Loading…

Evaluating natural gas emissions from pneumatic controllers from upstream oil and gas facilities in West Virginia

In April of 2018, an optical gas imaging (OGI) and full flow sampler (FFS) emissions measurement study of pneumatic controllers (PCs) was conducted at 15 oil and natural gas production sites in West Virginia. The objective of the study was to identify and characterize PC systems with excessive emiss...

Full description

Saved in:
Bibliographic Details
Published in:Atmospheric Environment: X 2023-01, Vol.17, p.1-10, Article 100199
Main Authors: Footer, Tracey L., Thoma, Eben D., Clark, Nigel, Johnson, Derek, Nash, Jennifer, Herndon, Scott C.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:In April of 2018, an optical gas imaging (OGI) and full flow sampler (FFS) emissions measurement study of pneumatic controllers (PCs) was conducted at 15 oil and natural gas production sites in West Virginia. The objective of the study was to identify and characterize PC systems with excessive emissions caused by maintenance issues or nonoptimized process conditions. A total of 391 PC systems were found on the sites and all were classified by the operator as snap-acting (on/off) intermittent venting PCs (IPCs) that should exhibit little gas release while the PC is closed between actuation events. The population was comprised of two groups, 259 infrequently actuating, lower emitting (LE) IPCs and 132 gas processing unit (GPU) liquid level IPCs and associated dump valve actuators that vent more frequently and have larger emission volumes. Using a PC-specific OGI inspection protocol with an assumed whole gas OGI detection threshold of 2.0 scfh, only 2 out of 259 LE-IPCs exhibited OGI detectable emissions indicating good inspection and maintenance practices for this category. Due to combined (ganged) GPU exhaust vents, the OGI inspection of the GPU liquid level IPCs was comparatively less informative and determination of single component IPC emissions by the FFS was more difficult. The time resolved FFS measurements of GPU IPCs defined three categories of operation: one that indicated proper function and two associated with higher emissions that may result from an IPC maintenance or process issues. The overall GPU IPC emission distribution was heavy tailed, with a median value of 12.8 scfh, similar to the 13.5 scfh whole gas IPC emission factor (EF). Total emissions were dominated by non-optimal temporal profile high-emitter IPC cases with the top 20% of IPC systems accounting for between 51.3% and 70.7% of GPU liquid level IPC emissions by volume. The uncertainty in the estimate was due to the ganged nature of the GPU exhaust vents. The highest GPU IPC emission came from a single malfunctioning unit with a measured whole gas value of 157 scfh. Up to six IPCs exceeded 100 scfh. An analysis of FFS emission measurements compared to liquids production per IPC unit employed indicated that production sites operating at a high level of liquids production test the limits of the site engineering, likely resulting in higher IPC emissions. Overall, this study found that the LE-IPCs with OGI-verified low closed bleed rates may emit well below the IPC EF while GPU liquid
ISSN:2590-1621
2590-1621
DOI:10.1016/j.aeaoa.2022.100199