A Microfluidic Deformability Assessment of Pathological Red Blood Cells Flowing in a Hyperbolic Converging Microchannel

The loss of the red blood cells (RBCs) deformability is related with many human diseases, such as malaria, hereditary spherocytosis, sickle cell disease, or renal diseases. Hence, during the last years, a variety of technologies have been proposed to gain insights into the factors affecting the RBCs...

Full description

Saved in:
Bibliographic Details
Published in:Micromachines (Basel) 2019-09, Vol.10 (10), p.645
Main Authors: Faustino, Vera, Rodrigues, Raquel O., Pinho, Diana, Costa, Elísio, Santos-Silva, Alice, Miranda, Vasco, Amaral, Joana S., Lima, Rui
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c541t-cc2505fd9a33e8dc329e555a37ceb9c6e07902e83aabfb46b49094e8b65ff5543
cites cdi_FETCH-LOGICAL-c541t-cc2505fd9a33e8dc329e555a37ceb9c6e07902e83aabfb46b49094e8b65ff5543
container_end_page
container_issue 10
container_start_page 645
container_title Micromachines (Basel)
container_volume 10
creator Faustino, Vera
Rodrigues, Raquel O.
Pinho, Diana
Costa, Elísio
Santos-Silva, Alice
Miranda, Vasco
Amaral, Joana S.
Lima, Rui
description The loss of the red blood cells (RBCs) deformability is related with many human diseases, such as malaria, hereditary spherocytosis, sickle cell disease, or renal diseases. Hence, during the last years, a variety of technologies have been proposed to gain insights into the factors affecting the RBCs deformability and their possible direct association with several blood pathologies. In this work, we present a simple microfluidic tool that provides the assessment of motions and deformations of RBCs of end-stage kidney disease (ESKD) patients, under a well-controlled microenvironment. All of the flow studies were performed within a hyperbolic converging microchannels where single-cell deformability was assessed under a controlled homogeneous extensional flow field. By using a passive microfluidic device, RBCs passing through a hyperbolic-shaped contraction were measured by a high-speed video microscopy system, and the velocities and deformability ratios (DR) calculated. Blood samples from 27 individuals, including seven healthy controls and 20 having ESKD with or without diabetes, were analysed. The obtained data indicates that the proposed device is able to detect changes in DR of the RBCs, allowing for distinguishing the samples from the healthy controls and the patients. Overall, the deformability of ESKD patients with and without diabetes type II is lower in comparison with the RBCs from the healthy controls, with this difference being more evident for the group of ESKD patients with diabetes. RBCs from ESKD patients without diabetes elongate on average 8% less, within the hyperbolic contraction, as compared to healthy controls; whereas, RBCs from ESKD patients with diabetes elongate on average 14% less than the healthy controls. The proposed strategy can be easily transformed into a simple and inexpensive diagnostic microfluidic system to assess blood cells deformability due to the huge progress in image processing and high-speed microvisualization technology.
doi_str_mv 10.3390/mi10100645
format article
fullrecord <record><control><sourceid>proquest_doaj_</sourceid><recordid>TN_cdi_doaj_primary_oai_doaj_org_article_e28f8f1ceed8457eadbe309184c0410b</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><doaj_id>oai_doaj_org_article_e28f8f1ceed8457eadbe309184c0410b</doaj_id><sourcerecordid>2549029765</sourcerecordid><originalsourceid>FETCH-LOGICAL-c541t-cc2505fd9a33e8dc329e555a37ceb9c6e07902e83aabfb46b49094e8b65ff5543</originalsourceid><addsrcrecordid>eNpdkt9rFDEQxxdRbKl98S8I-CLC2fzezYtwXq0tVBRR8C0k2clejuzmTPZa7r837ZVqzcMkzHz5TObLNM1rgt8zpvDZGAgmGEsunjXHFLd0IaX89fyf91FzWsoG19O2qoaXzREjQrSK0ePmdom-BJeTj7vQB4fOwac8GhtimPdoWQqUMsI0o-TRNzOvU0xDcCai79CjjzGlHq0gxoIuYroN04DChAy63G8h2xQrcJWmG8jDXem-kVubaYL4qnnhTSxw-nCfND8vPv1YXS6uv36-Wi2vF05wMi-cowIL3yvDGHS9Y1SBEMKw1oFVTgKuI1HomDHWWy4tV1hx6KwU3gvB2UlzdeD2yWz0NofR5L1OJuj7RMqDNnkOLoIG2vnOEwfQd1y0YHoLDCvScYc5wbayPhxY250doXfVlmziE-jTyhTWekg3WnacEUoq4O0DIKffOyizHkNx1T4zQdoVTalShEnc4Sp98590k3Z5qlZpKuqQVLVSVNW7g6oaW0oG__gZgvXdeui_68H-AP9ErQg</addsrcrecordid><sourcetype>Open Website</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2549029765</pqid></control><display><type>article</type><title>A Microfluidic Deformability Assessment of Pathological Red Blood Cells Flowing in a Hyperbolic Converging Microchannel</title><source>Publicly Available Content Database</source><source>PubMed Central</source><creator>Faustino, Vera ; Rodrigues, Raquel O. ; Pinho, Diana ; Costa, Elísio ; Santos-Silva, Alice ; Miranda, Vasco ; Amaral, Joana S. ; Lima, Rui</creator><creatorcontrib>Faustino, Vera ; Rodrigues, Raquel O. ; Pinho, Diana ; Costa, Elísio ; Santos-Silva, Alice ; Miranda, Vasco ; Amaral, Joana S. ; Lima, Rui</creatorcontrib><description>The loss of the red blood cells (RBCs) deformability is related with many human diseases, such as malaria, hereditary spherocytosis, sickle cell disease, or renal diseases. Hence, during the last years, a variety of technologies have been proposed to gain insights into the factors affecting the RBCs deformability and their possible direct association with several blood pathologies. In this work, we present a simple microfluidic tool that provides the assessment of motions and deformations of RBCs of end-stage kidney disease (ESKD) patients, under a well-controlled microenvironment. All of the flow studies were performed within a hyperbolic converging microchannels where single-cell deformability was assessed under a controlled homogeneous extensional flow field. By using a passive microfluidic device, RBCs passing through a hyperbolic-shaped contraction were measured by a high-speed video microscopy system, and the velocities and deformability ratios (DR) calculated. Blood samples from 27 individuals, including seven healthy controls and 20 having ESKD with or without diabetes, were analysed. The obtained data indicates that the proposed device is able to detect changes in DR of the RBCs, allowing for distinguishing the samples from the healthy controls and the patients. Overall, the deformability of ESKD patients with and without diabetes type II is lower in comparison with the RBCs from the healthy controls, with this difference being more evident for the group of ESKD patients with diabetes. RBCs from ESKD patients without diabetes elongate on average 8% less, within the hyperbolic contraction, as compared to healthy controls; whereas, RBCs from ESKD patients with diabetes elongate on average 14% less than the healthy controls. The proposed strategy can be easily transformed into a simple and inexpensive diagnostic microfluidic system to assess blood cells deformability due to the huge progress in image processing and high-speed microvisualization technology.</description><identifier>ISSN: 2072-666X</identifier><identifier>EISSN: 2072-666X</identifier><identifier>DOI: 10.3390/mi10100645</identifier><identifier>PMID: 31557932</identifier><language>eng</language><publisher>Basel: MDPI AG</publisher><subject>Blood ; Blood diseases ; blood on chips ; cell deformability ; chronic renal disease ; Convergence ; Deformation ; Diabetes ; Elongation ; Erythrocytes ; Formability ; Geometry ; Hemodialysis ; High speed ; hyperbolic microchannel ; Image processing ; Kidney diseases ; Malaria ; Mechanical properties ; Microchannels ; Microfluidic devices ; red blood cells (rbcs) ; Rheology ; Velocity</subject><ispartof>Micromachines (Basel), 2019-09, Vol.10 (10), p.645</ispartof><rights>2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.</rights><rights>2019 by the authors. 2019</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c541t-cc2505fd9a33e8dc329e555a37ceb9c6e07902e83aabfb46b49094e8b65ff5543</citedby><cites>FETCH-LOGICAL-c541t-cc2505fd9a33e8dc329e555a37ceb9c6e07902e83aabfb46b49094e8b65ff5543</cites><orcidid>0000-0002-3648-7303 ; 0000-0001-9041-2188 ; 0000-0003-4493-2654 ; 0000-0003-3428-637X ; 0000-0002-3884-6496</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.proquest.com/docview/2549029765/fulltextPDF?pq-origsite=primo$$EPDF$$P50$$Gproquest$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.proquest.com/docview/2549029765?pq-origsite=primo$$EHTML$$P50$$Gproquest$$Hfree_for_read</linktohtml><link.rule.ids>230,314,727,780,784,885,25753,27924,27925,37012,37013,44590,53791,53793,75126</link.rule.ids></links><search><creatorcontrib>Faustino, Vera</creatorcontrib><creatorcontrib>Rodrigues, Raquel O.</creatorcontrib><creatorcontrib>Pinho, Diana</creatorcontrib><creatorcontrib>Costa, Elísio</creatorcontrib><creatorcontrib>Santos-Silva, Alice</creatorcontrib><creatorcontrib>Miranda, Vasco</creatorcontrib><creatorcontrib>Amaral, Joana S.</creatorcontrib><creatorcontrib>Lima, Rui</creatorcontrib><title>A Microfluidic Deformability Assessment of Pathological Red Blood Cells Flowing in a Hyperbolic Converging Microchannel</title><title>Micromachines (Basel)</title><description>The loss of the red blood cells (RBCs) deformability is related with many human diseases, such as malaria, hereditary spherocytosis, sickle cell disease, or renal diseases. Hence, during the last years, a variety of technologies have been proposed to gain insights into the factors affecting the RBCs deformability and their possible direct association with several blood pathologies. In this work, we present a simple microfluidic tool that provides the assessment of motions and deformations of RBCs of end-stage kidney disease (ESKD) patients, under a well-controlled microenvironment. All of the flow studies were performed within a hyperbolic converging microchannels where single-cell deformability was assessed under a controlled homogeneous extensional flow field. By using a passive microfluidic device, RBCs passing through a hyperbolic-shaped contraction were measured by a high-speed video microscopy system, and the velocities and deformability ratios (DR) calculated. Blood samples from 27 individuals, including seven healthy controls and 20 having ESKD with or without diabetes, were analysed. The obtained data indicates that the proposed device is able to detect changes in DR of the RBCs, allowing for distinguishing the samples from the healthy controls and the patients. Overall, the deformability of ESKD patients with and without diabetes type II is lower in comparison with the RBCs from the healthy controls, with this difference being more evident for the group of ESKD patients with diabetes. RBCs from ESKD patients without diabetes elongate on average 8% less, within the hyperbolic contraction, as compared to healthy controls; whereas, RBCs from ESKD patients with diabetes elongate on average 14% less than the healthy controls. The proposed strategy can be easily transformed into a simple and inexpensive diagnostic microfluidic system to assess blood cells deformability due to the huge progress in image processing and high-speed microvisualization technology.</description><subject>Blood</subject><subject>Blood diseases</subject><subject>blood on chips</subject><subject>cell deformability</subject><subject>chronic renal disease</subject><subject>Convergence</subject><subject>Deformation</subject><subject>Diabetes</subject><subject>Elongation</subject><subject>Erythrocytes</subject><subject>Formability</subject><subject>Geometry</subject><subject>Hemodialysis</subject><subject>High speed</subject><subject>hyperbolic microchannel</subject><subject>Image processing</subject><subject>Kidney diseases</subject><subject>Malaria</subject><subject>Mechanical properties</subject><subject>Microchannels</subject><subject>Microfluidic devices</subject><subject>red blood cells (rbcs)</subject><subject>Rheology</subject><subject>Velocity</subject><issn>2072-666X</issn><issn>2072-666X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2019</creationdate><recordtype>article</recordtype><sourceid>PIMPY</sourceid><sourceid>DOA</sourceid><recordid>eNpdkt9rFDEQxxdRbKl98S8I-CLC2fzezYtwXq0tVBRR8C0k2clejuzmTPZa7r837ZVqzcMkzHz5TObLNM1rgt8zpvDZGAgmGEsunjXHFLd0IaX89fyf91FzWsoG19O2qoaXzREjQrSK0ePmdom-BJeTj7vQB4fOwac8GhtimPdoWQqUMsI0o-TRNzOvU0xDcCai79CjjzGlHq0gxoIuYroN04DChAy63G8h2xQrcJWmG8jDXem-kVubaYL4qnnhTSxw-nCfND8vPv1YXS6uv36-Wi2vF05wMi-cowIL3yvDGHS9Y1SBEMKw1oFVTgKuI1HomDHWWy4tV1hx6KwU3gvB2UlzdeD2yWz0NofR5L1OJuj7RMqDNnkOLoIG2vnOEwfQd1y0YHoLDCvScYc5wbayPhxY250doXfVlmziE-jTyhTWekg3WnacEUoq4O0DIKffOyizHkNx1T4zQdoVTalShEnc4Sp98590k3Z5qlZpKuqQVLVSVNW7g6oaW0oG__gZgvXdeui_68H-AP9ErQg</recordid><startdate>20190925</startdate><enddate>20190925</enddate><creator>Faustino, Vera</creator><creator>Rodrigues, Raquel O.</creator><creator>Pinho, Diana</creator><creator>Costa, Elísio</creator><creator>Santos-Silva, Alice</creator><creator>Miranda, Vasco</creator><creator>Amaral, Joana S.</creator><creator>Lima, Rui</creator><general>MDPI AG</general><general>MDPI</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7SP</scope><scope>7TB</scope><scope>8FD</scope><scope>8FE</scope><scope>8FG</scope><scope>ABJCF</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>BGLVJ</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>FR3</scope><scope>HCIFZ</scope><scope>L6V</scope><scope>L7M</scope><scope>M7S</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>PTHSS</scope><scope>7X8</scope><scope>5PM</scope><scope>DOA</scope><orcidid>https://orcid.org/0000-0002-3648-7303</orcidid><orcidid>https://orcid.org/0000-0001-9041-2188</orcidid><orcidid>https://orcid.org/0000-0003-4493-2654</orcidid><orcidid>https://orcid.org/0000-0003-3428-637X</orcidid><orcidid>https://orcid.org/0000-0002-3884-6496</orcidid></search><sort><creationdate>20190925</creationdate><title>A Microfluidic Deformability Assessment of Pathological Red Blood Cells Flowing in a Hyperbolic Converging Microchannel</title><author>Faustino, Vera ; Rodrigues, Raquel O. ; Pinho, Diana ; Costa, Elísio ; Santos-Silva, Alice ; Miranda, Vasco ; Amaral, Joana S. ; Lima, Rui</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c541t-cc2505fd9a33e8dc329e555a37ceb9c6e07902e83aabfb46b49094e8b65ff5543</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2019</creationdate><topic>Blood</topic><topic>Blood diseases</topic><topic>blood on chips</topic><topic>cell deformability</topic><topic>chronic renal disease</topic><topic>Convergence</topic><topic>Deformation</topic><topic>Diabetes</topic><topic>Elongation</topic><topic>Erythrocytes</topic><topic>Formability</topic><topic>Geometry</topic><topic>Hemodialysis</topic><topic>High speed</topic><topic>hyperbolic microchannel</topic><topic>Image processing</topic><topic>Kidney diseases</topic><topic>Malaria</topic><topic>Mechanical properties</topic><topic>Microchannels</topic><topic>Microfluidic devices</topic><topic>red blood cells (rbcs)</topic><topic>Rheology</topic><topic>Velocity</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Faustino, Vera</creatorcontrib><creatorcontrib>Rodrigues, Raquel O.</creatorcontrib><creatorcontrib>Pinho, Diana</creatorcontrib><creatorcontrib>Costa, Elísio</creatorcontrib><creatorcontrib>Santos-Silva, Alice</creatorcontrib><creatorcontrib>Miranda, Vasco</creatorcontrib><creatorcontrib>Amaral, Joana S.</creatorcontrib><creatorcontrib>Lima, Rui</creatorcontrib><collection>CrossRef</collection><collection>Electronics &amp; Communications Abstracts</collection><collection>Mechanical &amp; Transportation Engineering Abstracts</collection><collection>Technology Research Database</collection><collection>ProQuest SciTech Collection</collection><collection>ProQuest Technology Collection</collection><collection>Materials Science &amp; Engineering Collection</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest Central UK/Ireland</collection><collection>ProQuest Central Essentials</collection><collection>ProQuest Central</collection><collection>Technology Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central Korea</collection><collection>Engineering Research Database</collection><collection>SciTech Premium Collection</collection><collection>ProQuest Engineering Collection</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>Engineering Database</collection><collection>Publicly Available Content Database</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>Engineering Collection</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><collection>DOAJ Directory of Open Access Journals</collection><jtitle>Micromachines (Basel)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Faustino, Vera</au><au>Rodrigues, Raquel O.</au><au>Pinho, Diana</au><au>Costa, Elísio</au><au>Santos-Silva, Alice</au><au>Miranda, Vasco</au><au>Amaral, Joana S.</au><au>Lima, Rui</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A Microfluidic Deformability Assessment of Pathological Red Blood Cells Flowing in a Hyperbolic Converging Microchannel</atitle><jtitle>Micromachines (Basel)</jtitle><date>2019-09-25</date><risdate>2019</risdate><volume>10</volume><issue>10</issue><spage>645</spage><pages>645-</pages><issn>2072-666X</issn><eissn>2072-666X</eissn><abstract>The loss of the red blood cells (RBCs) deformability is related with many human diseases, such as malaria, hereditary spherocytosis, sickle cell disease, or renal diseases. Hence, during the last years, a variety of technologies have been proposed to gain insights into the factors affecting the RBCs deformability and their possible direct association with several blood pathologies. In this work, we present a simple microfluidic tool that provides the assessment of motions and deformations of RBCs of end-stage kidney disease (ESKD) patients, under a well-controlled microenvironment. All of the flow studies were performed within a hyperbolic converging microchannels where single-cell deformability was assessed under a controlled homogeneous extensional flow field. By using a passive microfluidic device, RBCs passing through a hyperbolic-shaped contraction were measured by a high-speed video microscopy system, and the velocities and deformability ratios (DR) calculated. Blood samples from 27 individuals, including seven healthy controls and 20 having ESKD with or without diabetes, were analysed. The obtained data indicates that the proposed device is able to detect changes in DR of the RBCs, allowing for distinguishing the samples from the healthy controls and the patients. Overall, the deformability of ESKD patients with and without diabetes type II is lower in comparison with the RBCs from the healthy controls, with this difference being more evident for the group of ESKD patients with diabetes. RBCs from ESKD patients without diabetes elongate on average 8% less, within the hyperbolic contraction, as compared to healthy controls; whereas, RBCs from ESKD patients with diabetes elongate on average 14% less than the healthy controls. The proposed strategy can be easily transformed into a simple and inexpensive diagnostic microfluidic system to assess blood cells deformability due to the huge progress in image processing and high-speed microvisualization technology.</abstract><cop>Basel</cop><pub>MDPI AG</pub><pmid>31557932</pmid><doi>10.3390/mi10100645</doi><orcidid>https://orcid.org/0000-0002-3648-7303</orcidid><orcidid>https://orcid.org/0000-0001-9041-2188</orcidid><orcidid>https://orcid.org/0000-0003-4493-2654</orcidid><orcidid>https://orcid.org/0000-0003-3428-637X</orcidid><orcidid>https://orcid.org/0000-0002-3884-6496</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 2072-666X
ispartof Micromachines (Basel), 2019-09, Vol.10 (10), p.645
issn 2072-666X
2072-666X
language eng
recordid cdi_doaj_primary_oai_doaj_org_article_e28f8f1ceed8457eadbe309184c0410b
source Publicly Available Content Database; PubMed Central
subjects Blood
Blood diseases
blood on chips
cell deformability
chronic renal disease
Convergence
Deformation
Diabetes
Elongation
Erythrocytes
Formability
Geometry
Hemodialysis
High speed
hyperbolic microchannel
Image processing
Kidney diseases
Malaria
Mechanical properties
Microchannels
Microfluidic devices
red blood cells (rbcs)
Rheology
Velocity
title A Microfluidic Deformability Assessment of Pathological Red Blood Cells Flowing in a Hyperbolic Converging Microchannel
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-28T01%3A33%3A11IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_doaj_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20Microfluidic%20Deformability%20Assessment%20of%20Pathological%20Red%20Blood%20Cells%20Flowing%20in%20a%20Hyperbolic%20Converging%20Microchannel&rft.jtitle=Micromachines%20(Basel)&rft.au=Faustino,%20Vera&rft.date=2019-09-25&rft.volume=10&rft.issue=10&rft.spage=645&rft.pages=645-&rft.issn=2072-666X&rft.eissn=2072-666X&rft_id=info:doi/10.3390/mi10100645&rft_dat=%3Cproquest_doaj_%3E2549029765%3C/proquest_doaj_%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c541t-cc2505fd9a33e8dc329e555a37ceb9c6e07902e83aabfb46b49094e8b65ff5543%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2549029765&rft_id=info:pmid/31557932&rfr_iscdi=true