Loading…

Spontaneous long-term and urethane induced hippocampal EEG power, activity and temperature data from mice lacking the Cav3.2 voltage-gated Ca2+ channel

This article provides raw relative electroencephalographic (EEG) power, temperature and activity data from controls and Cav3.2 deficient mice. Radiotransmitter implantation was carried out in male experimental mice under ketamine/xylazine narcosis. Following a recovery period, radiotelemetric EEG re...

Full description

Saved in:
Bibliographic Details
Published in:Data in brief 2021-06, Vol.36, p.107027-107027, Article 107027
Main Authors: Papazoglou, Anna, Arshaad, Muhammad Imran, Siwek, Magdalena Elisabeth, Henseler, Christina, Daubner, Johanna, Ehninger, Dan, Hescheler, Jürgen, Broich, Karl, Weiergräber, Marco
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:This article provides raw relative electroencephalographic (EEG) power, temperature and activity data from controls and Cav3.2 deficient mice. Radiotransmitter implantation was carried out in male experimental mice under ketamine/xylazine narcosis. Following a recovery period, radiotelemetric EEG recordings from the hippocampal CA1 region were obtained under spontaneous 24 h long-term conditions and post urethane injection. Relative EEG power values (%) for 2 s epochs were analysed for the following frequency ranges: delta 1 (δ1, 0.5–4 Hz), delta 2 (δ2, 1–4 Hz), theta 1 (θ1, 4–8 Hz), theta 2 (θ2, 4–12 Hz), alpha (α, 8–12 Hz), sigma (σ, 12–16 Hz), beta 1 (β1, 12–30 Hz), beta 2 (β2, 16–24 Hz), beta 3 (β3, 16–30 Hz), gamma low (γlow, 30–50 Hz), gamma mid (γmid, 50–70 Hz), gamma high (γhigh, 70–100 Hz), gamma ripples (γripples, 80–200 Hz), and gamma fast ripples (γfastripples, 200–500 Hz). In addition, subcutaneous temperature and relative activity data were analysed for both the light and dark cycle of two long-term recordings. The same type of data was obtained post urethane injection. Detailed information is provided for the age and body weight of the experimental animals, the technical specifications of the radiofrequency transmitter, the stereotaxic coordinates for the intracerebral, deep and epidural, surface EEG electrodes, the electrode features, the filtering and sampling characteristics, the analysed EEG frequency bands and the data acquisition parameters. EEG power data, temperature and activity data are available at MENDELEY DATA (doi:10.17632/x53km5sby6.1, URL: http://dx.doi.org/10.17632/x53km5sby6.1). Raw EEG data are available at zenodo (https://zenodo.org/).
ISSN:2352-3409
2352-3409
DOI:10.1016/j.dib.2021.107027