2023-11-01</date><risdate>2023</risdate><volume>13</volume><issue>22</issue><spage>12119</spage><pages>12119-</pages><issn>2076-3417</issn><eissn>2076-3417</eissn><abstract>Grout voids in the tendons of a post-tensioning bridge reduce their strength. Grout voids are also severe flaws causing corrosion of the steel strands in the tendons. Detecting voids during construction and operation of the tendons is essential to prevent tendon failure, which is critical to bridge safety. This study presents a method for inspecting external tendons for voids in the grout below the protective duct pipe using terahertz electromagnetic waves. Due to low attenuation in the high-density polyethylene duct and the large reflectivity difference between the duct/grout and the duct/void interfaces, terahertz waves are suitable for detecting voids in the grout inside tendons. For this study, we developed a mobile frequency-domain terahertz A-scanner that can be used to measure terahertz A-scan data in real time. It is shown that the mobile terahertz A-scanner can be used to assess the area of the grout void in external bridge tendons.</abstract><cop>Basel</cop><pub>MDPI AG</pub><doi>10.3390/app132212119</doi><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 2076-3417
ispartof Applied sciences, 2023-11, Vol.13 (22), p.12119
issn 2076-3417
2076-3417
language eng
recordid cdi_doaj_primary_oai_doaj_org_article_dd59f29967bd40eea2115ec589c83db0
source Publicly Available Content Database
subjects Bridges
Corrosion
Electric waves
Electromagnetic radiation
Electromagnetic waves
Electromagnetism
external tendon
Fourier transforms
Heat
High density polyethylenes
Lasers
Methods
nondestructive inspection
Nondestructive testing
post-tensioning bridge
Radiation
Radiography
Scanners
Spectrum analysis
Steel
terahertz wave
Tomography
voids in grout
title Inspection for Voids in the Grout below the Protective Duct of an External Post-Tensioning Bridge Tendon Using a THz A-Scanner
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-08T00%3A04%3A37IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-gale_doaj_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Inspection%20for%20Voids%20in%20the%20Grout%20below%20the%20Protective%20Duct%20of%20an%20External%20Post-Tensioning%20Bridge%20Tendon%20Using%20a%20THz%20A-Scanner&rft.jtitle=Applied%20sciences&rft.au=Yee,%20Dae-Su&rft.date=2023-11-01&rft.volume=13&rft.issue=22&rft.spage=12119&rft.pages=12119-&rft.issn=2076-3417&rft.eissn=2076-3417&rft_id=info:doi/10.3390/app132212119&rft_dat=%3Cgale_doaj_%3EA774316694%3C/gale_doaj_%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c363t-19e237bd1c892f984f4ca83dcc60bcc0eaa3fb50695c53fdb8d5b80b1e65f9043%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2892974718&rft_id=info:pmid/&rft_galeid=A774316694&rfr_iscdi=true