Loading…
Incremental shuttle walk test performed in a hallway and on a treadmill: are they interchangeable?
ABSTRACT The performances of healthy individuals in an incremental shuttle walking test performed in a hallway (ISWT-H) and on a treadmill (ISWT-T) were compared to assess their physiological responses during aerobic training sessions with the speeds estimated from both tests. This was a cross-secti...
Saved in:
Published in: | Fisioterapia e pesquisa 2018-12, Vol.25 (4), p.395-403 |
---|---|
Main Authors: | , , , , , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | ABSTRACT The performances of healthy individuals in an incremental shuttle walking test performed in a hallway (ISWT-H) and on a treadmill (ISWT-T) were compared to assess their physiological responses during aerobic training sessions with the speeds estimated from both tests. This was a cross-sectional study with 55 healthy subjects, who were randomized to perform the ISWT tests with 24 hours between them. Training sessions were held using a treadmill at 75% of the speeds obtained from the ISWT-H and ISWT-T. Measurements included walking distance, oxygen uptake (VO2), carbon dioxide (VCO2) production, heart rate (HR), and ventilation (VE). There was a significant difference between walking distances (ISWT-T: 823.9±165.2 m and ISWT-H:685.4±141.4 m), but similar physiological responses for VO2 (28.6±6.6 vs. 29.0±7.3 ml-1.kg-1.min-1), VCO2 (1.9±0.7 vs. 1.9±0.5 1), HR (158.3±17.8 vs. 158.6±17.7 bpm), and VE (41.5±10.4 vs. 43.7±12.9 1). The estimated speeds were different for the training sessions (5.5±0.5 km/h and 4.9±0.3 km/h), as well as the VO2, VCO2, VE, and HR. It was concluded that in healthy young adults, ISWTs carried out in a hallway and on a treadmill are not interchangeable. Since the ISWT-H was determined to have lower speed, the training intensity based on this test may underestimate a patient’s responses to aerobic training.
RESUMEN Se trata de una comparación del rendimiento en la prueba incremental shuttle walk llevado a cabo en el pasillo (SWPI-P) y en la cinta caminadora (SWPC) entre individuos sanos, para evaluar las respuestas fisiológicas durante las sesiones de entrenamiento aeróbico con velocidades estimadas en ambas pruebas. Estudio transversal con 55 individuos sanos. A los participantes se les eligieron al azar para realizar las pruebas con intervalo de 24 horas. Se llevaron a cabo sesiones de entrenamiento en la cinta caminadora con el 75 % de la velocidad obtenida en SWPI-P y en SWPC. Se incluyen entre las evaluaciones la distancia de la caminata, el consumo de oxígeno (VO2), la producción de dióxido de carbono (VCO2), la frecuencia cardiaca (FC) y la ventilación (VE). Hubo una diferencia significativa entre las distancias recorridas (SWPC: 823,9 ± 165,2 m y SWPI-P: 685,4 ± 141,4 m), pero similares a las respuestas fisiológicas del VO2 (28,6 ± 6,6 vs. 29,0 ± 7,3 ml-1.kg-1. min-1), VCO2 (1,9 ± 0,7 vs. ± 1,9 0,5 1), HR (158,3 ± 17,8 vs. 158,6 ± 17,7 bpm) y VE (41,5 ± 10,4 vs. 43,7 ± 12,9 1). Las velocidades estimadas fueron diferente |
---|---|
ISSN: | 1809-2950 2316-9117 2316-9117 |
DOI: | 10.1590/1809-2950/17008125042018 |