Loading…
Proximal versus Distal Screw Placement for Biceps Tenodesis: A Biomechanical Study
Purpose To assess the maximum and end torque of a fourth-generation composite humerus model with no screw inserted or with a screw inserted in the distal (subpectoral) position or proximal (suprapectoral) position. Methods 24 large-size, fourth-generation composite humeri were randomised to the cont...
Saved in:
Published in: | Journal of orthopaedic surgery (Hong Kong) 2016-08, Vol.24 (2), p.258-261 |
---|---|
Main Authors: | , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Request full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Purpose
To assess the maximum and end torque of a fourth-generation composite humerus model with no screw inserted or with a screw inserted in the distal (subpectoral) position or proximal (suprapectoral) position.
Methods
24 large-size, fourth-generation composite humeri were randomised to the control (n=8), proximal (n=8), or distal (n=8) group. For the latter 2 groups, an 8-mm-head interference screw (7times25 mm) was inserted at 1 cm proximal and 1 cm distal to the superior aspect of the insertion of the pectoralis major tendon, respectively. The maximum and end torque of each humerus was assessed.
Results
Respectively for the control, proximal, and distal groups, the maximum torque was 81.8, 78.7, and 74.3 Nm, and the end torque was 80.7, 78.6, and 71.8 Nm; only the difference between control and distal groups was significant (p=0.005 for maximum torque and p=0.033 for end torque). All fractures in both control and proximal groups involved the distal 1/3 humerus. In the distal group, the fractures involved either the distal 1/3 humerus (n=6) or the screw-hole (n=2); the difference between the 2 types of fracture was not significant in terms of maximum torque (75.7 vs. 70.0, p=0.086) or end torque (75.3 vs. 61.4, p=0.40).
Conclusion
Compared with proximal placement of an interference screw, distal placement decreased the maximum torque (though not significantly) and may increase the risk of proximal humeral fracture. |
---|---|
ISSN: | 1022-5536 2309-4990 |
DOI: | 10.1177/1602400227 |