Manganese Dynamics in Mouse Brain After Systemic MnCl2 Administration for Activation-Induced Manganese-Enhanced MRI
Activation-induced manganese-enhanced MRI (AIM-MRI) is an attractive tool for non-invasively mapping whole brain activities. Manganese ions (Mn 2+ ) enter and accumulate in active neurons via calcium channels. Mn 2+ shortens the longitudinal relaxation time (T1) of H + , and the longitudinal relaxat...
Saved in:
Published in: | Frontiers in neural circuits 2021-12, Vol.15, p.787692-787692 |
---|---|
Main Authors: | , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Activation-induced manganese-enhanced MRI (AIM-MRI) is an attractive tool for non-invasively mapping whole brain activities. Manganese ions (Mn
2+
) enter and accumulate in active neurons via calcium channels. Mn
2+
shortens the longitudinal relaxation time (T1) of H
+
, and the longitudinal relaxation rate R1 (1/T1) is proportional to Mn
2+
concentration. Thus, AIM-MRI can map neural activities throughout the brain by assessing the R1 map. However, AIM-MRI is still not widely used, partially due to insufficient information regarding Mn
2+
dynamics in the brain. To resolve this issue, we conducted a longitudinal study looking at manganese dynamics after systemic administration of MnCl
2
by AIM-MRI with quantitative analysis. In the ventricle, Mn
2+
increased rapidly within 1 h, remained high for 3 h, and returned to near control levels by 24 h after administration. Microdialysis showed that extracellular Mn returned to control levels by 4 h after administration, indicating a high concentration of extracellular Mn
2+
lasts at least about 3 h after administration. In the brain parenchyma, Mn
2+
increased slowly, peaked 24–48 h after administration, and returned to control level by 5 days after a single administration and by 2 weeks after a double administration with a 24-h interval. These time courses suggest that AIM-MRI records neural activity 1–3 h after MnCl
2
administration, an appropriate timing of the MRI scan is in the range of 24–48 h following systemic administration, and at least an interval of 5 days or a couple of weeks for single or double administrations, respectively, is needed for a repeat AIM-MRI experiment. |
---|---|
ISSN: | 1662-5110 1662-5110 |
DOI: | 10.3389/fncir.2021.787692 |