Loading…

Clinical Brain Monitoring with Time Domain NIRS: A Review and Future Perspectives

Near-infrared spectroscopy (NIRS) is an optical technique that can measure brain tissue oxygenation and haemodynamics in real-time and at the patient bedside allowing medical doctors to access important physiological information. However, despite this, the use of NIRS in a clinical environment is hi...

Full description

Saved in:
Bibliographic Details
Published in:Applied sciences 2019-04, Vol.9 (8), p.1612
Main Authors: Lange, Frédéric, Tachtsidis, Ilias
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c361t-3eecf216942a2b393ffa0b78b38ec360da5c55082ac44010dfca1ef04225c8f33
cites cdi_FETCH-LOGICAL-c361t-3eecf216942a2b393ffa0b78b38ec360da5c55082ac44010dfca1ef04225c8f33
container_end_page
container_issue 8
container_start_page 1612
container_title Applied sciences
container_volume 9
creator Lange, Frédéric
Tachtsidis, Ilias
description Near-infrared spectroscopy (NIRS) is an optical technique that can measure brain tissue oxygenation and haemodynamics in real-time and at the patient bedside allowing medical doctors to access important physiological information. However, despite this, the use of NIRS in a clinical environment is hindered due to limitations, such as poor reproducibility, lack of depth sensitivity and poor brain-specificity. Time domain NIRS (or TD-NIRS) can resolve these issues and offer detailed information of the optical properties of the tissue, allowing better physiological information to be retrieved. This is achieved at the cost of increased instrument complexity, operation complexity and price. In this review, we focus on brain monitoring clinical applications of TD-NIRS. A total of 52 publications were identified, spanning the fields of neonatal imaging, stroke assessment, traumatic brain injury (TBI) assessment, brain death assessment, psychiatry, peroperative care, neuronal disorders assessment and communication with patient with locked-in syndrome. In all the publications, the advantages of the TD-NIRS measurement to (1) extract absolute values of haemoglobin concentration and tissue oxygen saturation, (2) assess the reduced scattering coefficient, and (3) separate between extra-cerebral and cerebral tissues, are highlighted; and emphasize the utility of TD-NIRS in a clinical context. In the last sections of this review, we explore the recent developments of TD-NIRS, in terms of instrumentation and methodologies that might impact and broaden its use in the hospital.
doi_str_mv 10.3390/app9081612
format article
fullrecord <record><control><sourceid>proquest_doaj_</sourceid><recordid>TN_cdi_doaj_primary_oai_doaj_org_article_ecf69611ed414a3c849209ab68c9a20d</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><doaj_id>oai_doaj_org_article_ecf69611ed414a3c849209ab68c9a20d</doaj_id><sourcerecordid>2331407905</sourcerecordid><originalsourceid>FETCH-LOGICAL-c361t-3eecf216942a2b393ffa0b78b38ec360da5c55082ac44010dfca1ef04225c8f33</originalsourceid><addsrcrecordid>eNpNkVtLw0AQhYMoWGpf_AULvgnR2UvSrG-1Wi3UW63Py2SzqVvSbNwkLf57UyvqvMwwc_jOwAmCUwoXnEu4xKqSkNCYsoOgx2AYh1zQ4eG_-TgY1PUKupKUJxR6wcu4sKXVWJBrj7YkD660jfO2XJKtbd7Jwq4NuXHr3e1xOn-9IiMyNxtrtgTLjEzapvWGPBtfV0Y3dmPqk-Aox6I2g5_eD94mt4vxfTh7upuOR7NQ85g2ITdG54zGUjBkKZc8zxHSYZLyxHQKyDDSUQQJQy0EUMhyjdTkIBiLdJJz3g-me27mcKUqb9foP5VDq74Xzi8V-sbqwqjOKZYxpSYTVCDXiZAMJKZxoiUyyDrW2Z5VeffRmrpRK9f6sntfMc6pgKGEqFOd71Xau7r2Jv91paB2Cai_BPgXtd920Q</addsrcrecordid><sourcetype>Open Website</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2331407905</pqid></control><display><type>article</type><title>Clinical Brain Monitoring with Time Domain NIRS: A Review and Future Perspectives</title><source>Publicly Available Content Database</source><creator>Lange, Frédéric ; Tachtsidis, Ilias</creator><creatorcontrib>Lange, Frédéric ; Tachtsidis, Ilias</creatorcontrib><description>Near-infrared spectroscopy (NIRS) is an optical technique that can measure brain tissue oxygenation and haemodynamics in real-time and at the patient bedside allowing medical doctors to access important physiological information. However, despite this, the use of NIRS in a clinical environment is hindered due to limitations, such as poor reproducibility, lack of depth sensitivity and poor brain-specificity. Time domain NIRS (or TD-NIRS) can resolve these issues and offer detailed information of the optical properties of the tissue, allowing better physiological information to be retrieved. This is achieved at the cost of increased instrument complexity, operation complexity and price. In this review, we focus on brain monitoring clinical applications of TD-NIRS. A total of 52 publications were identified, spanning the fields of neonatal imaging, stroke assessment, traumatic brain injury (TBI) assessment, brain death assessment, psychiatry, peroperative care, neuronal disorders assessment and communication with patient with locked-in syndrome. In all the publications, the advantages of the TD-NIRS measurement to (1) extract absolute values of haemoglobin concentration and tissue oxygen saturation, (2) assess the reduced scattering coefficient, and (3) separate between extra-cerebral and cerebral tissues, are highlighted; and emphasize the utility of TD-NIRS in a clinical context. In the last sections of this review, we explore the recent developments of TD-NIRS, in terms of instrumentation and methodologies that might impact and broaden its use in the hospital.</description><identifier>ISSN: 2076-3417</identifier><identifier>EISSN: 2076-3417</identifier><identifier>DOI: 10.3390/app9081612</identifier><language>eng</language><publisher>Basel: MDPI AG</publisher><subject>absorption ; brain oxygenation ; diffuse optics ; NIRS ; scattering ; time-domain ; time-resolved ; tissue saturation</subject><ispartof>Applied sciences, 2019-04, Vol.9 (8), p.1612</ispartof><rights>2019. This work is licensed under https://creativecommons.org/licenses/by/4.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c361t-3eecf216942a2b393ffa0b78b38ec360da5c55082ac44010dfca1ef04225c8f33</citedby><cites>FETCH-LOGICAL-c361t-3eecf216942a2b393ffa0b78b38ec360da5c55082ac44010dfca1ef04225c8f33</cites><orcidid>0000-0002-8125-0313</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.proquest.com/docview/2331407905/fulltextPDF?pq-origsite=primo$$EPDF$$P50$$Gproquest$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.proquest.com/docview/2331407905?pq-origsite=primo$$EHTML$$P50$$Gproquest$$Hfree_for_read</linktohtml><link.rule.ids>314,780,784,25753,27924,27925,37012,44590,75126</link.rule.ids></links><search><creatorcontrib>Lange, Frédéric</creatorcontrib><creatorcontrib>Tachtsidis, Ilias</creatorcontrib><title>Clinical Brain Monitoring with Time Domain NIRS: A Review and Future Perspectives</title><title>Applied sciences</title><description>Near-infrared spectroscopy (NIRS) is an optical technique that can measure brain tissue oxygenation and haemodynamics in real-time and at the patient bedside allowing medical doctors to access important physiological information. However, despite this, the use of NIRS in a clinical environment is hindered due to limitations, such as poor reproducibility, lack of depth sensitivity and poor brain-specificity. Time domain NIRS (or TD-NIRS) can resolve these issues and offer detailed information of the optical properties of the tissue, allowing better physiological information to be retrieved. This is achieved at the cost of increased instrument complexity, operation complexity and price. In this review, we focus on brain monitoring clinical applications of TD-NIRS. A total of 52 publications were identified, spanning the fields of neonatal imaging, stroke assessment, traumatic brain injury (TBI) assessment, brain death assessment, psychiatry, peroperative care, neuronal disorders assessment and communication with patient with locked-in syndrome. In all the publications, the advantages of the TD-NIRS measurement to (1) extract absolute values of haemoglobin concentration and tissue oxygen saturation, (2) assess the reduced scattering coefficient, and (3) separate between extra-cerebral and cerebral tissues, are highlighted; and emphasize the utility of TD-NIRS in a clinical context. In the last sections of this review, we explore the recent developments of TD-NIRS, in terms of instrumentation and methodologies that might impact and broaden its use in the hospital.</description><subject>absorption</subject><subject>brain oxygenation</subject><subject>diffuse optics</subject><subject>NIRS</subject><subject>scattering</subject><subject>time-domain</subject><subject>time-resolved</subject><subject>tissue saturation</subject><issn>2076-3417</issn><issn>2076-3417</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2019</creationdate><recordtype>article</recordtype><sourceid>PIMPY</sourceid><sourceid>DOA</sourceid><recordid>eNpNkVtLw0AQhYMoWGpf_AULvgnR2UvSrG-1Wi3UW63Py2SzqVvSbNwkLf57UyvqvMwwc_jOwAmCUwoXnEu4xKqSkNCYsoOgx2AYh1zQ4eG_-TgY1PUKupKUJxR6wcu4sKXVWJBrj7YkD660jfO2XJKtbd7Jwq4NuXHr3e1xOn-9IiMyNxtrtgTLjEzapvWGPBtfV0Y3dmPqk-Aox6I2g5_eD94mt4vxfTh7upuOR7NQ85g2ITdG54zGUjBkKZc8zxHSYZLyxHQKyDDSUQQJQy0EUMhyjdTkIBiLdJJz3g-me27mcKUqb9foP5VDq74Xzi8V-sbqwqjOKZYxpSYTVCDXiZAMJKZxoiUyyDrW2Z5VeffRmrpRK9f6sntfMc6pgKGEqFOd71Xau7r2Jv91paB2Cai_BPgXtd920Q</recordid><startdate>20190401</startdate><enddate>20190401</enddate><creator>Lange, Frédéric</creator><creator>Tachtsidis, Ilias</creator><general>MDPI AG</general><scope>AAYXX</scope><scope>CITATION</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>DOA</scope><orcidid>https://orcid.org/0000-0002-8125-0313</orcidid></search><sort><creationdate>20190401</creationdate><title>Clinical Brain Monitoring with Time Domain NIRS: A Review and Future Perspectives</title><author>Lange, Frédéric ; Tachtsidis, Ilias</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c361t-3eecf216942a2b393ffa0b78b38ec360da5c55082ac44010dfca1ef04225c8f33</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2019</creationdate><topic>absorption</topic><topic>brain oxygenation</topic><topic>diffuse optics</topic><topic>NIRS</topic><topic>scattering</topic><topic>time-domain</topic><topic>time-resolved</topic><topic>tissue saturation</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Lange, Frédéric</creatorcontrib><creatorcontrib>Tachtsidis, Ilias</creatorcontrib><collection>CrossRef</collection><collection>ProQuest Central (Alumni)</collection><collection>ProQuest Central</collection><collection>ProQuest Central Essentials</collection><collection>ProQuest Central</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central</collection><collection>Publicly Available Content Database</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>Directory of Open Access Journals(OpenAccess)</collection><jtitle>Applied sciences</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Lange, Frédéric</au><au>Tachtsidis, Ilias</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Clinical Brain Monitoring with Time Domain NIRS: A Review and Future Perspectives</atitle><jtitle>Applied sciences</jtitle><date>2019-04-01</date><risdate>2019</risdate><volume>9</volume><issue>8</issue><spage>1612</spage><pages>1612-</pages><issn>2076-3417</issn><eissn>2076-3417</eissn><abstract>Near-infrared spectroscopy (NIRS) is an optical technique that can measure brain tissue oxygenation and haemodynamics in real-time and at the patient bedside allowing medical doctors to access important physiological information. However, despite this, the use of NIRS in a clinical environment is hindered due to limitations, such as poor reproducibility, lack of depth sensitivity and poor brain-specificity. Time domain NIRS (or TD-NIRS) can resolve these issues and offer detailed information of the optical properties of the tissue, allowing better physiological information to be retrieved. This is achieved at the cost of increased instrument complexity, operation complexity and price. In this review, we focus on brain monitoring clinical applications of TD-NIRS. A total of 52 publications were identified, spanning the fields of neonatal imaging, stroke assessment, traumatic brain injury (TBI) assessment, brain death assessment, psychiatry, peroperative care, neuronal disorders assessment and communication with patient with locked-in syndrome. In all the publications, the advantages of the TD-NIRS measurement to (1) extract absolute values of haemoglobin concentration and tissue oxygen saturation, (2) assess the reduced scattering coefficient, and (3) separate between extra-cerebral and cerebral tissues, are highlighted; and emphasize the utility of TD-NIRS in a clinical context. In the last sections of this review, we explore the recent developments of TD-NIRS, in terms of instrumentation and methodologies that might impact and broaden its use in the hospital.</abstract><cop>Basel</cop><pub>MDPI AG</pub><doi>10.3390/app9081612</doi><orcidid>https://orcid.org/0000-0002-8125-0313</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 2076-3417
ispartof Applied sciences, 2019-04, Vol.9 (8), p.1612
issn 2076-3417
2076-3417
language eng
recordid cdi_doaj_primary_oai_doaj_org_article_ecf69611ed414a3c849209ab68c9a20d
source Publicly Available Content Database
subjects absorption
brain oxygenation
diffuse optics
NIRS
scattering
time-domain
time-resolved
tissue saturation
title Clinical Brain Monitoring with Time Domain NIRS: A Review and Future Perspectives
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-24T23%3A31%3A58IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_doaj_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Clinical%20Brain%20Monitoring%20with%20Time%20Domain%20NIRS:%20A%20Review%20and%20Future%20Perspectives&rft.jtitle=Applied%20sciences&rft.au=Lange,%20Fr%C3%A9d%C3%A9ric&rft.date=2019-04-01&rft.volume=9&rft.issue=8&rft.spage=1612&rft.pages=1612-&rft.issn=2076-3417&rft.eissn=2076-3417&rft_id=info:doi/10.3390/app9081612&rft_dat=%3Cproquest_doaj_%3E2331407905%3C/proquest_doaj_%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c361t-3eecf216942a2b393ffa0b78b38ec360da5c55082ac44010dfca1ef04225c8f33%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2331407905&rft_id=info:pmid/&rfr_iscdi=true