The phenomenon of concealed conduction in a case of His bundle pacing (HBP)
The phenomenon of concealed conduction in His bundle pacing (HBP) has rarely been reported. We report here a patient who had 2: 1 atrioventricular block and complete left bundle branch block was used because of HBP. The patient developed continuous right bundle branch block after the operation. Afte...
Saved in:
Published in: | Journal of international medical research 2020-02, Vol.48 (2), p.300060520903608-300060520903608 |
---|---|
Main Authors: | , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | |
---|---|
cites | cdi_FETCH-LOGICAL-c481t-f7614d133e94a18875ebb81d6909eff21ea9264ac2e0521e642d22d2046b9b593 |
container_end_page | 300060520903608 |
container_issue | 2 |
container_start_page | 300060520903608 |
container_title | Journal of international medical research |
container_volume | 48 |
creator | Sun, Shuai Zhang, Hong Liu, Xing-Peng |
description | The phenomenon of concealed conduction in His bundle pacing (HBP) has rarely been reported. We report here a patient who had 2: 1 atrioventricular block and complete left bundle branch block was used because of HBP. The patient developed continuous right bundle branch block after the operation. After excluding mechanical damage, we speculate that the mechanism of right bundle branch block in this case was due to concealed conduction. |
doi_str_mv | 10.1177/0300060520903608 |
format | article |
fullrecord | <record><control><sourceid>proquest_doaj_</sourceid><recordid>TN_cdi_doaj_primary_oai_doaj_org_article_f1c773d4452f45b8a68d2ec69fd9f323</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sage_id>10.1177_0300060520903608</sage_id><doaj_id>oai_doaj_org_article_f1c773d4452f45b8a68d2ec69fd9f323</doaj_id><sourcerecordid>2355946822</sourcerecordid><originalsourceid>FETCH-LOGICAL-c481t-f7614d133e94a18875ebb81d6909eff21ea9264ac2e0521e642d22d2046b9b593</originalsourceid><addsrcrecordid>eNp1kd9rFDEQx4Mo9qy--yQLvtSH1fza_HgRtFSvWNCH-hyyyeRuj73kTHYF__tmvVptQUjIMPOZ78xkEHpJ8FtCpHyHGcZY4I5ijZnA6hFaES5ZS6v_MVot4XaJn6Bnpeww5lR09Ck6YRR3giuyQl-ut9ActhDTvt7YpNC4FB3YEfxi-dlNQ_UPsbGNswUWYj2Upp-jH2uqdUPcNGfrj9_ePEdPgh0LvLh9T9H3TxfX5-v26uvny_MPV62rJac2SEG4J4yB5pYoJTvoe0W80FhDCJSA1VRw6yjUyQgITj2tB3PR677T7BRdHnV9sjtzyMPe5l8m2cH8dqS8MTZPgxvBBOKkZJ7zjgbe9coK5Sk4oYPXgVFWtd4ftQ5zvwfvIE7ZjvdE70fisDWb9NNIQgiWSzNntwI5_ZihTGY_FAfjaCOkuRjKuk5zoSit6OsH6C7NOdavqpTikhOFRaXwkXI5lZIh3DVDsFm2bh5uvaa8-neIu4Q_a65AewSK3cDfqv8VvAEcmLE9</addsrcrecordid><sourcetype>Open Website</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2384741806</pqid></control><display><type>article</type><title>The phenomenon of concealed conduction in a case of His bundle pacing (HBP)</title><source>Publicly Available Content Database (Proquest) (PQ_SDU_P3)</source><source>SAGE Open Access</source><source>PubMed Central</source><creator>Sun, Shuai ; Zhang, Hong ; Liu, Xing-Peng</creator><creatorcontrib>Sun, Shuai ; Zhang, Hong ; Liu, Xing-Peng</creatorcontrib><description>The phenomenon of concealed conduction in His bundle pacing (HBP) has rarely been reported. We report here a patient who had 2: 1 atrioventricular block and complete left bundle branch block was used because of HBP. The patient developed continuous right bundle branch block after the operation. After excluding mechanical damage, we speculate that the mechanism of right bundle branch block in this case was due to concealed conduction.</description><identifier>ISSN: 0300-0605</identifier><identifier>EISSN: 1473-2300</identifier><identifier>DOI: 10.1177/0300060520903608</identifier><identifier>PMID: 32056481</identifier><language>eng</language><publisher>London, England: SAGE Publications</publisher><subject>Aged ; Bradycardia - diagnosis ; Bradycardia - etiology ; Bradycardia - physiopathology ; Bradycardia - therapy ; Bundle of His - physiopathology ; Bundle-Branch Block - diagnosis ; Bundle-Branch Block - etiology ; Bundle-Branch Block - physiopathology ; Bundle-Branch Block - therapy ; Cardiac Pacing, Artificial ; Case Report ; Electrocardiography ; Heart Rate - physiology ; Humans ; Male ; Pacemaker, Artificial ; Treatment Outcome</subject><ispartof>Journal of international medical research, 2020-02, Vol.48 (2), p.300060520903608-300060520903608</ispartof><rights>The Author(s) 2020</rights><rights>The Author(s) 2020. This work is licensed under the Creative Commons Attribution – Non-Commercial License https://creativecommons.org/licenses/by-nc/4.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.</rights><rights>The Author(s) 2020 2020 SAGE Publications</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c481t-f7614d133e94a18875ebb81d6909eff21ea9264ac2e0521e642d22d2046b9b593</cites><orcidid>0000-0001-6647-8291</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC7111079/pdf/$$EPDF$$P50$$Gpubmedcentral$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.proquest.com/docview/2384741806?pq-origsite=primo$$EHTML$$P50$$Gproquest$$Hfree_for_read</linktohtml><link.rule.ids>230,314,727,780,784,885,21966,25753,27853,27924,27925,37012,37013,44590,44945,45333,53791,53793</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/32056481$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Sun, Shuai</creatorcontrib><creatorcontrib>Zhang, Hong</creatorcontrib><creatorcontrib>Liu, Xing-Peng</creatorcontrib><title>The phenomenon of concealed conduction in a case of His bundle pacing (HBP)</title><title>Journal of international medical research</title><addtitle>J Int Med Res</addtitle><description>The phenomenon of concealed conduction in His bundle pacing (HBP) has rarely been reported. We report here a patient who had 2: 1 atrioventricular block and complete left bundle branch block was used because of HBP. The patient developed continuous right bundle branch block after the operation. After excluding mechanical damage, we speculate that the mechanism of right bundle branch block in this case was due to concealed conduction.</description><subject>Aged</subject><subject>Bradycardia - diagnosis</subject><subject>Bradycardia - etiology</subject><subject>Bradycardia - physiopathology</subject><subject>Bradycardia - therapy</subject><subject>Bundle of His - physiopathology</subject><subject>Bundle-Branch Block - diagnosis</subject><subject>Bundle-Branch Block - etiology</subject><subject>Bundle-Branch Block - physiopathology</subject><subject>Bundle-Branch Block - therapy</subject><subject>Cardiac Pacing, Artificial</subject><subject>Case Report</subject><subject>Electrocardiography</subject><subject>Heart Rate - physiology</subject><subject>Humans</subject><subject>Male</subject><subject>Pacemaker, Artificial</subject><subject>Treatment Outcome</subject><issn>0300-0605</issn><issn>1473-2300</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2020</creationdate><recordtype>article</recordtype><sourceid>AFRWT</sourceid><sourceid>PIMPY</sourceid><sourceid>DOA</sourceid><recordid>eNp1kd9rFDEQx4Mo9qy--yQLvtSH1fza_HgRtFSvWNCH-hyyyeRuj73kTHYF__tmvVptQUjIMPOZ78xkEHpJ8FtCpHyHGcZY4I5ijZnA6hFaES5ZS6v_MVot4XaJn6Bnpeww5lR09Ck6YRR3giuyQl-ut9ActhDTvt7YpNC4FB3YEfxi-dlNQ_UPsbGNswUWYj2Upp-jH2uqdUPcNGfrj9_ePEdPgh0LvLh9T9H3TxfX5-v26uvny_MPV62rJac2SEG4J4yB5pYoJTvoe0W80FhDCJSA1VRw6yjUyQgITj2tB3PR677T7BRdHnV9sjtzyMPe5l8m2cH8dqS8MTZPgxvBBOKkZJ7zjgbe9coK5Sk4oYPXgVFWtd4ftQ5zvwfvIE7ZjvdE70fisDWb9NNIQgiWSzNntwI5_ZihTGY_FAfjaCOkuRjKuk5zoSit6OsH6C7NOdavqpTikhOFRaXwkXI5lZIh3DVDsFm2bh5uvaa8-neIu4Q_a65AewSK3cDfqv8VvAEcmLE9</recordid><startdate>20200201</startdate><enddate>20200201</enddate><creator>Sun, Shuai</creator><creator>Zhang, Hong</creator><creator>Liu, Xing-Peng</creator><general>SAGE Publications</general><general>Sage Publications Ltd</general><general>SAGE Publishing</general><scope>AFRWT</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>3V.</scope><scope>7X7</scope><scope>7XB</scope><scope>8FI</scope><scope>8FJ</scope><scope>8FK</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>FYUFA</scope><scope>GHDGH</scope><scope>K9.</scope><scope>M0S</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>7X8</scope><scope>5PM</scope><scope>DOA</scope><orcidid>https://orcid.org/0000-0001-6647-8291</orcidid></search><sort><creationdate>20200201</creationdate><title>The phenomenon of concealed conduction in a case of His bundle pacing (HBP)</title><author>Sun, Shuai ; Zhang, Hong ; Liu, Xing-Peng</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c481t-f7614d133e94a18875ebb81d6909eff21ea9264ac2e0521e642d22d2046b9b593</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2020</creationdate><topic>Aged</topic><topic>Bradycardia - diagnosis</topic><topic>Bradycardia - etiology</topic><topic>Bradycardia - physiopathology</topic><topic>Bradycardia - therapy</topic><topic>Bundle of His - physiopathology</topic><topic>Bundle-Branch Block - diagnosis</topic><topic>Bundle-Branch Block - etiology</topic><topic>Bundle-Branch Block - physiopathology</topic><topic>Bundle-Branch Block - therapy</topic><topic>Cardiac Pacing, Artificial</topic><topic>Case Report</topic><topic>Electrocardiography</topic><topic>Heart Rate - physiology</topic><topic>Humans</topic><topic>Male</topic><topic>Pacemaker, Artificial</topic><topic>Treatment Outcome</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Sun, Shuai</creatorcontrib><creatorcontrib>Zhang, Hong</creatorcontrib><creatorcontrib>Liu, Xing-Peng</creatorcontrib><collection>SAGE Open Access</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>ProQuest Central (Corporate)</collection><collection>Health & Medical Collection</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>Hospital Premium Collection</collection><collection>Hospital Premium Collection (Alumni Edition)</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>ProQuest Central (Alumni)</collection><collection>ProQuest Central</collection><collection>ProQuest Central Essentials</collection><collection>ProQuest Central</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central</collection><collection>Health Research Premium Collection</collection><collection>Health Research Premium Collection (Alumni)</collection><collection>ProQuest Health & Medical Complete (Alumni)</collection><collection>Health & Medical Collection (Alumni Edition)</collection><collection>Publicly Available Content Database (Proquest) (PQ_SDU_P3)</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><collection>Directory of Open Access Journals</collection><jtitle>Journal of international medical research</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Sun, Shuai</au><au>Zhang, Hong</au><au>Liu, Xing-Peng</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>The phenomenon of concealed conduction in a case of His bundle pacing (HBP)</atitle><jtitle>Journal of international medical research</jtitle><addtitle>J Int Med Res</addtitle><date>2020-02-01</date><risdate>2020</risdate><volume>48</volume><issue>2</issue><spage>300060520903608</spage><epage>300060520903608</epage><pages>300060520903608-300060520903608</pages><issn>0300-0605</issn><eissn>1473-2300</eissn><abstract>The phenomenon of concealed conduction in His bundle pacing (HBP) has rarely been reported. We report here a patient who had 2: 1 atrioventricular block and complete left bundle branch block was used because of HBP. The patient developed continuous right bundle branch block after the operation. After excluding mechanical damage, we speculate that the mechanism of right bundle branch block in this case was due to concealed conduction.</abstract><cop>London, England</cop><pub>SAGE Publications</pub><pmid>32056481</pmid><doi>10.1177/0300060520903608</doi><orcidid>https://orcid.org/0000-0001-6647-8291</orcidid><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0300-0605 |
ispartof | Journal of international medical research, 2020-02, Vol.48 (2), p.300060520903608-300060520903608 |
issn | 0300-0605 1473-2300 |
language | eng |
recordid | cdi_doaj_primary_oai_doaj_org_article_f1c773d4452f45b8a68d2ec69fd9f323 |
source | Publicly Available Content Database (Proquest) (PQ_SDU_P3); SAGE Open Access; PubMed Central |
subjects | Aged Bradycardia - diagnosis Bradycardia - etiology Bradycardia - physiopathology Bradycardia - therapy Bundle of His - physiopathology Bundle-Branch Block - diagnosis Bundle-Branch Block - etiology Bundle-Branch Block - physiopathology Bundle-Branch Block - therapy Cardiac Pacing, Artificial Case Report Electrocardiography Heart Rate - physiology Humans Male Pacemaker, Artificial Treatment Outcome |
title | The phenomenon of concealed conduction in a case of His bundle pacing (HBP) |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-03T10%3A27%3A20IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_doaj_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=The%20phenomenon%20of%20concealed%20conduction%20in%20a%20case%20of%20His%20bundle%20pacing%20(HBP)&rft.jtitle=Journal%20of%20international%20medical%20research&rft.au=Sun,%20Shuai&rft.date=2020-02-01&rft.volume=48&rft.issue=2&rft.spage=300060520903608&rft.epage=300060520903608&rft.pages=300060520903608-300060520903608&rft.issn=0300-0605&rft.eissn=1473-2300&rft_id=info:doi/10.1177/0300060520903608&rft_dat=%3Cproquest_doaj_%3E2355946822%3C/proquest_doaj_%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c481t-f7614d133e94a18875ebb81d6909eff21ea9264ac2e0521e642d22d2046b9b593%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2384741806&rft_id=info:pmid/32056481&rft_sage_id=10.1177_0300060520903608&rfr_iscdi=true |