Loading…

Simultaneous Determination of Eight Alkaloids in Rat Plasma by UHPLC-MS/MS after Oral Administration of Coptis deltoidea C. Y. Cheng et Hsiao and Coptis chinensis Franch

A ultra-high performance liquid chromatography-electrospray ionization tandem mass spectrometry (UHPLC-ESI-MS/MS) method was successfully developed and validated for the identification and determination of eight alkaloids: tetrahydropalmatine (A); palmatine (B); magnoflorine (C); columbamine (D); be...

Full description

Saved in:
Bibliographic Details
Published in:Molecules (Basel, Switzerland) Switzerland), 2016-07, Vol.21 (7), p.913
Main Authors: Liu, Lu, Wang, Zhi-Bin, Song, Yang, Yang, Jing, Wu, Li-Jun, Yang, Bing-You, Wang, Qiu-Hong, Wang, Li-Qian, Wang, Ru-Xuan, Yang, Chun-Juan
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:A ultra-high performance liquid chromatography-electrospray ionization tandem mass spectrometry (UHPLC-ESI-MS/MS) method was successfully developed and validated for the identification and determination of eight alkaloids: tetrahydropalmatine (A); palmatine (B); magnoflorine (C); columbamine (D); berberine (E); worenine (F); berberrubine (G) and coptisine (H) in rat plasma, which are the active components in Coptis deltoidea C. Y. cheng et Hsiao (CCY) and Coptis chinensis Franch (CF). The chromatographic separation of analytes was successfully achieved on an Agilent SB-C18 column (1.8 µm, 150 mm × 2.1 mm) using a programme with a mobile phase consisting of acetonitrile and water containing 0.3% acetic acid at a flow rate of 0.25 mL/min. The analytes were detected with a triple quadrupole tandem MS in multiple reaction monitoring (MRM) mode and an electrospray ionization (ESI) source in positive mode. The validated method showed good linearity over a wide concentration range (r² > 0.991), and lower limits of quantification (LLOQ) less than 1.1 ng/mL for all analytes, and matrix effects ranged from 85.2% to 106.8%. The mean extraction recoveries were no less than 86.4%, and the precision and accuracy were within the acceptable limits. All analytes were proven to be stable during sample storage and analysis procedures. The method validation results demonstrated that the proposed method was sensitive, specific, and reliable, which could lay a foundation for the pharmacokinetic study of eight analytes after oral administration of CCY and CF in subsequent studies.
ISSN:1420-3049
1420-3049
DOI:10.3390/molecules21070913