Inspection for Voids in the Grout below the Protective Duct of an External Post-Tensioning Bridge Tendon Using a THz A-Scanner
Grout voids in the tendons of a post-tensioning bridge reduce their strength. Grout voids are also severe flaws causing corrosion of the steel strands in the tendons. Detecting voids during construction and operation of the tendons is essential to prevent tendon failure, which is critical to bridge...
Saved in:
Published in: | Applied sciences 2023-11, Vol.13 (22), p.12119 |
---|---|
Main Authors: | , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | |
---|---|
cites | cdi_FETCH-LOGICAL-c363t-19e237bd1c892f984f4ca83dcc60bcc0eaa3fb50695c53fdb8d5b80b1e65f9043 |
container_end_page | |
container_issue | 22 |
container_start_page | 12119 |
container_title | Applied sciences |
container_volume | 13 |
creator | Yee, Dae-Su Yahng, Ji Sang Cho, Seung Hyun |
description | Grout voids in the tendons of a post-tensioning bridge reduce their strength. Grout voids are also severe flaws causing corrosion of the steel strands in the tendons. Detecting voids during construction and operation of the tendons is essential to prevent tendon failure, which is critical to bridge safety. This study presents a method for inspecting external tendons for voids in the grout below the protective duct pipe using terahertz electromagnetic waves. Due to low attenuation in the high-density polyethylene duct and the large reflectivity difference between the duct/grout and the duct/void interfaces, terahertz waves are suitable for detecting voids in the grout inside tendons. For this study, we developed a mobile frequency-domain terahertz A-scanner that can be used to measure terahertz A-scan data in real time. It is shown that the mobile terahertz A-scanner can be used to assess the area of the grout void in external bridge tendons. |
doi_str_mv | 10.3390/app132212119 |
format | article |
fullrecord | <record><control><sourceid>gale_doaj_</sourceid><recordid>TN_cdi_doaj_primary_oai_doaj_org_article_dd59f29967bd40eea2115ec589c83db0</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><galeid>A774316694</galeid><doaj_id>oai_doaj_org_article_dd59f29967bd40eea2115ec589c83db0</doaj_id><sourcerecordid>A774316694</sourcerecordid><originalsourceid>FETCH-LOGICAL-c363t-19e237bd1c892f984f4ca83dcc60bcc0eaa3fb50695c53fdb8d5b80b1e65f9043</originalsourceid><addsrcrecordid>eNpNkUtvGyEUhUdVK9VKsusPQMo2k8IwL5aOmyaWItVSnG4Rc7m4WDZMAPeRRX57mLiKAgvg6PDdo3uL4gujl5wL-lWNI-NVxSrGxIdiVtGuLXnNuo_v7p-Lsxi3NC_BeM_orHheujgiJOsdMT6Qn97qSKwj6ReSm-APiQy4839e36vg0-T9jeTbARLxhihHrv8mDE7tyMrHVK7RxQyzbkOugtUbJFnRmf4QJ02R9e0TmZf3oJzDcFp8MmoX8ez_eVI8fL9eL27Lux83y8X8rgTe8lQygRXvBs2gF5URfW1qUD3XAC0dACgqxc3Q0FY00HCjh143Q08Hhm1jBK35SbE8crVXWzkGu1fhn_TKylfBh41UIVnYodS6EaYSos31aoqockMbhKYXkCsONLPOj6wx-McDxiS3_jA1IMoqxxNd3bE-uy6Pro3KUOuMT0FB3hr3FrxDY7M-77qas7YVU8SL4wcIPsaA5i0mo3KasHw_Yf4Cm-2Ynw</addsrcrecordid><sourcetype>Open Website</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2892974718</pqid></control><display><type>article</type><title>Inspection for Voids in the Grout below the Protective Duct of an External Post-Tensioning Bridge Tendon Using a THz A-Scanner</title><source>Publicly Available Content Database</source><creator>Yee, Dae-Su ; Yahng, Ji Sang ; Cho, Seung Hyun</creator><creatorcontrib>Yee, Dae-Su ; Yahng, Ji Sang ; Cho, Seung Hyun</creatorcontrib><description>Grout voids in the tendons of a post-tensioning bridge reduce their strength. Grout voids are also severe flaws causing corrosion of the steel strands in the tendons. Detecting voids during construction and operation of the tendons is essential to prevent tendon failure, which is critical to bridge safety. This study presents a method for inspecting external tendons for voids in the grout below the protective duct pipe using terahertz electromagnetic waves. Due to low attenuation in the high-density polyethylene duct and the large reflectivity difference between the duct/grout and the duct/void interfaces, terahertz waves are suitable for detecting voids in the grout inside tendons. For this study, we developed a mobile frequency-domain terahertz A-scanner that can be used to measure terahertz A-scan data in real time. It is shown that the mobile terahertz A-scanner can be used to assess the area of the grout void in external bridge tendons.</description><identifier>ISSN: 2076-3417</identifier><identifier>EISSN: 2076-3417</identifier><identifier>DOI: 10.3390/app132212119</identifier><language>eng</language><publisher>Basel: MDPI AG</publisher><subject>Bridges ; Corrosion ; Electric waves ; Electromagnetic radiation ; Electromagnetic waves ; Electromagnetism ; external tendon ; Fourier transforms ; Heat ; High density polyethylenes ; Lasers ; Methods ; nondestructive inspection ; Nondestructive testing ; post-tensioning bridge ; Radiation ; Radiography ; Scanners ; Spectrum analysis ; Steel ; terahertz wave ; Tomography ; voids in grout</subject><ispartof>Applied sciences, 2023-11, Vol.13 (22), p.12119</ispartof><rights>COPYRIGHT 2023 MDPI AG</rights><rights>2023 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c363t-19e237bd1c892f984f4ca83dcc60bcc0eaa3fb50695c53fdb8d5b80b1e65f9043</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.proquest.com/docview/2892974718/fulltextPDF?pq-origsite=primo$$EPDF$$P50$$Gproquest$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.proquest.com/docview/2892974718?pq-origsite=primo$$EHTML$$P50$$Gproquest$$Hfree_for_read</linktohtml><link.rule.ids>314,780,784,25753,27924,27925,37012,44590,74998</link.rule.ids></links><search><creatorcontrib>Yee, Dae-Su</creatorcontrib><creatorcontrib>Yahng, Ji Sang</creatorcontrib><creatorcontrib>Cho, Seung Hyun</creatorcontrib><title>Inspection for Voids in the Grout below the Protective Duct of an External Post-Tensioning Bridge Tendon Using a THz A-Scanner</title><title>Applied sciences</title><description>Grout voids in the tendons of a post-tensioning bridge reduce their strength. Grout voids are also severe flaws causing corrosion of the steel strands in the tendons. Detecting voids during construction and operation of the tendons is essential to prevent tendon failure, which is critical to bridge safety. This study presents a method for inspecting external tendons for voids in the grout below the protective duct pipe using terahertz electromagnetic waves. Due to low attenuation in the high-density polyethylene duct and the large reflectivity difference between the duct/grout and the duct/void interfaces, terahertz waves are suitable for detecting voids in the grout inside tendons. For this study, we developed a mobile frequency-domain terahertz A-scanner that can be used to measure terahertz A-scan data in real time. It is shown that the mobile terahertz A-scanner can be used to assess the area of the grout void in external bridge tendons.</description><subject>Bridges</subject><subject>Corrosion</subject><subject>Electric waves</subject><subject>Electromagnetic radiation</subject><subject>Electromagnetic waves</subject><subject>Electromagnetism</subject><subject>external tendon</subject><subject>Fourier transforms</subject><subject>Heat</subject><subject>High density polyethylenes</subject><subject>Lasers</subject><subject>Methods</subject><subject>nondestructive inspection</subject><subject>Nondestructive testing</subject><subject>post-tensioning bridge</subject><subject>Radiation</subject><subject>Radiography</subject><subject>Scanners</subject><subject>Spectrum analysis</subject><subject>Steel</subject><subject>terahertz wave</subject><subject>Tomography</subject><subject>voids in grout</subject><issn>2076-3417</issn><issn>2076-3417</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2023</creationdate><recordtype>article</recordtype><sourceid>PIMPY</sourceid><sourceid>DOA</sourceid><recordid>eNpNkUtvGyEUhUdVK9VKsusPQMo2k8IwL5aOmyaWItVSnG4Rc7m4WDZMAPeRRX57mLiKAgvg6PDdo3uL4gujl5wL-lWNI-NVxSrGxIdiVtGuLXnNuo_v7p-Lsxi3NC_BeM_orHheujgiJOsdMT6Qn97qSKwj6ReSm-APiQy4839e36vg0-T9jeTbARLxhihHrv8mDE7tyMrHVK7RxQyzbkOugtUbJFnRmf4QJ02R9e0TmZf3oJzDcFp8MmoX8ez_eVI8fL9eL27Lux83y8X8rgTe8lQygRXvBs2gF5URfW1qUD3XAC0dACgqxc3Q0FY00HCjh143Q08Hhm1jBK35SbE8crVXWzkGu1fhn_TKylfBh41UIVnYodS6EaYSos31aoqockMbhKYXkCsONLPOj6wx-McDxiS3_jA1IMoqxxNd3bE-uy6Pro3KUOuMT0FB3hr3FrxDY7M-77qas7YVU8SL4wcIPsaA5i0mo3KasHw_Yf4Cm-2Ynw</recordid><startdate>20231101</startdate><enddate>20231101</enddate><creator>Yee, Dae-Su</creator><creator>Yahng, Ji Sang</creator><creator>Cho, Seung Hyun</creator><general>MDPI AG</general><scope>AAYXX</scope><scope>CITATION</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>DOA</scope></search><sort><creationdate>20231101</creationdate><title>Inspection for Voids in the Grout below the Protective Duct of an External Post-Tensioning Bridge Tendon Using a THz A-Scanner</title><author>Yee, Dae-Su ; Yahng, Ji Sang ; Cho, Seung Hyun</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c363t-19e237bd1c892f984f4ca83dcc60bcc0eaa3fb50695c53fdb8d5b80b1e65f9043</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2023</creationdate><topic>Bridges</topic><topic>Corrosion</topic><topic>Electric waves</topic><topic>Electromagnetic radiation</topic><topic>Electromagnetic waves</topic><topic>Electromagnetism</topic><topic>external tendon</topic><topic>Fourier transforms</topic><topic>Heat</topic><topic>High density polyethylenes</topic><topic>Lasers</topic><topic>Methods</topic><topic>nondestructive inspection</topic><topic>Nondestructive testing</topic><topic>post-tensioning bridge</topic><topic>Radiation</topic><topic>Radiography</topic><topic>Scanners</topic><topic>Spectrum analysis</topic><topic>Steel</topic><topic>terahertz wave</topic><topic>Tomography</topic><topic>voids in grout</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Yee, Dae-Su</creatorcontrib><creatorcontrib>Yahng, Ji Sang</creatorcontrib><creatorcontrib>Cho, Seung Hyun</creatorcontrib><collection>CrossRef</collection><collection>ProQuest Central (Alumni)</collection><collection>ProQuest Central</collection><collection>ProQuest Central Essentials</collection><collection>AUTh Library subscriptions: ProQuest Central</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central</collection><collection>Publicly Available Content Database</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>DOAJ Directory of Open Access Journals</collection><jtitle>Applied sciences</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Yee, Dae-Su</au><au>Yahng, Ji Sang</au><au>Cho, Seung Hyun</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Inspection for Voids in the Grout below the Protective Duct of an External Post-Tensioning Bridge Tendon Using a THz A-Scanner</atitle><jtitle>Applied sciences</jtitle><date>2023-11-01</date><risdate>2023</risdate><volume>13</volume><issue>22</issue><spage>12119</spage><pages>12119-</pages><issn>2076-3417</issn><eissn>2076-3417</eissn><abstract>Grout voids in the tendons of a post-tensioning bridge reduce their strength. Grout voids are also severe flaws causing corrosion of the steel strands in the tendons. Detecting voids during construction and operation of the tendons is essential to prevent tendon failure, which is critical to bridge safety. This study presents a method for inspecting external tendons for voids in the grout below the protective duct pipe using terahertz electromagnetic waves. Due to low attenuation in the high-density polyethylene duct and the large reflectivity difference between the duct/grout and the duct/void interfaces, terahertz waves are suitable for detecting voids in the grout inside tendons. For this study, we developed a mobile frequency-domain terahertz A-scanner that can be used to measure terahertz A-scan data in real time. It is shown that the mobile terahertz A-scanner can be used to assess the area of the grout void in external bridge tendons.</abstract><cop>Basel</cop><pub>MDPI AG</pub><doi>10.3390/app132212119</doi><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 2076-3417 |
ispartof | Applied sciences, 2023-11, Vol.13 (22), p.12119 |
issn | 2076-3417 2076-3417 |
language | eng |
recordid | cdi_doaj_primary_oai_doaj_org_article_dd59f29967bd40eea2115ec589c83db0 |
source | Publicly Available Content Database |
subjects | Bridges Corrosion Electric waves Electromagnetic radiation Electromagnetic waves Electromagnetism external tendon Fourier transforms Heat High density polyethylenes Lasers Methods nondestructive inspection Nondestructive testing post-tensioning bridge Radiation Radiography Scanners Spectrum analysis Steel terahertz wave Tomography voids in grout |
title | Inspection for Voids in the Grout below the Protective Duct of an External Post-Tensioning Bridge Tendon Using a THz A-Scanner |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-08T00%3A04%3A37IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-gale_doaj_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Inspection%20for%20Voids%20in%20the%20Grout%20below%20the%20Protective%20Duct%20of%20an%20External%20Post-Tensioning%20Bridge%20Tendon%20Using%20a%20THz%20A-Scanner&rft.jtitle=Applied%20sciences&rft.au=Yee,%20Dae-Su&rft.date=2023-11-01&rft.volume=13&rft.issue=22&rft.spage=12119&rft.pages=12119-&rft.issn=2076-3417&rft.eissn=2076-3417&rft_id=info:doi/10.3390/app132212119&rft_dat=%3Cgale_doaj_%3EA774316694%3C/gale_doaj_%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c363t-19e237bd1c892f984f4ca83dcc60bcc0eaa3fb50695c53fdb8d5b80b1e65f9043%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2892974718&rft_id=info:pmid/&rft_galeid=A774316694&rfr_iscdi=true |