Short-term clinical results of bicruciate-retaining total knee arthroplasty using personalized alignment
Bicruciate-retaining (BCR) prosthesis has been introduced to recreate normal knee movement by preserving both the anterior and posterior cruciate ligaments. However, the use of BCR total knee arthroplasty (TKA) is still debatable because of several disappointing reports. We have been performing BCR...
Saved in:
Published in: | BMC musculoskeletal disorders 2023-12, Vol.24 (1), p.965-965, Article 965 |
---|---|
Main Authors: | , , , , , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Bicruciate-retaining (BCR) prosthesis has been introduced to recreate normal knee movement by preserving both the anterior and posterior cruciate ligaments. However, the use of BCR total knee arthroplasty (TKA) is still debatable because of several disappointing reports. We have been performing BCR TKAs with personalized alignment (PA). This study aimed to reveal the limb alignment and soft tissue balance of FA-BCR TKAs and compare the clinical outcomes of FA-BCR TKAs with those of unicompartmental knee arthroplasty (UKA).
Fifty BCR TKAs and 58 UKAs were included in this study. The joint component gaps of BCR TKA were evaluated intraoperatively and the postoperative hip-knee-ankle (HKA) angle, medial proximal tibial angle (MPTA), and lateral distal femoral angle (LDFA) were measured using full-length standing radiography. The short-term clinical outcomes of BCR TKAs were compared with those of UKA using the scoring system of 2011 Knee Society Scoring (KSS) and the knee injury and osteoarthritis outcome score (KOOS) at an average of 2 years postoperatively (1-4yeras).
The coronal alignment values of PA-BCR TKA were as follows: HKA angle, 177.9° ± 2.3°; MPTA, 85.4° ± 1.9°; and LDFA, 87.5° ± 1.9°. The joint component gaps at flexion angles of 10°, 30°, 60°, and 90° were 11.1 ± 1.2, 10.9 ± 1.4, 10.7 ± 1.3, and 11.2 ± 1.4 mm for the medial compartment and 12.9 ± 1.5, 12.6 ± 1.8, 12.5 ± 1.8 and 12.5 ± 1.7 mm for the lateral compartment, respectively. The patient expectation score and maximum extension angle of PA-BCR TKA were significantly better than those of UKAs.
The short-term clinical outcomes of PA-BCR TKA were comparable or a slightly superior to those of UKAs. |
---|---|
ISSN: | 1471-2474 1471-2474 |