Loading…

Dual-Modality X-Ray-Induced Radiation Acoustic and Ultrasound Imaging for Real-Time Monitoring of Radiotherapy

Objective . The goal is to increase the precision of radiation delivery during radiotherapy by tracking the movements of the tumor and other surrounding normal tissues due to respiratory and other body motions. Introduction . This work presents the recent advancement of X-ray-induced radiation acous...

Full description

Saved in:
Bibliographic Details
Published in:BME frontiers 2020-01, Vol.2020, p.9853609-9853609
Main Authors: Zhang, Wei, Oraiqat, Ibrahim, Lei, Hao, Carson, Paul L., EI Naqa, Issam, Wang, Xueding
Format: Article
Language:English
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Objective . The goal is to increase the precision of radiation delivery during radiotherapy by tracking the movements of the tumor and other surrounding normal tissues due to respiratory and other body motions. Introduction . This work presents the recent advancement of X-ray-induced radiation acoustic imaging (xRAI) technology and the evaluation of its feasibility for real-time monitoring of geometric and morphological misalignments of the X-ray field with respect to the target tissue by combining xRAI with established ultrasound (US) imaging, thereby improving radiotherapy tumor eradication and limiting treatment side effects. Methods . An integrated xRAI and B-mode US dual-modality system was established based on a clinic-ready research US platform. The performance of this dual-modality imaging system was evaluated via experiments on phantoms and ex vivo and in vivo rabbit liver models. Results . This system can alternatively switch between the xRAI and the US modes, with spatial resolutions of 1.1 mm and 0.37 mm, respectively. 300 times signal averaging was required for xRAI to reach a satisfactory signal-to-noise ratio, and a frame rate of 1.1 Hz was achieved with a clinical linear accelerator. The US imaging frame rate was 22 Hz, which is sufficient for real-time monitoring of the displacement of the target due to internal body motion. Conclusion . Our developed xRAI, in combination with US imaging, allows for mapping of the dose deposition in biological samples in vivo , in real-time, during radiotherapy. Impact Statement . The US-based image-guided radiotherapy system presented in this work holds great potential for personalized cancer treatment and better outcomes.
ISSN:2765-8031
2765-8031
DOI:10.34133/2020/9853609